AS5046-ASST austriamicrosystems, AS5046-ASST Datasheet - Page 18

IC ENCODER PROG 12-BIT 16-SSOP

AS5046-ASST

Manufacturer Part Number
AS5046-ASST
Description
IC ENCODER PROG 12-BIT 16-SSOP
Manufacturer
austriamicrosystems
Type
Linear, Rotary Encoder - Programmabler
Datasheet

Specifications of AS5046-ASST

Sensing Range
45mT ~ 75mT
Voltage - Supply
3 V ~ 3.6 V, 4.5 V ~ 5.5 V
Current - Supply
21mA
Current - Output (max)
4mA
Output Type
Analog, Ratiometric
Features
Programmable
Operating Temperature
-40°C ~ 125°C
Package / Case
16-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
AS5046-ASSTTR
AS5046
Data Sheet
For each Hall Sensor, the corresponding Front End contains 8 bits
TestEN:
SenseEN:
COS_EN:
SIN_EN:
INV:
PD:
Note: When enabling or disabling individual Hall elements to the SIN- and COS- signal buses it is recommended to allow
several milliseconds (typ. 5ms) of dwelling time until the signal is stable and eventual offsets are compensated.
11.3 Hall Sensor Front-End Configuration
The default configuration for the Hall Sensor Front-End is set for angle measurement. This configuration must always
be programmed when an angle should be measured and read from the Serial Interface Unit register.
Table 16 Hall Sensor Front-End Default Configuration
The following configuration example selects Hall Sensor 0 and assigns it to the SIN signal bus:
Table 17 Example: Readout of a Single Hall Sensor (Sensor #0)
This example uses two opposite Hall sensors 1 and 5 in differential mode and assigns the resulting signal to the COS
signal bus:
www.austriamicrosystems.com
FE0
FE1
FE2
FE3
FE4
FE5
FE6
FE7
FE0
FE1
FE2
FE3
FE4
FE5
FE6
FE7
Addr. 000…111
Type ID: 0001
Addr
000
001
010
011
100
101
110
111
Addr
000
001
010
011
100
101
110
111
always set to 0
set to 1 for enabled Hall Elements, set to 0 for disabled Hall Elements
set to 0 for disabled Hall Elements, set to 1 if this Hall Element should be added to the COS signal
bus. It is also possible to enable multiple Hall sensors to this bus
set to 0 for disabled Hall Elements, set to 1 if this Hall Element should be added to the SIN signal
bus. It is also possible to enable multiple Hall sensors to this bus
set to 1 if the Hall Element should be inverted for differential measurement. Set to 0 if the Hall
Element should not be inverted
set to 0 for normal operation, set to 1 if the Hall Sensor should be powered down.
testEN
0
0
0
0
0
0
0
0
testEN
0
0
0
0
0
0
0
0
TestEN
SenseEN
1
1
1
1
1
1
1
1
SenseEN
1
0
0
0
0
0
0
0
SenseEN
NC
0
0
0
0
0
0
0
0
NC
0
0
0
0
0
0
0
0
NC
0
0
0
0
0
0
0
0
NC
0
0
0
0
0
0
0
0
NC
Revision 1.12
COS_EN
0
0
1
1
0
0
1
1
COS_EN
0
0
0
0
0
0
0
0
NC
Byte1
COS_EN
SIN_EN
1
1
0
0
1
1
0
0
SIN_EN
1
0
0
0
0
0
0
0
SIN_EN
Inv
0
0
0
0
1
1
1
1
Inv
0
0
0
0
0
0
0
0
PD
0
0
0
0
0
0
0
0
PD
0
0
0
0
0
0
0
0
INV
PD
18 – 42