MPX5700DP Freescale Semiconductor, MPX5700DP Datasheet - Page 2

SENSOR DIFF PRESS 101.5 PSI MAX

MPX5700DP

Manufacturer Part Number
MPX5700DP
Description
SENSOR DIFF PRESS 101.5 PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPX5700r
Datasheet

Specifications of MPX5700DP

Pressure Type
Differential
Operating Pressure
0 ~ 101.5 PSI
Port Size
Male, 0.194" (4.9276mm) Tube
Output
0.2 ~ 4.7V
Accuracy
±2.5%
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP Dual Ports
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
7 mA
Output Voltage
4.7 V
Shutdown
No
Operating Pressure Range
0 To 700kPa
Connection Size
4.928mm
Sensitivity, V/p
6.4mV/kPa
Sensor Case Style
SIP
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPX5700DP
Manufacturer:
FREESCALE
Quantity:
2 000
Part Number:
MPX5700DP
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPX5700DP
0
MPX5700
2
Operating Characteristics
Table 1. Operating Characteristics
required to meet electrical specifications.)
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range.
3. Offset (V
4. Full Scale Output (V
5. Full Scale Span (V
6. Accuracy (error budget) consists of the following:
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
8. Warm-up Time is defined as the time required for the device to meet the specified output voltage after the pressure has been stabilized.
Pressure Range
Supply Voltage
Supply Current
Zero Pressure Offset
Full Scale Output
Full Scale Span
Accuracy
Sensitivity
Response Time
Output Source Current at Full Scale Output
Warm-Up Time
minimum rated pressure.
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0° to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0° to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
specified step change in pressure.
Pressure
(6)
off
) is defined as the output voltage at the minimum rated pressure.
(2)
(8)
(5)
(7)
(1)
(4)
(3)
FSS
FSO
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
) is defined as the output voltage at the maximum or full rated pressure.
Characteristic
(
V
S
= 5.0 Vdc, T
Gauge, Differential: MPX5700D
Gauge, Differential (0 to 85°C)
A
Absolute: MPX5700A
= 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
Absolute (0 to 85°C)
(0 to 85°C)
(0 to 85°C)
(0 to 85°C)
Symbol
V
V
P
V/P
V
I
V
FSO
I
FSS
t
O+
OP
O
off
R
S
0.088
0.184
4.587
Min
4.75
15
0
FSS
Typ
5.0
7.0
0.2
4.7
4.5
6.4
1.0
0.1
, at 25°C.
20
Freescale Semiconductor
Max
0.313
0.409
4.813
5.25
±2.5
700
700
10
Sensors
mV/kPa
%V
mAdc
mAdc
Unit
kPa
Vdc
Vdc
Vdc
Vdc
ms
ms
FSS

Related parts for MPX5700DP