TCS3414CS TAOS, TCS3414CS Datasheet - Page 29

Photodiodes TriColor Sensor RGB, Clear Ch

TCS3414CS

Manufacturer Part Number
TCS3414CS
Description
Photodiodes TriColor Sensor RGB, Clear Ch
Manufacturer
TAOS
Type
Digital Color Light Sensorr
Datasheet

Specifications of TCS3414CS

Peak Wavelength
470 nm
Maximum Rise Time
300 ns
Maximum Fall Time
300 ns
Package / Case
Chipscale-6
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TCS3414CS
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
// Synchronize one integration cycle
// Synchronize N number of SYNC IN pulses
The LUMENOLOGY r Company
A synchronization input (SYNC IN) is supported to precisely start/stop sensor integration and synchronize with
the light source. The TIMING Register (01h) provides two synchronization modes of operation. The first mode
of operation synchronizes the SYNC IN pin for one integration cycle as specified in the Timing Register (01h).
When the rising edge of the signal is detected, the TCS3404/14 begins integration. The second mode
accumulates a specified number of SYNC IN pulses (see Timing Register) in which the minimum pulse width
is 50 μs. A pulse counter is used to count the rising and falling edges of the pulse(s) and precisely integrate the
light level when the SYNC IN pulse is high.
The following pseudo code illustrates a procedure for reading the TCS3404/14 device using the synchronization
feature:
// See ”Basic Operation” to power−on and start device
// See ”Configuring the Timing Register” to setup environment
Address = 0x39
Command = 0x81
Data = 0x21
//External SYNC IN pulse initiates 100ms integration
Sleep (100)
// See ”Basic Operation” to read Data Registers using Byte or Word Protocol
// See ”Basic Operation” to power−on and start device
// See ”Configuring the Timing Register” to setup environment
Address = 0x39
Command = 0x81
Data = 0x30
//External SYNC IN pulse synchronizes integration
// See ”Basic Operation” to read Data Registers using Byte or Word Protocol
APPLICATION INFORMATION: SOFTWARE
r
www.taosinc.com
//Slave addr − also 0x29 or 0x49
//Set Command bit and address Timing Register
//Sync one 100ms integration period
//Slave addr − also 0x29 or 0x49
//Set Command bit and address Timing Register
//Integrate one SYNC IN pulse
DIGITAL COLOR LIGHT SENSORS
r
TCS3404CS, TCS3414CS
TAOS068 − FEBRUARY 2009
Copyright E 2009, TAOS Inc.
29