S29GL064M90TFIR40 Spansion Inc., S29GL064M90TFIR40 Datasheet - Page 71

no-image

S29GL064M90TFIR40

Manufacturer Part Number
S29GL064M90TFIR40
Description
Flash Memory IC
Manufacturer
Spansion Inc.
Series
S29GLr
Datasheet

Specifications of S29GL064M90TFIR40

Memory Size
64Mbit
Package/case
48-TSOP
Supply Voltage Max
3V
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Access Time, Tacc
90nS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S29GL064M90TFIR40
Manufacturer:
SPANSION
Quantity:
660
Command Definitions
February 7, 2007 S29GL-M_00_B8
Read (6)
Reset (7)
Enter Secured Silicon Sector Region
Exit Secured Silicon Sector Region
Program
Write to Buffer (11)
Program Buffer to Flash
Write to Buffer Abort Reset (13)
Unlock Bypass
Unlock Bypass Program (14)
Unlock Bypass Reset (15)
Chip Erase
Sector Erase
Program/Erase Suspend (16)
Program/Erase Resume (16)
CFI Query (18)
Legend:
X = Don’t care
RA = Read Address of memory location to be read.
RD = Read Data read from location RA during read operation.
PA = Program Address. Addresses latch on falling edge of WE# or
CE# pulse, whichever happens later.
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
See
All values are in hexadecimal.
Shaded cells indicate read cycles. All others are write cycles.
During unlock and command cycles, when lower address bits are
555 or 2AA as shown in table, address bits above A11 and data
bits above DQ7 are don’t care.
No unlock or command cycles required when device is in read
mode.
Reset command is required to return to read mode (or to erase-
suspend-read mode if previously in Erase Suspend) when device
is in autoselect mode, or if DQ5 goes high while device is
providing status information.
Fourth cycle of the autoselect command sequence is a read
cycle. Data bits DQ15–DQ8 are don’t care. Except for RD, PD
and WC. See
information.
Device ID must be read in three cycles.
If WP# protects highest address sector, data is 98h for factory
locked and 18h for not factory locked. If WP# protects lowest
address sector, data is 88h for factory locked and 08h for not
factor locked.
Manufacturer ID
Device ID (9)
Secured Silicon Sector Factory
Protect (10)
Sector Group Protect Verify
(12)
Table 1
Command
Sequence
(Note
for description of bus operations.
Autoselect Command Sequence
1)
Table 34. Command Definitions( x16 Mode, BYTE# = V
1
1
4
4
4
4
3
4
4
3
1
3
3
2
2
6
6
1
1
1
Addr
XXX
XXX
XXX
XXX
XXX
555
555
555
555
555
555
555
555
555
555
555
555
RA
SA
55
D a t a
First
for more
Data
S29GL-M MirrorBit
RD
AA
AA
AA
AA
AA
AA
AA
AA
29
AA
AA
A0
90
AA
AA
B0
30
98
F0
Addr
S h e e t
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
XXX
2AA
2AA
PA
Second
Data
PD
55
55
55
55
55
55
55
55
55
55
00
55
55
TM
PD = Program Data for location PA. Data latches on rising edge of
WE# or CE# pulse, whichever happens first.
SA = Sector Address of sector to be verified (in autoselect mode) or
erased. Address bits A21–A15 uniquely select any sector.
WBL = Write Buffer Location. Address must be within same write
buffer page as PA.
WC = Word Count. Number of write buffer locations to load minus 1.
10. Data is 00h for an unprotected sector group and 01h for a
11. Total number of cycles in command sequence is determined by
12. Command sequence resets device for next command after
13. Unlock Bypass command is required prior to Unlock Bypass
14. Unlock Bypass Reset command is required to return to read
15. System may read and program in non-erasing sectors, or enter
16. Erase Resume command is valid only during Erase Suspend
17. Command is valid when device is ready to read array data or
18. Refer to
Third
Addr
Flash Family
555
555
555
555
555
555
555
555
555
555
555
SA
protected sector group.
number of words written to write buffer. Maximum number of
cycles in command sequence is 21, including “Program Buffer to
Flash” command.
aborted write-to-buffer operation.
Program command.
mode when device is in unlock bypass mode.
autoselect mode, when in Erase Suspend mode. Erase Suspend
command is valid only during a sector erase operation.
mode.
when device is in autoselect mode.
per device density and model number.
Bus Cycles (Notes 2–5)
Data
90
90
90
90
88
90
A0
25
20
80
80
F0
Table
(SA)X02
17, AutoSelect Codes for individual Device IDs
Addr
XXX
X00
X01
X03
555
555
SA
PA
Fourth
(Note
00/01
0001
227E
Data
WC
00
PD
AA
AA
IH
10)
)
Addr
2AA
2AA
X0E
PA
Fifth
(Note
Data
18)
PD
55
55
Addr
WBL
X0F
555
SA
Sixth
(Note
Data
18)
PD
10
30
69

Related parts for S29GL064M90TFIR40