MPX4100AP
Manufacturer Part Number
MPX4100AP
Description
SENSOR ABS PRESS 15.2 PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPX4100r
Datasheet
1.MPXA4100A6U.pdf
(13 pages)
Specifications of MPX4100AP
Pressure Type
Absolute
Operating Pressure
2.9 ~ 15.2 PSI
Port Size
Male, 0.194" (4.9276mm) Tube
Output
0 ~ 4.9V
Voltage - Supply
4.85 V ~ 5.35 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5.1 V
Output Voltage
4.87 V to 5.032 V
Operating Pressure Range
20 To 105kPa
Connection Size
4.928mm
Sensitivity, V/p
54mV/kPa
Supply Current
7mA
Sensor Case Style
SIP
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MPX4100AP
Manufacturer:
DATEL
Quantity:
392
MPX4100A
6
Nominal Transfer Value:
Pressure
Pressure Error Band
Transfer Function (MPX4100A)
Temperature Error Band
Temperature
Factor
Error
-1.0
-2.0
-3.0
3.0
2.0
1.0
0.0
4.0
3.0
2.0
1.0
0.0
NOTE: The Temperature Multiplier is a linear response from 0°C to-40°C and from 85°C to 125°C.
V
± (Pressure Error x Temp. Factor x 0.01059 x V
V
out
S
= 5.1 V ± 0.25 Vdc
= V
-40
S
(P x 0.01059 - 0.1518)
20
-20
Error Limits for Pressure
40
0
MPX4100A Series
60
20
Temperature in °C
Temp
- 40
0 to 85
+125
80
40
100
Multiplier
60
S
)
3
1
3
20 to 105 (kPa)
120
Pressure
80
100
Pressure (in kPa)
Error (Max)
±1.5 (kPa)
120
140
Freescale Semiconductor
Sensors