E3X-DA11-S Omron, E3X-DA11-S Datasheet - Page 16

no-image

E3X-DA11-S

Manufacturer Part Number
E3X-DA11-S
Description
RED LED NPN PREWIRE PTUNE
Manufacturer
Omron
Series
E3X-DA-Sr
Datasheet

Specifications of E3X-DA11-S

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E3XDA11S
Industry Leading Two Amplifiers Loaded in a Small Body
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
Simpler Digital Fiber Sensors
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
High-speed and High-resolution Analog Output Supports Wide Variety of Applications
Analog Control Output
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Area Output Function Area Judgment Is
Possible
Only one sensor is enough for area judgment for height or others that
has required multiple sensors.
Setting two threshold values allows easy output inside and outside
range.
Remote Input Function Sensors Controlled from Outside
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites
OMRON’s unique algorithm is equipped to
distinguish dust or dirt and the change of
workpieces. Automatic correction of threshold
values by sensors in accordance with changes
prevents malfunctions and improves the
operating rates of machines. The ATC function
is especially effective for the applications that
require high-resolution detection.
Models available for a wide variety of applications at manufacturing sites
. . . . Advanced, Twin-output Models
. . . . Advanced ATC Models
ON/OFF
Analog
Incident level
(digital value)
Fixed Threshold Value Method (Conventional Models)
. . . . Simple & Easy Single-function Models
Output
2000
ON
OFF
20mm
Malfunction
High-speed and High Resolution
Detection modes can be switched in accordance with applications.
High-speed response of 80 s (super-high-speed mode) supports the
positioning controls that require high-speed control.
Adjustment is required
. . . . Advanced, External-
Sheet Displacement
Area Output
Incident
level
10mm
2000
1000
Output
OFF
ON
input Models
1800
Threshold value
set as an
absolute value
Time
. . . . 2-channel models
2-channel models
E3X-MDA
Incident level
Corrected Threshold Value Method (ATC Models)
(digital value)
Output
2000
ON
OFF
Time
Threshold
value 2
Threshold
value 1
Threshold value is corrected every 30 seconds *
Current value
*
Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.
Malfunctions are prevented
Operation mode
selection switch
E3X-DA-S/MDA
Key lock switch
. . . . Advanced Analog
Threshold value teaching
TEACH key
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
Tablet length detection
Threshold value
Liquid crystal board installation and alignment check
Sticker detection
Output Models
10%
UP/DOWN keys
Threshold value adjustment
Threshold value
set as a relative
value
Time
2

Related parts for E3X-DA11-S