G6KU-2PY 3DC Omron, G6KU-2PY 3DC Datasheet - Page 3

RELAY, PCB, SPCO, 3VDC, LATCHING

G6KU-2PY 3DC

Manufacturer Part Number
G6KU-2PY 3DC
Description
RELAY, PCB, SPCO, 3VDC, LATCHING
Manufacturer
Omron
Datasheet

Specifications of G6KU-2PY 3DC

Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
3V
Coil Resistance
91ohm
Coil Power Cont
100mW
Relay
RoHS Compliant
Coil Type
DC Coil
Coil Current
33mA
Contact Configuration
DPDT
Rohs Compliant
Yes
G6K
Note:
Note:
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Contact resistance (See note 1.)
Operating (set) time (See note 2.)
Release (reset) time (See note 2.)
Insulation resistance (See note 3.) 1,000 M Ω min. (at 500 VDC)
Dielectric
strength
Impulse
withstand
voltage
Vibration resistance
Shock resistance
Endurance
Failure rate (P level) (See note 4.)
Ambient temperature
Ambient humidity
Weight
Contact Ratings
Characteristics
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
4. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω . This
the dielectric strength.
value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under
actual operating conditions.
Coil and contacts
Contacts of different
polarity
Contacts of same po-
larity
Coil and contacts
Contacts of different
polarity
Contacts of same po-
larity
Item
100 m Ω max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.3 ms)
1,500 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
1,500 V (10 x 160 µs)
1,500 V (10 x 160 µs)
Destruction: 10 to 55 Hz, 2.5-mm single amplitude (5-mm double amplitude) and 55 to 500 Hz,
300 m/s
Malfunction: 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) and 55 to 500 Hz,
200 m/s
Destruction: 1,000 ms
Malfunction: 750 ms
Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour)
10 µA at 10 mVDC
Operating: − 40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 0.7 g
Resistive load
0.3 A at 125 VAC; 1 A at 30 VDC
1 A
125 VAC, 60 VDC
1 A
G6K-2F, G6K-2G, G6K-2P
2
2
(approx. 30G)
(approx. 20G)
Single-side stable models (double-pole)
2
(approx. 75G)
2
(approx. 100G)
2,500 V (2 x 10 µs), 1,500 V (10 x 160 µs)
G6K-2F-Y, G6K-2G-Y,
G6K-2P-Y
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
G6KU-2F-Y, G6KU-2G-Y,
Single-winding latching
G6KU-2P-Y
model
G6K
93