AT89C51IC2-SLSUM Atmel, AT89C51IC2-SLSUM Datasheet - Page 98

IC 8051 MCU FLASH 32K 44PLCC

AT89C51IC2-SLSUM

Manufacturer Part Number
AT89C51IC2-SLSUM
Description
IC 8051 MCU FLASH 32K 44PLCC
Manufacturer
Atmel
Series
89Cr
Datasheet

Specifications of AT89C51IC2-SLSUM

Core Processor
8051
Core Size
8-Bit
Speed
60MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
34
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
44-PLCC
Processor Series
AT89x
Core
8051
Data Bus Width
8 bit
Data Ram Size
1280 B
Interface Type
UART, SPI, TWI
Maximum Clock Frequency
60 MHz
Number Of Programmable I/os
34
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
- 40 C
For Use With
AT89OCD-01 - USB EMULATOR FOR AT8XC51 MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51IC2-SLSUM
Manufacturer:
Atmel
Quantity:
10 000
98
(SSCS)
Status
Code
C0h
C8h
AT89C51IC2
Status of the 2-wire bus and
been transmitted (AA=0); ACK
Data byte in SSDAT has been
Last data byte in SSDAT has
transmitted; NOT ACK has
has been received
2-wire hardware
been received
Table 72.
(SSCS)
Status
Code
F8h
00h
No SSDAT action or
No SSDAT action or
No SSDAT action or
No SSDAT action or
No SSDAT action or
No SSDAT action or
No SSDAT action
No SSDAT action
To/from SSDAT
Status of the 2-wire
Bus error due to an
Miscellaneous status
No relevant state
Application Software Response
bus and 2-wire
illegal START or
STOP condition
available; SI= 0
information
hardware
STA
0
0
1
1
0
0
1
1
To SSCON
No SSDAT
No SSDAT
STO
Application Software Response
To/from
SSDAT
action
action
0
0
0
0
0
0
0
0
SI
0
0
0
0
0
0
0
0
STA STO
AA
0
0
1
0
1
0
1
0
1
No SSCON action
To SSCON
Next Action Taken By 2-wire Software
Switched to the not addressed slave mode; no
recognition of own SLA or GCA
Switched to the not addressed slave mode; own
SLA will be recognised; GCA will be recognised if
GC=logic 1
Switched to the not addressed slave mode; no
recognition of own SLA or GCA. A START
condition will be transmitted when the bus
becomes free
Switched to the not addressed slave mode; own
SLA will be recognised; GCA will be recognised if
GC=logic 1. A START condition will be transmitted
when the bus becomes free
Switched to the not addressed slave mode; no
recognition of own SLA or GCA
Switched to the not addressed slave mode; own
SLA will be recognised; GCA will be recognised if
GC=logic 1
Switched to the not addressed slave mode; no
recognition of own SLA or GCA. A START
condition will be transmitted when the bus
becomes free
Switched to the not addressed slave mode; own
SLA will be recognised; GCA will be recognised if
GC=logic 1. A START condition will be transmitted
when the bus becomes free
1
SI
0
AA
X
Next Action Taken By 2-wire
Software
Wait or proceed current transfer
Only the internal hardware is
affected, no STOP condition is
sent on the bus. In all cases,
the bus is released and STO is
reset.
4301D–8051–02/08

Related parts for AT89C51IC2-SLSUM