ATA5279P-PLQW Atmel, ATA5279P-PLQW Datasheet - Page 18

IC ANTENNA DVR SIX-FOLD 48QFN

ATA5279P-PLQW

Manufacturer Part Number
ATA5279P-PLQW
Description
IC ANTENNA DVR SIX-FOLD 48QFN
Manufacturer
Atmel
Datasheet

Specifications of ATA5279P-PLQW

Rf Type
PEG, TPMS
Frequency
125kHz
Features
RSSI Equipped
Package / Case
48-VQFN Exposed Pad, 48-HVQFN, 48-SQFN, 48-DHVQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA5279P-PLQW
Manufacturer:
ATMEL
Quantity:
3 500
Part Number:
ATA5279P-PLQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
3.9
3.9.1
18
Control Logic
Atmel ATA5279
Modulator Stage
The internal control logic handles all information coming from the SPI and controls the power
stages. Diagnostic information is also collected and evaluated here.
The modulator stage controls the coil drivers. It gets all necessary information from the com-
mand buffer. That is:
When a modulator operation is started by an SPI command, the data in the buffer is processed
in the order it arrives via SPI, command by command. The time for this data processing
depends on the command itself and, if LF transmissions are involved, the amount and length
of the data bits.
Table 3-5
Table 3-5.
Note:
• Which coil to drive
• Which current to maintain in this coil/which diagnosis switch to close (in diagnosis mode)
• Which baud rate to use for LF data transmission
• What kind of transmission (i.e., data or carrier)
• LF data itself (respectively the on-time when a carrier is to be transmitted)
Select Coil Curr.
Send LF Carrier
Send LF Data
Select Driver
Command
Table 3-5
decoding or processing time. This is done simultaneous, so that two commands can be exe-
cuted seamlessly.
lists the timings for the driver-related commands.
Execution Durations of Driver-related Commands
lists the duration of command execution for the different commands and not the
N
Dur. [LF per.]
T
2
(32 / 22)
< 1
64
{32 / 22}
Comment
During the first 32 periods, the actual driver is stopped in order
to decay any oscillation in the coil. Then the switching itself is
performed and another 32 periods waiting time is started in
order to wait for the new driver to reach its operation point
The switching time of internal references takes less than 1LF
period. Note that there will always be an interruption in a
telegram if the coil current is changed between two transmission
commands
The duration of this command depends on the selected data
rate (3.9kbit/s, i.e. 32 periods/LF bit, or 5.7kbit/s, i.e.,
22 periods/LF bit) and the amount of nibbles N (2LF data bits) to
be transmitted
The duration of this command depends on the selected data
rate (see also above) and the carrier duration T
9125L–RKE–03/11

Related parts for ATA5279P-PLQW