H3DS-SL Omron, H3DS-SL Datasheet

TIMER, 4 MODE

H3DS-SL

Manufacturer Part Number
H3DS-SL
Description
TIMER, 4 MODE
Manufacturer
Omron
Datasheet

Specifications of H3DS-SL

Contact Configuration
SPDT
Nom Input Voltage
230V
Delay Time Range
0.1s To 120h
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
230V
Coil Voltage Vdc Nom
24V
Contact Current Ac Max
5A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3DS-SL AC24-230/DC24-48
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
DIN Track Mounted, Standard 17.5-mm Width Timer Range
Ordering Information
Note: The operating modes are as follows:
4
24 to 230 VAC (50/60Hz)/
24 to 48 VDC
A wide AC/DC power supply range (24 to 230 VAC/
24 to 48 VDC) reduces the number of timer models
kept in stock.
Eight operating modes (H3DS-M) and four
operating modes (H3DS-S) cover a wide range of
applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status
respectively.
Smart Dial/Selector-locking Mechanism: Prevents
the dials and selectors on the Timer’s front panel
from being inadvertently operated or being
operated without authorization. The lock can only
be unlocked and locked with an optional pen-type
Lock Key.
Screwless spring terminal type available.
Sticker provided for easy timer identification and
management.
Terminal clamp left open when delivered (screw
terminal type).
Finger
VDE0106/P100.
Enables easy sequence checks through instanta-
neous outputs for a zero set value at any time
range.
Conforms
(VDE0110) 4 kV/2.
Conforms to EMC standards (EN50081-1 and
EN50082-2).
Solid-state Multi-functional Timer
Supply voltage
Supp y o age
protection
A: ON-delay
B: Flicker OFF start
B2: Flicker ON start
C: Signal ON/OFF-delay
D: SIgnal OFF-delay
E: Interval
G: Signal ON/OFF-delay
J: One shot
to
EN61812-1
terminal
Contact output:
SPDT
(time-limit output
SPDT)
Control output
Co
)
o ou pu
and
block
IEC60664-1
to
Voltage input
No-input available
meet
Input type
pu
ype
Eight multi-modes: A,
B, B2, C, D, E, G, J
Four multi-modes: A,
B2, E, J
Single mode: A
Operating mode
Ope a
(
(see note)
g
t )
ode
H3DS-ML
H3DS-SL
H3DS-AL
terminal type
Screw
H3DS
R C
Model
H3DS-MLC
H3DS-SLC
H3DS-ALC
terminal type
Screwless
spring

Related parts for H3DS-SL

H3DS-SL Summary of contents

Page 1

... J: One shot 4 block to meet and IEC60664-1 Input type pu ype Voltage input Eight multi-modes B2 No-input available Four multi-modes Single mode: A H3DS R C Model Ope a Operating mode g ode (see note Screw Screwless terminal type terminal type H3DS-ML H3DS-MLC H3DS-SL H3DS-SLC H3DS-AL H3DS-ALC spring ...

Page 2

... Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously (l) x 7 (l) x 7 (t) H3DS-SLj A: ON-delay B2: Flicker ON start E: Interval J: One-shot --- Clamps two 2.5-mm max. bar terminals without sleeves. Time range H3DS ...

Page 3

... Reset voltage Power H3DS-MLj consumption p (see note H3DS-SLj H3DS-ALj Voltage input Control output Ambient temperature Ambient humidity Note ripple rate: 20% max. 2. Since an inrush current of 0.4 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off the power supply to the Timer with a solid-state output such as a sensor ...

Page 4

... ENV50204: Immunity Conducted Disturbance: ENV50141: Immunity Burst: EN61000-4-4:2 kV power line (level 3) Light gray (5Y7/1) IP30 (Terminal block: IP20) 100 g H3DS 8 kV air discharge (level 3) 10 V/m (80 MHz to 1 GHz) (level 3) 10 V/m (900 5 MHz) (level (0. MHz) (level I/O signal line (level 4) 7 ...

Page 5

... Operating mode display window and selector (select the mode from and J for the H3DS-ML, from A, B2, E, and J for the H3DS-SL) H3DS-ALj Output indicator (orange) (Lit while Timer output is ON.) Set time window Time scale display window and selector (select one from ...

Page 6

... J. Turn the operating mode selector with a screwdriver until the desired operating mode appears in the operating mode display win- dow. H3DS-ML (8 modes B2 (In order of appearance) H3DS-SL (4 modes B2 (In order of appearance) Note: Letters that appear more than once indicate exactly the same operating mode. Selection of Time Scale The time scale is selected by turning the time scale selector ...

Page 7

... Output relay and 16 Output relay: NO (output indicator) 15 and 18 Power indicator Note: The start input of the H3DS-MLj model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to T erminal Arrangement ). 10 Timing chart t t– t– ...

Page 8

... Output relay 0.6 s (output indicator) (fixed) 15 and 18 Power indicator Note: The start input of the H3DS-MLj model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to T erminal Arrangement ). Timing chart t–a t–a t t–a ...

Page 9

... A2 (see note 1) Note supply voltage does not require the designation of polarity. 2. The contact symbol for the H3DS is indicated with contact for conventional timers. 12 Surface color: Light gray 5Y7/1 (OMRON) H3DS-SLj/-ALj (see note 1) because it offers multiple operating modes and is different from the delayed ...

Page 10

... H3DS Input Connections The inputs of the H3DS-MLj are voltage (voltage imposition or open) inputs. No-contact Input (Connection to PNP output sensor.) Sensor Timer (+) Start 24 VDC (– Operates with PNP transistor ON Voltage Input Signal Levels 1. Transistor ON Residual voltage max. (Voltage between terminals B No-contact input the rated “ ...

Page 11

... Note: The values shown in parentheses are for the PFP-50N. End Plate PFP pan head screw 14 PFP-100N2 7.3 0.15 4.5 27 0. (5) (see note) Spacer PFP-S 10 6.2 1.8 1 35.5 35.3 1.8 1.3 4.8 H3DS 0 1,000 34.8 44.3 16.5 29.2 1.5 ...

Page 12

... Timer. Both AC and DC power supplies can be connected to the power in- put terminals without regarding polarity. With the H3DS only power supply must be connected to the power input terminals as designated according to the polarity of the terminals power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer ...

Page 13

... The H3DS as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied: The output section of the H3DS is provided only with basic isolation. To ensure reinforced isolation required by the EN61812-1, provide supplementary basic isolation on the load side connected to the out- put ...