ZBZ1604 SQUARE D, ZBZ1604 Datasheet - Page 192

Switch Guard

ZBZ1604

Manufacturer Part Number
ZBZ1604
Description
Switch Guard
Manufacturer
SQUARE D
Datasheet

Specifications of ZBZ1604

Features
Red, Metal
For Use With
40mm Emergency Stop And Mushroom Head Pushbuttons
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
192
Push Button and Operator Interface - Type B and 30 mm Control Stations
Types K, SK, KX, and T — 30 mm Reed Contact Blocks & Hazardous Location Information
In hazardous locations, it is not always required to use explosion-proof
equipment like the Class 9001 Type BR control stations. Knowing what
type of hazardous location exists will permit you to select the most eco-
nomical solution to your application. If you're not sure what type of haz-
ardous location exists, the “Summary of Classification” chart may help.
If not, contact your local electrical inspector. When you know what
class, division, and group(s) exists, see the table in the lower lefthand
corner of this page for what Square D has to offer.
Summary Of Classification Chart
For ◆: Add Form Y243 to single lamp Push To Test pilot lights.
I. Gas
II. Dust
III. Fibers
Class
An intrinsically safe system requires either a Class 8501 Type TO or NY2 barrier relay or an
intrinsically safe barrier to restrict the energy available in the area classified as a hazardous
area to a level less than that required to cause an explosion. In an intrinsically safe system,
any non-illuminated Class 9001 operator or control station with standard contacts can be
used. No illuminated operators, except the Class 9001 Type KP44 intrinsically safe pilot light,
may be used.
Any Class 9001 Type K, SK or KX operator can be used in an area classified as Class I, Divi-
sion 2 hazardous locations.
1. Only logic (KA40 series) or power (KA50 series) reed contact blocks are used.
2. All Type K and SK illuminated operators are UL approved for use in Class I Division 2
3. Type KX illuminated operators do not use 4 lamp light modules, or 2 lamp light modules
4. The operators are mounted in Type KY, KYSS, KYAF, SKY enclosures.
Any Class 9001 Type K, SK, or KX operator mounted in a Class 9001 Type KY, KYSS, KYAF,
SKY enclosure may be used, except potentiometer operators.
III
II
II
II
I
I
I
I
© 1999-2005 Schneider Electric All Rights Reserved
areas. ◆
other than the transformer type. ◆
Class
Division
1, 2
1
1
2
2
1
2
2
For
1. Hazard May Exist
2. Potential Hazard
1. Hazard May Exist
2. Potential Hazard
1. Production Areas
2. Handling and Storage
Group(s)
B, C, D
B, C, D
E, F, G
E, F
May Exist In Atmosphere
Under Normal Operating
Conditions.
A. May be present in
B. Location adjacent to
May Exist In Atmosphere
Under Normal Operating
Conditions.
A. May be present in
Areas
G
A
A
atmosphere only
under abnormal
circumstances.
Division 1 location.
atmosphere only
under abnormal
circumstances.
Division
1. Intrinsically Safe System
1.
2.
1.
2.
1.
2.
3.
1.
2.
1.
2.
3.
1.
2.
3.
1.
2.
3.
9001 BR station
Intrinsically Safe System
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR Station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
G. Non-Conductive Combustible Dust
G. Non-Conductive Combustible Dust
A. Acetylene
B. Hydrogen and Manufactured Gases
C. Petrochemicals (e.g. ethylene)
D. Petrochemicals (e.g. alcohol)
A. Acetylene
B. Hydrogen and Manufactured Gases
C. Petrochemicals (e.g. ethylene)
D. Petrochemicals (e.g. alcohol)
E. Conductive and Combustible Dust
F. Carbonaceous Dusts (Resistivity
containing Hydrogen
Containing Hydrogen
(Resistivity <10
>10
(Resistivity > = 10
(Resistivity > = 10
Easily Ignitable Fibers or Flyings
Easily Ignitable Fibers or Flyings
2
Use
ohm/cm but ð 10
Group
5
ohms/cm)
5
5
ohms/cm)
ohms/cm)
8
ohm/cm)
All contact blocks listed below will accept #12-18 solid or stranded wire.
Hermetically Sealed Logic Reed Contact Blocks
Suitable for use on low energy level circuits
The maximum number of logic and/or power reed contact blocks per operator
is the same for standard contact blocks,
except:
• On 3 position selector switches with cams “C,” “D,” “E,” “F,” “G,” “L,” or “M”
• On 4 position selector switches, mount reed blocks on one side only (ei-
Hermetically Sealed Power Reed Contact Blocks
The power reed contact blocks can be used with standard industrial relays and starters through
Pilot Light For Intrinsically Safe Circuits — NEMA / UL Type 4X
NEMA Size 4. Minimum voltage is 5 volts and the minimum current is 1 mA.
Inductive Rating – 35% Power Factor.
Inductive and Resistive Ratings.
On joysticks or on Type KR8 or SKR8 push-pull operators, mount reed blocks
mount reed blocks on one side only (either side), maximum 2 in tandem.
ther side), maximum 2 in tandem.
on one side only (either side), maximum 2 in tandem
Volts
Volts
120
240
115
I max. = 165 mA
V max. = 32 V
Description
Description
Max. Volts AC/DC
120/100
Amps
Amps
32/30
10.00
0.50
5.00
Make
Make
ergy capable of igniting certain explosive or combustible hazardous at-
mosphere, for which the equipment has been tested.
a suitable approved barrier or barrier relay (Class 8501 Type TO or
NY2. These pilot lights are Factory Mutual FM# J.I. OH4A2,AX,3610
(FM approved). Consult your local Square D Sales Office for further de-
tails.
parts – except for the SK40 ring nut. Use KN100 series plastic legend
plates.
Intrinsically safe equipment must not release electrical or thermal en-
Listed below are pilot lights that are intrinsically safe when used with
These pilot lights are fully encapsulated – there are no replaceable
Operating
Voltage
20-30 V
Range
AC/DC
1200
1200
VA
VA
58
AC NEMA / UL Type C300
DC NEMA / UL Type Q150
Symbol
Symbol
Nominal
Current
0.25 A
Amps
Amps
Res.
1.000
0.500
25 mA
8 VA
0.50
Break
Break
Maximum Load
0.10 A
.
Green
Yellow
Color
3 VA
Ind.
Lens
120
120
Red
VA
VA
58
KA41
KA42
KA43
KA44
KA45
KA51
KA52
KA53
KA54
KA55
Type
Type
Continuous
Continuous
Carrying
Carrying
KP44G
Amps
Amps
KP44R
KP44Y
Cont.
04/2005
0.5 A
0.5 A
Type
3.0
3.0
3.0

Related parts for ZBZ1604