V600-HAR81 Omron, V600-HAR81 Datasheet

RFID Flag Amplifier

V600-HAR81

Manufacturer Part Number
V600-HAR81
Description
RFID Flag Amplifier
Manufacturer
Omron
Datasheet

Specifications of V600-HAR81

For Use With
V600 RFID
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
• Equipped with a wiring reduction mode and communications
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
■ Amplifier
2
Power supply
Current consumption 130 mA max.
Input
Output
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case
Dielectric strength
100 mm max.).
tions from Kanban to quality control.
parity check function (16-bit models).
Intelligent Flag I/II
V600-HA
Item
Intelligent Flag I/II
Model
Type
24 VDC ±10%, ripple (p-p): 10%
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
ON voltage:
Input impedance:
Applied voltage:
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
V600-HAR91
Read-only (8-bit)
V600-HA
PNP open collector
output, 20 mA max.
at 30 VDC, residual
voltage: 2 V max.
15 to 30 VDC
0 to 5 VDC
8.2 kΩ
30 VDC max.
V600-HAR81
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
V600-HAM91
Multi-functional (8-bit)
PNP open collector out-
put, 20 mA max. at 30
VDC, residual voltage: 2 V
max.
V600-HAM81
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 kΩ
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
NPN open collector output, 20 mA
max. at 30 VDC, residual voltage: 2 V
max.
Read-only (16-bit)
V600-HAR92

Related parts for V600-HAR81

V600-HAR81 Summary of contents

Page 1

... Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current max.) V600-HA 2 Intelligent Flag I/II Multi-functional (8-bit) V600-HAR81 V600-HAM91 VDC VDC 8.2 kΩ 30 VDC max. PNP open collector ...

Page 2

... Note: The interface cable connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it inside the control box. The maximum cable length Multi-functional (8-bit) V600-HAR81 V600-HAM91 times each in 6 directions Write Writes on the set address the 8-bit (1 byte) data designated via the 8 data input lines ...

Page 3

... V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous) • V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface 5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces. 6. The Data Carrier is stationary. V600-HA ...

Page 4

... Amplifier (Cable length: fixed to 0.5 m, with connector) interface Interface cable available in three lengths and 10 m (10 m max.) Host Programmable Controller, I/O terminal, B7A, CompoBus/S, etc. Terminal block wiring Interface cable V600-A6 R Connector pins: 20 Cable lengths Connector Connector connection connection Amplifier Power ...

Page 5

... Characteristic Data (Typical) ■ Transmission Range Combinations with the V600-HS51 Sensor V600-HS51 & V600-D23P53 –8 – V600-HS51 & V600-D23P61 –15 –10 – Combinations with the V600-HS61 Sensor V600-HS61 & V600-D23P53 –8 – V600-HS61 & V600-D23P61 –25 –20 –15 –10 – V600-HA ...

Page 6

... Combinations with the V600-HS63 Sensor V600-HS63 & V600-D23P55 –30 –20 – V600-HS63 & V600-D23P66SP –50 –40 –30 –20 – V600-HS63 & V600-D8KR12 –60 –40 – V600-HS63 & V600-D23P61 –40 –30 –20 – V600-HS63 & V600-D23P71 –60 –40 – V600-HS63 & V600-D8KR04 ...

Page 7

... The transmission time refers to the time required for communications between the Sensor and the Data Carrier used for calculating the travel speed of the auto command. DC speed Distance travelled in the transmission range = (conveyor Transmission time speed) Model Mode type Data Carrier type EEPROM 75 ms SRAM 60 ms Example: Combinations with the V600-HAR91, V600-HS63, and V600-D8KR04 Sensors –80 –60 –40 – ...

Page 8

... ON and to “0" when it turns OFF. Do not use a solid-state output with the following ratings with the V600-HAM91/-HAM81, otherwise an external input error may result. 1. Maximum switching current min. 2. Minimum switching current min. 3. Response time (ON to OFF min. V600-HAR81 V600-HAM81 Input Circuit + Main circuit 8.2 k Ω ...

Page 9

... Compatibility with the SRAM Memory Type Data Carrier 1. If the Data Carrier is stationary in the transmission area for a long time when using the V600-HA@91/81 in the AUTO mode, or when using the V600-HAR92, it will drastically reduce the battery life. Therefore, stop the oscillation in the sensor either by turning off the power of the V600-HA@91/81/92 Amplifier or by setting the Inhibit input to ON ...

Page 10

... Enlarged Section of Mounting Hole 4.4 30 5.5 30 30û 21 17.5 28.3 36.3 61.8 68.5 80 Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.5 m XG4E-2031 25 Mounting Hole Dimensions 55 6 2-M4 35.2 21±0.2 500 mm 28.1 44.7 25 V600-HA Intelligent Flag I/II 89±0.2 11 ...

Page 11

... V600-HAM91/-HAM81 30 Two mounting 21 holes * 89 98 8.2 V600-HA 12 Intelligent Flag I/II * Enlarged Section of Mounting Hole 4.4 30 5.5 30˚ 17.5 28.3 36.3 44.3 52.3 61.8 68 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m XG4E-2631 25 Mounting Hole Dimensions 55 6 2-M4 89±0.2 35.2 21± ...

Page 12

... Vinyl-insulated round cord (4-mm dia.) (mounting holes) 6.5 25 Mounting Hole Dimensions 55 6 2-M4 89±0.2 35.2 21±0.2 500 mm 28.1 52.3 25 Case: Brass Transmission window: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) V600-HA Intelligent Flag I/II 13 ...

Page 13

... V600-HS63 5 Power indicator (green) V600-HS67 Power indicator (green) 14 Interface Cable V600-A6@R (for V600-HAR91/-HAR81)) V600-HA 14 Intelligent Flag I/II Two, 4.5-dia. mounting holes 2-R5 4-R1 Bushing Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) 100 ± 0 100 90 ± 0 +100 330 ±5 20 ± ...

Page 14

... V600-A6@M (for V600-HAM91/-HAM81/-HAR92) Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 +5 +100 330 ±5 20 ±5 20 ±5 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length Intelligent Flag I/II 10.6 30 7.6 30 ±5 37.6 XG5M-2632-N Connector V600-HA 15 ...

Page 15

... For US technical support or other inquiries: 800-556-6766 Cat. No. GC RFID 4 5/03 V600-HA 16 Intelligent Flag I/II of all possible uses of this product, nor is it intended to imply that the uses listed may be suitable for this product: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog ...

Related keywords