B57364S209M EPCOS Inc, B57364S209M Datasheet - Page 3

CURRENT LIMITER INRSH 2 OHM 20%

B57364S209M

Manufacturer Part Number
B57364S209M
Description
CURRENT LIMITER INRSH 2 OHM 20%
Manufacturer
EPCOS Inc
Type
NTCr
Datasheets

Specifications of B57364S209M

Lead Spacing
0.295" (7.50mm)
R @ 25°c
2.0 Ohm
Current - Steady State Max
12A
Tolerance
±20%
Diameter
0.825" (21mm)
Thermistor Type
NTC
Resistance
2ohm
Beta Value (k)
2900
Svhc
No SVHC (18-Jun-2010)
Beta Value Lower Limit Temperature
25°C
Body Diameter
21mm
Current Max
12A
Lead Length
32mm
Termination Style
Radial
Operating Temperature Range
- 55 C to + 170 C
Current Rating
12 Amps
Power Rating
5.1 W
Mounting Style
Through Hole
Pin Count
2
Thermal Time Constant
100s
Percentage Of Resistance Tolerance @ 25c
±20
Accuracy
±3
Product Length (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Thermistor Tolerance
± 20%
Thermistor Case Style
Radial Leaded
No. Of Pins
2
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
R @ Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
495-4114
B57364S 209M
B57364S0209M000
B57364S0209M000
Q1848236
Q3180393
Q3247542
Reliability data
Test
Storage in
dry heat
Storage in damp
heat, steady state
Rapid temperature
cycling
Endurance
Cyclic
endurance
Transient
load
Note
Please read Cautions and warnings and
Important notes at the end of this document.
Inrush current limiters
ICLs
The self-heating of a thermistor during operation depends on the load applied and the
applicable dissipation factor.
When loaded with maximum allowable current/power and the specified dissipation factor is
taken as a basis, the NTC thermistor may reach a mean temperature of up to 250 C.
The heat developed during operation will also be dissipated through the lead wires. So the
contact areas, too, may become quite hot at maximum load.
When mounting NTC thermistors you have to ensure that there is an adequate distance
between the thermistor and all parts which are sensitive to heat or combustible.
Standard
IEC
60068-2-2
IEC
60068-2-78
IEC
60068-2-14
Test conditions
Storage at upper
category temperature
T: 170 C
t: 1000 h
Temperature of air: 40 C
Relative humidity of air: 93%
Duration: 21 days
Lower test temperature:
Upper test temperature: 170 C
Number of cycles: 10
I = I
t: 1000 h
I = I
On-time = 1 min
Cooling time = 6 min
Capacitance = C
Number of cycles: 1000
max
max
, 1000 cycles
Page 3 of 15
test
55 C
(typical)
< 10%
< 5%
< 10%
< 10%
< 10%
< 5%
R
25
/R
25
Remarks
No visible
damage
No visible
damage
No visible
damage
No visible
damage
No visible
damage
No visible
damage
B57364
S364

Related parts for B57364S209M