LM13700MX/NOPB National Semiconductor, LM13700MX/NOPB Datasheet - Page 15

IC AMP DUAL OP TRANSCOND 16-SOIC

LM13700MX/NOPB

Manufacturer Part Number
LM13700MX/NOPB
Description
IC AMP DUAL OP TRANSCOND 16-SOIC
Manufacturer
National Semiconductor
Datasheet

Specifications of LM13700MX/NOPB

Amplifier Type
Transconductance
Number Of Circuits
2
Output Type
Push-Pull
Slew Rate
50 V/µs
Gain Bandwidth Product
2MHz
Current - Input Bias
1µA
Voltage - Input Offset
300µV
Current - Supply
2.6mA
Current - Output / Channel
650µA
Voltage - Supply, Single/dual (±)
10 V ~ 36 V, ±5 V ~ 18 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
-3db Bandwidth
-
Other names
*LM13700MX
*LM13700MX/NOPB
LM13700MX

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM13700MX/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM13700MX/NOPB
0
Company:
Part Number:
LM13700MX/NOPB
Quantity:
40 000
Voltage Controlled Filters
Voltage Controlled Oscillators
The classic Triangular/Square Wave VCO of Figure 15 is
one of a variety of Voltage Controlled Oscillators which may
be built utilizing the LM13700. With the component values
shown, this oscillator provides signals from 200 kHz to below
2 Hz as I
amplitudes are set by I
input voltage must be less than 5V to prevent zenering the
inputs.
A few modifications to this circuit produce the ramp/pulse
VCO of Figure 16. When V
C
is varied from 1 mA to 10 nA. The output
A
x R
A
O2
. Note that the peak differential
is high, I
FIGURE 14. Voltage Controlled State Variable Filter
F
is added to I
(Continued)
C
to
15
increase amplifier A1’s bias current and thus to increase the
charging rate of capacitor C. When V
zero and the capacitor discharge current is set by I
The VC Lo-Pass Filter of Figure 11 may be used to produce
a high-quality sinusoidal VCO. The circuit of Figure 16 em-
ploys two LM13700 packages, with three of the amplifiers
configured as lo-pass filters and the fourth as a limiter/
inverter. The circuit oscillates at the frequency at which the
loop phase-shift is 360˚ or 180˚ for the inverter and 60˚ per
filter stage. This VCO operates from 5 Hz to 50 kHz with less
than 1% THD.
O2
is low, I
00798121
www.national.com
F