WM8351GEB/V Wolfson Microelectronics, WM8351GEB/V Datasheet - Page 162

no-image

WM8351GEB/V

Manufacturer Part Number
WM8351GEB/V
Description
Audio CODECs Audio CODEC plus pwr management
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8351GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WM8351
w
17.7.5
Fast charging and Trickle charging is terminated under any of the following conditions:
The End of Charge Current threshold can be set between 20mA and 90mA, using the
CHG_EOC_SEL register field, as defined in Table 106. Care should be taken to ensure that the End
of Charge Threshold is lower than the selected Charge Current Limit (CHG_ISEL and/or
CHG_TRICKLE_SEL).
When the End of Charge Current threshold is reached, the CHG_END_EINT interrupt field is set (see
Section 17.7.8). The action taken when the End of Charge Current threshold occurs is set by
CHG_END_ACT. The battery charging will either be terminated or will continue until timeout.
When Trickle charge choking or Fast charge throttling is enabled, it is possible that these circuits
may cause the charge current to be reduced below the CHG_EOC_SEL threshold even though the
battery is not fully charged. When choke or throttle control is enabled, the End of Charge detection
described above is disabled, and charging always continues until timeout. It is recommended that
Trickle charge choking and Fast charge throttling is enabled.
The WM8351 battery charger has a programmable timer. The timer is initiated when either fast
charging or trickle charging commences. The initial value of the timer may be set by writing to the
CHG_TIME register field. This field can also be read back as an indicator of the charge time
remaining. Note that the readback value of this field is coded differently to the write value. Due to the
limited resolution provided by the 4-bit field, the readback value is approximate only, to an accuracy
of around 35 minutes.
If charging is paused by setting CHG_PAUSE (see Table 103), or is paused due to temperature or
maximum current conditions, the charge timer is halted so that the time limit is extended accordingly.
If the charging mode is changed by asserting or de-asserting CHG_FAST, then the timer is reset to
its initial value.
If the charging mode reverts to Trickle charge mode as a result of a change in power source or a
change in USB power mode, then the timer is not reset, but continues to count down from its earlier
value. (Note that the charger will never autonomously switch from Trickle charge mode to Fast
charge mode.)
When the Charger Timer completes, the CHG_TO_EINT interrupt field is set (see Section 17.7.8)
and charging is terminated.
Charge current falls below a programmable threshold
Charger timeout
Charger fault condition (see Section 17.7.7)
BATTERY CHARGER TIMEOUT AND TERMINATION
PD, March 2010, Rev 4.2
Production Data
162