AS5163-HTST-500 austriamicrosystems, AS5163-HTST-500 Datasheet - Page 16

IC ENCODER ROTARY 14-TSSOP

AS5163-HTST-500

Manufacturer Part Number
AS5163-HTST-500
Description
IC ENCODER ROTARY 14-TSSOP
Manufacturer
austriamicrosystems
Type
Linear, Rotary Encoder - Programmabler
Datasheet

Specifications of AS5163-HTST-500

Featured Product
AS5163 - Contactless Magnetic Angle Position Sensor
Sensing Range
30mT ~ 70mT
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
20mA
Output Type
Analog, Ratiometric
Operating Temperature
-40°C ~ 150°C
Package / Case
14-TSSOP (0.173", 4.40mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output (max)
-
Features
-
Other names
AS5163-HTST-500TR
AS5163
Datasheet - A p p l i c a t i o n I n f o r m a t i o n
8 Application Information
The benefits of AS5163 are as follows:
8.1 Programming the AS5163
The AS5163 programming is a one-time-programming (OTP) method, based on polysilicon fuses. The advantage of this method is that no
additional programming voltage is needed. The internal LDO provides the current for programming.
The OTP consists of 128 bits, wherein several bits are available for user programming. In addition, factory settings are stored in the OTP
memory. Both regions are independently lockable by built-in lock bits.
A single OTP cell can be programmed only once. By default, each cell is “0”; a programmed cell will contain a “1”. While it is not possible to reset
a programmed bit from “1” to “0”, multiple OTP writes are possible, as long as only unprogrammed “0”-bits are programmed to “1”.
Independent of the OTP programming, it is possible to overwrite the OTP register temporarily with an OTP write command. This is possible only
if the user lock bit is not programmed.
Due to the programming over the output pin, the device will initially start in the communication mode. In this mode, the digital angle value can be
read with a specific protocol format. It is a bidirectional communication possible. Parameters can be written into the device. A programming of the
device is triggered by a specific command. With another command (pass2funcion), the device can be switched into operation mode (analog or
PWM output). In case of a programmed user lock bit, the AS5163 automatically starts up in the functional operation mode. No communication of
the specific protocol is possible after this.
8.1.1 Hardware Setup
The pin OUT and the supply connection are required for OTP memory access. Without the programmed Mem_Lock_USER OTP bit, the device
will start up in the communication mode and will remain into an IDLE operation mode. The pull up resistor R
startup.
Figure 11. Programming Schematic of the AS5163
www.austriamicrosystems.com/AS5163
Unique fully differential patented solution
Best protection for automotive applications
Easy to program
Flexible interface selection PWM, analog output
Ideal for applications in harsh environments due to contactless position sensing
Robust system, tolerant to magnet misalignment, airgap variations, temperature variations and external magnetic fields
No calibration required because of inherent accuracy
High driving capability of analog output (including diagnostics)
Figure 1
shows the configuration of an AS5163.
(low ESR)
2.2µF
SENSOR PCB
1µF
(low ESR)
0.3 ohm
2.2µF
GNDA
VDD5
VDD3
AS5163
GNDD GNDP
VDD
KDOWN
OUT
VDD
GND
Revision 2.7
DIO
GND
VDD
R
Communication
Communication
Programmer
is required during
16 - 36