PKG.M0.8SL.VJ LEMO, PKG.M0.8SL.VJ Datasheet - Page 70

Circular Push Pull Connectors 8P FML RECP R/A PCB GRAY FRONT NUT

PKG.M0.8SL.VJ

Manufacturer Part Number
PKG.M0.8SL.VJ
Description
Circular Push Pull Connectors 8P FML RECP R/A PCB GRAY FRONT NUT
Manufacturer
LEMO
Series
1P Seriesr
Datasheet

Specifications of PKG.M0.8SL.VJ

Product Type
Connectors
Contact Style
Socket (Female)
Shell Style
Receptacle
Number Of Contacts
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
F v : average latching force
F d : average unmating force with axial pull on
F a : average retention force for straight pull
Contact resistance with relation to the number
of mating cyles
(measured according to IEC 60512-2 test 2a)
Average values measured after the mating cycles and the
salt spray test according to IEC 60512-6 test 11f.
Note: 1) 21 days at 95% RH according to IEC 60068-2-3.
Test voltage
Test voltage (Ue) :
(measured according to the IEC 60512-2 test 4a standard)
It corresponds to 75% of the mean breakdown voltage.
Test voltage is applied at 500 V/s and the test duration is 1 minute.
This test has been carried out with a mated plug and socket, with power supply only on the plug end.
Operating voltage (Us) :
It is proposed according to the following ratio : Us =
Caution:
For a number of applications, safety requirements for electrical appliances are more severe with
regard to operating voltage.
In such cases operating voltage is defined according to creepage distance and air clearance
between live parts.
Please consult us for the choice of a connector by indicating the safety standard to be met by the
product.
68
(mm)
A ø
0.5
0.7
0.9
1.3
1.6
2.0
F
F
F
the outer release sleeve
on the collet nut
d
a
v
Mechanical latching characteristics
resistance (mΩ)
1000 cycles
Contact
< 8.5
< 6.5
< 4.5
< 2.8
< 2.6
< 2.9
Ue
3
PSU shell material
PEI shell material
Notes: 1N = 0.102 kg.
Mechanical endurance: 1000 cycles.
Insulation resistance between the contacts
and contact/shell
(measured according to IEC 60512-2 test 3a)
Notes: The forces were measured on PSU outer shells not fitted with contacts.
The mechanical endurance represents the number of cycles after which the
latching system is still effective (1 cycle = 1 latching/unlatching – 300 cycles per
hour). The values were measured according to the standard IEC 60512-7, test
13a.
new
after humidity test
Force
Force
(N)
(N)
Fv
Fd
Fa
Fv
Fd
Fa
Insulating material
100 150 120
120 100
8.0
8.0
6.5
6.5
1P
1P
Series
Series
1)
5.5 7.5
8.5 17.0
6.0
9.0
2P
2P
3P
Multipole
> 10
> 10
PEEK
12
10
Ω
Ω

Related parts for PKG.M0.8SL.VJ