TCS3414CS TAOS, TCS3414CS Datasheet - Page 24

Photodiodes TriColor Sensor RGB, Clear Ch

TCS3414CS

Manufacturer Part Number
TCS3414CS
Description
Photodiodes TriColor Sensor RGB, Clear Ch
Manufacturer
TAOS
Type
Digital Color Light Sensorr
Datasheet

Specifications of TCS3414CS

Peak Wavelength
470 nm
Maximum Rise Time
300 ns
Maximum Fall Time
300 ns
Package / Case
Chipscale-6
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TCS3414CS
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
TCS3404CS, TCS3414CS
DIGITAL COLOR LIGHT SENSORS
TAOS068 − FEBRUARY 2009
Synchronization
24
Copyright E 2009, TAOS Inc.
INTERRUPT
There are two basic modes of operation for controlling synchronization: (1) internally timed, and (2) externally
timed. Internally-timed integration cycles can either be continuous back-to-back conversions or can be
externally triggered as a single event using the SYNC pin. Externally-timed integrations can be controlled by
setting and clearing the ADC Enable in the Control Register using the serial interface, or by one or more pulses
input to the SYNC pin. Internally-timed integration cycle times are dependent on the PARAM field value and the
internal clock frequency. Nominal integration times and respective scaling between integration times scale
proportionally as shown in the PARAM field in Table 5. See Operating Characteristics Table notes for detailed
information regarding how the scale values were obtained.
If a particular integration time period is required that is not listed in the PARAM Integration Time field value, then
the manual timing control feature can be used to manually start and stop the integration time period by setting
INTEG_MODE=01b. Manual integration is performed as follows:
1. Disable ADC_EN (= 0) before initiating a manual integration cycle
2. Clear and enable INTR before each cycle
3. Write 01b to INTEG_MODE field
4. Set ADC_EN (= 1) to start integration
5. Clear ADC_EN ( = 0) to stop integration
6. Read channel data
ADC_EN
Figure 20. Manual Integration (INTEG_MODE 01b)
APPLICATION INFORMATION: SOFTWARE
A
r
length of time that ADC_EN = 1
Time duration determined by
www.taosinc.com
Integration Period
B
r
The LUMENOLOGY r Company

Related parts for TCS3414CS