DV007004 Microchip Technology, DV007004 Datasheet - Page 48

PROGRAMMER UNIVERSAL PM3

DV007004

Manufacturer Part Number
DV007004
Description
PROGRAMMER UNIVERSAL PM3
Manufacturer
Microchip Technology
Series
MPLAB&reg PM3r
Type
Universalr
Datasheets

Specifications of DV007004

Contents
MPLAB PM3 Programming Unit, Cables, Power Supply and IDE
Positions/sockets
1
Ic Product Type
Programmer, Universal
Supported Families
PICmicro, DsPIC30F
Kit Contents
LCD, ICSP Support, 40-pin Socket, Digital/Multimedia Card Slot
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Microchip's PICmicro devices including dsPIC30F
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
PICmicro And DsPIC30F DSC Devices
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DV007004
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
DV007004
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
DV007004 (MPLAB PM3)
Manufacturer:
MICROCHIP
Quantity:
12 000
4.6
DS51464C-page 42
VERIFYING THE PROGRAMMING
®
4.5.5
You are ready to program your device. Select Programmer>Program to program the
entire device (i.e., all of the program memory, Configuration bits, etc.).
If you want to program selectively (e.g., part of program memory, only Configuration
bits), select Programmer>Settings to open the Programmer Settings dialog. Click the
Memory Ranges tab (see Table 4-1 and Section 7.5.1 “Memory Ranges Tab”) and
select the options for programming. Areas that are grayed out are not available on the
device. Click OK. Then, select Programmer>Program to program the device. The
memory area corresponding to the checked boxes will be programmed.
TABLE 4-1:
After MPLAB PM3 programs a device, it automatically performs a verify operation and
displays any errors found. An additional verify operation may be done via selecting
Programmer>Verify.
Click Programmer>Verify to verify that the programming on the device matches the
program memory, Configuration bits, ID locations, EEPROM and calibration memory
values in MPLAB IDE and in the Settings dialog and Configuration Bits dialog.
If there are more errors than expected and those errors claim that the bad data is all
zeros (0000), the socket module might not be seated properly. Remove and reseat the
socket module. It is always a good practice to insert a known blank device and do a
Blank Check whenever the socket module is changed.
Program Memory Start Address
Program Memory End Address
Reset Addresses
Program Memory
Configuration Bits
ID Location
EEPROM Data
Calibration Memory
Erase All Before Program
Note:
Programming the Device
A verify is automatically done after a program command.
Option
MEMORY RANGES TAB OPTIONS
memory.
memory.
Click this button to reset the program memory
addresses.
Program Memory. The program memory range is
determined by the program memory start and end
address fields.
Select this check box if configuration memory is to
be programmed.
programmed.
is to be programmed.
Select this check box if calibration memory to be
programmed.
Select this check box if the device is to be erased
before programming.
Type the start address for the range of program
Type the end address for the range of program
Select this check box if you want to program
Select this check box if the ID location is to be
Select this check box if the EEPROM data memory
Description
© 2006 Microchip Technology Inc.

Related parts for DV007004