TLE4990 Infineon Technologies, TLE4990 Datasheet - Page 19

IC HALL EFFECT UNI/BIPOL PGSSO41

TLE4990

Manufacturer Part Number
TLE4990
Description
IC HALL EFFECT UNI/BIPOL PGSSO41
Manufacturer
Infineon Technologies
Type
Linear - Programmabler
Datasheet

Specifications of TLE4990

Sensing Range
32mT ~ 75mT
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
5.5mA
Current - Output (max)
1.2mA
Output Type
Analog, Ratiometric
Operating Temperature
-40°C ~ 150°C
Package / Case
4-SIP, SSO-4-01
Operating Supply Voltage
5 V
Mounting Style
Through Hole
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Maximum Output Current
1.2 mA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
TLE4990INTB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE4990
Manufacturer:
INFINEON
Quantity:
20 000
Part Number:
TLE4990
Manufacturer:
原装INFIN
Quantity:
20 000
Company:
Part Number:
TLE4990-E6782
Quantity:
7 338
TLE4990
Programmable Linear Hall Sensor
Calibration and Fusing
8
Calibration and Fusing
Usually the sensor is calibrated ’End Of Line’, when the complete magnetic system is
assembled. This compensates all magnetic and mechanical tolerances.
Note: The -E6782 version is already programmed completely. The contents of the
calibration OTP memory may not be changed furthermore.
During the calibration the internal settings are stored in a RAM. When the right values
are found, the information has to be stored in an one-time-programmable memory
(OTP).
This OTP memory consists of cavity fuses.
After fusing all bits, setting the MEMLOCK bit closes the memory. This prevents from
unwanted memory changes after the calibration
Data Transfer Protocol
A separate programming specification may be requested.
Programming of Sensors with Common Supply Lines
In many automotive applications two sensors are used to measure the same parameter.
This redundancy allows to continue the operation in an emergency mode. If both sensors
use the same power supply lines, they have to be programmed together.
Sensor Interface Tool
For the calibration of the sensor, a special hardware interface to a PC is required.
Data Sheet
19
V 2.4, 2005-11