ZBZ1604 SQUARE D, ZBZ1604 Datasheet - Page 166

Switch Guard

ZBZ1604

Manufacturer Part Number
ZBZ1604
Description
Switch Guard
Manufacturer
SQUARE D
Datasheet

Specifications of ZBZ1604

Features
Red, Metal
For Use With
40mm Emergency Stop And Mushroom Head Pushbuttons
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Push Button and Operator Interface - Type KX 30 mm
Selector Switch Selection Guide
Shown below is a simplified method of selecting a selector
switch to meet almost any combination of contact sequences.
Step No. 1
Determine the contact sequence(s) required. Set up a target ta-
ble like the one shown for the example below.
Example:
Step No. 2
Look for a cam type common to all sequences in Table 1, 2 or
3. For the example above, Table 2 would be used. For the con-
tact sequences A(1 0 0), B(0 1 0) and C(0 0 1) of the example
above, cam types F and L are common to all 3 sequences.
Step No. 3
Next, the cam type common to all the sequences (If several
cam types are common, choose one.) is used to find the oper-
ator type number. Go to the proper page number as indicated
in the table below:
If for the example above:
A manual return operator with a standard black knob is required and
Step No. 4:
Determine the contact blocks required by using the same table
used for Step No. 2.
If for the example above:
The F cam type were chosen:
The L cam type were chosen:
One Type KA1 double circuit block can be used in place of one
Type KA2 single circuit block and one Type KA3 single circuit
block mounted on the same side.
“H” Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 174
Outline Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 176
166
Number of Positions
If the F cam type were chosen, the operator type number would be:
If the L cam type were chosen, the operator type number would be:
A 9001KA3 mounted on side no. 2 would be used for sequence A(1 0 0).
A 9001KA3 mounted on side no. 1 would be used for sequence B(0 1 0).
A 9001KA2 mounted on side no. 1 or 2 would be used for sequence
C(0 0 1).
A 9001KA2 mounted on side no. 2 would be used for sequence A(1 0 0).
A 9001KA2 mounted on side no. 1 or a 9001 KA3 mounted on side no.
2 would be used for sequence B(0 1 0).
A 9001KA3 mounted on side no. 1 would be used for sequence C(0 0 1).
Sequence
© 1999-2005 Schneider Electric All Rights Reserved
Contact
A
B
C
Type KX Line – Class 9001 Type KXSDFB (from page 167)
Type KX Line – Class 9001 Type KXSDLB (from page 167)
2
3
4
KA1
1
0
0
Push Button Line
1 – contact closed
0 – contact open
=
=
Type KX
Type KX
Type KX
KA3
+
+
KA2
0
1
0
Page Number
167
167
167
0
0
1
Table 1 – 2 Position Selector Switch
Table 2 – 3 Position Selector Switch
Table 3 – 4 Position Selector Switch
1
0
0
0
1
1
0
0
1
0
1
0
1
1
contact sequence
1
0
0
1
0
1
The KA5 must be the last block on either side. If more than one KA5 is required on either
side – contact your local Square D sales office.
If you require
contact sequence
contact sequence
1
0
If you require
If you require
0
1
0
0
0
1
1
0
1
1
0
1
1
0
0
1
0
1
1
0
0
0
1
0
0
0
1
1
1
1
1
0
0
1
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
0
1
1
with cam type
Use Sel. Sw.
B C
B
B
B
B
B
with cam type
C
C
C
Use Sel. Sw.
H
H
H
H
H
H
H
H
H
H
H
H
H
H
with cam type
D E
D E
D
D
D E
D E
Use Sel. Sw.
E
D
E
D
E
E F G J
F
F
F
G
G J
G
G J
G
J L
J
J L
L
L
L
L
Use contact
block type
(A) KA3
(B) KA2
(C) KA2
(D) KA3
Use contact
M
M
M
M
KA5 ✻
KA5 ✻
block type
A, B & C Wired in Parallel
B, C & D Wired in Parallel
Use contact
C & D Wired in Parallel
block type
A & D Wired in Parallel
A & B Wired in Parallel
B & C Wired in Parallel
A & C Wired in Parallel
B & D Wired in Parallel
KA3
KA2
KA2
KA3
KA5 ✻
KA5 ✻
KA5 ✻
KA5 ✻
KA5 ✻
KA5 ✻
KA5 ✻
KA2
KA2
KA3
KA3
KA2
KA2
KA3
KA3
KA2
KA3
KA3
KA2
KA2
KA3
KA2
KA3
KA3
(See page 174)
(See page 174)
(See page 174)
Mount on
side No.
Mount on
Mount on
side No.
side No.
1 or 2
1 or 2
1 or 2
1 or 2
1 or 2
1 or 2
2
1
2
1
2
1
1
2
1
2
2
1
2
1
2
1
1
2
1
2
2
1
2
1
1
1
2
2
04/2005