EVAL-ADF7012EB1 Analog Devices Inc, EVAL-ADF7012EB1 Datasheet - Page 18

no-image

EVAL-ADF7012EB1

Manufacturer Part Number
EVAL-ADF7012EB1
Description
BOARD EVALUATION FOR EB1 ADF7012
Manufacturer
Analog Devices Inc
Datasheets

Specifications of EVAL-ADF7012EB1

Module/board Type
Evaluation Board
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
ADF7020 928MHz
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
ADF7012
Setting Tuning Sensitivity Value
The tuning sensitivity or kV is usually denoted in MHz/V and is
required for the loop filter design. It refers to the amount that a
change of a volt in the voltage applied to VCO
the output frequency. Typical data for the ADF7012 over a
frequency range is shown.
Charge-Pump Current
The charge-pump current allows the loop filter bandwidth to be
changed using the registers. The loop bandwidth reduces as the
charge pump current is reduced and vice versa.
Selecting Loop Filter Bandwidth
Data Rate
The loop filter bandwidth should usually be at two to three
times the data rate. This ensures that the PLL has ample time
to jump between the mark and space frequencies.
ACP
In the case where the ACP specifications are difficult to meet,
the loop filter bandwidth can be reduced further to reduce the
phase noise at the adjacent channel. The filter rolls off at 20 dB
per decade.
Spurious Levels
In the case where the output power is quite high, a reduced loop
filter bandwidth reduces the spurious levels even further, and
provides additional margin on the specification.
The following sections provide examples of loop filter designs
for typical applications in specific frequencies.
120
100
80
60
40
20
0
200
300
Figure 37. kV vs. VCO Frequency
400
500
FREQUENCY (MHz)
600
700
800
IN
900
pin, changes
1000
1100
Rev. 0 | Page 18 of 28
PA MATCHING
The ADF7012 exhibits optimum performance in terms of
transmit power and current consumption only if the RF output
port is properly matched to the antenna impedance.
ZOPT_PA depends primarily on the required output power,
and the frequency range. Selecting the optimum ZOPT_PA
helps to minimize the current consumption. This data sheet
contains a number of matching networks for common
frequency bands. Under certain conditions it is recommended
to obtain a suitable ZOPT_PA value by means of a load-pull
measurement.
The impedance matching values provided in the next section
are for 50 Ω environments. An additional matching network
may be required after the harmonic filter to match to the
antenna impedance. This can be incorporated into the filter
design itself in order to reduce external components.
TRANSMIT PROTOCOL AND CODING
CONSIDERATIONS
A dc-free preamble pattern such as 10101010… is recom-
mended for FSK/ASK/OOK demodulation. Preamble patterns
with longer run-length constraints such as 11001100…. can also
be used. However, this can result in a longer synchronization
time of the received bit stream in the chosen receiver.
PREAMBLE
ANTENNA
Figure 39. Typical Format of a Transmit Protocol
Figure 38. ADF7012 with Harmonic Filter
WORD
SYNC
LPF
FIELD
ID
ZOPT_PA
DV
DD
DATA FIELD
RF
OUT
PA
CRC