V600-D23P66N Omron, V600-D23P66N Datasheet

RFID Modules & Development Tools 256 BYTE RFID TAG

V600-D23P66N

Manufacturer Part Number
V600-D23P66N
Description
RFID Modules & Development Tools 256 BYTE RFID TAG
Manufacturer
Omron
Datasheet

Specifications of V600-D23P66N

Frequency Range
530kHz
Memory Size
256Byte
Width
34mm
Tag Memory
EEPROM
Read/write Cycles
100000
Diameter
8mm
Height
3.5mm
Tag Technology
Passive
Depth
34mm
For Use With
V600 RFID
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Non-contact Data Communications System
• Superior environmental resistance.
• Heat-resistant type available (150°C max.).
• High memory capacity of 8 Kbytes for Built-in-battery Data
• Built-in-battery Data Carriers have a battery life detecting
• Data of Battery-less Data Carriers can be overwritten
• Thin, compact, and low-cost Data Carriers are available.
• Transmission distance of 100 mm max.
Ordering Information
■ Data Carriers
2
Built-in-battery DCs
Replaceable-battery DCs Compact
Battery-less DCs
Carriers and 254 bytes for Battery-less Data Carriers.
function.
300,000 times at normal temperatures.
Electromagnetic Coupling RFID System
V600
Item
Electromagnetic Coupling RFID System
Rectangular compact
65 × 40 × 15 mm
Thin rectangular
86 × 54 × 10.3 mm
Intermediate-range rectangular
86 × 54 × 20 mm
65 × 40 × 5 mm
Ultrathin card-type
86 × 54 × 1.5 mm
Thin half-size card-type
50 × 34 × 1.5 mm
Rectangular
34 × 34 × 3.5 mm
Rectangular package with PFA
95 × 36.5 × 6.5 mm
Rectangular compact
32 × 24 × 6 mm
Round super-compact
8 dia. × 5 mm
Round compact
12 dia. × 6 mm
Round super-compact
8 dia. × 5 mm
Specifications/Design/Memory capacity
8 Kbytes
2 Kbytes
254 bytes
V600
Model
V600-D8KR12
V600-D8KR13
V600-D8KR04
V600-D2KR16
V600-D23P71
V600-D23P72
V600-D23P66N
V600-D23P66SP
V600-D23P61
V600-D23P53
V600-D23P54
V600-D23P55

Related parts for V600-D23P66N

V600-D23P66N Summary of contents

Page 1

... Rectangular compact 32 × 24 × Round super-compact 8 dia. × Round compact 12 dia. × Round super-compact 8 dia. × Electromagnetic Coupling RFID System 8 Kbytes 2 Kbytes 254 bytes V600 Model V600-D8KR12 V600-D8KR13 V600-D8KR04 V600-D2KR16 V600-D23P71 V600-D23P72 V600-D23P66N V600-D23P66SP V600-D23P61 V600-D23P53 V600-D23P54 V600-D23P55 ...

Page 2

... Carrying Belt are included. AC Power Supply 100 to 240 VAC, 50/60 Hz Relay contact output type 150 to 240 VAC, 50/60 Hz Transistor output type Handheld Reader/Writer RS-232C Host Interface; use V600-A20 power pack. Specifications/Design 0.5-m cable 2-m cable 5-m cable 10-m cable 0.5-m cable ...

Page 3

... For the V600-D2KR16 *Mount with M3 flat countersunk head screws (at least two). For the V600-D23P71/D23P72 Ultrasonic deposition can be used on the plastic container. Attachment For the V600-D23P66N Lithium battery For the V600-D2KR16 Commercially available CR2016 battery (includes replacement battery cover seal, and cover) ...

Page 4

... Approx 6.5 g Approx Approx. 5.8 g Approx. 0.4 Electromagnetic Coupling RFID System Round Round Round Compact Super- Compact Super- compact compact V600- V600- V600- V600- D23P61 D23P53 D23P54 D23P55 10 years (−40 to 110°C) 1 year (−40 to 150°C) −40 to 150°C (See note.) −25 to 85°C − ...

Page 5

... Rectangular Intermediate Range V600-D8KR13 V600-D8KR04 2 acceleration for 11 min each in X, Approx. 160 g V600 Rectangular Compact with Replaceable Battery V600-D2KR16 2 Kbytes 2 years (at 25°C) (See note 2.) Unlimited (Does not affect battery life) −15 to 70° 50°C −15 to 70°C 35% to 85% IEC 60529: IP50 (dustproof) (See note 3 ...

Page 6

... Indicators Power: green; transmission: orange Weight Approx (with 10-m cable) Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52. 2. The connectors are not water-resistant. V600-H11/H11-R 2 acceleration with 3 sweeps of 11 min each and Z directions ...

Page 7

... CRC in both directions (CRC: Cyclic Redundancy Check) detection Indicators --- Weight Approx (with 2-m cable) Note: 1. Extension cables are also available. The maximum cable length for the V600-HA51. Extension cables are not available for the V600-HS51/HS61. 2. The connectors are not water-resistant. 8 Electromagnetic Coupling RFID System Sensor section ...

Page 8

... IEC 60529: IP30 (panel mounted) Weight Approx. 890 g ■ Monitor Unit V600-P01 (for use with V600-CA@A Controllers) The Monitor Unit is a monitoring device that can be mounted Controller. It can be used to test communications between the R/W Head and Data Carrier when the RFID System is started up, check the data in Data Carriers, and read error information or statistical error information ...

Page 9

... Item Description Handheld ID Controller Controller Battery Charger Accessory Battery Case Accessory (for alkaline batteries) Ni-Cd Battery Pack Accessory (built- Controller) V600-A12 Carrying Belt Accessory Handheld V600-CH1D Wand Power supply Permissible power supply voltage Current consumption Insulation resistance Dielectric strength Noise immunity ...

Page 10

... Checks for CPU errors, memory errors, power interruptions, and transmission errors Ground to 100 Ω or less. Ground Construction Installed in panel Weight Approx. 1,500 g Note: Refer to the applicable ID Controller Operation Manual (Cat. No. W250) for details. IDSC Series IDSC-C1DR-A IDSC-C1DT times each and Z directions Electromagnetic Coupling RFID System 2 acceleration for 80 min each and Z V600 11 ...

Page 11

... R/W Head Data Carrier Iron Non-metallic (Resin, plastic, wood, etc.) Data transmission will be impossi- ble if the DC is installed directly on a metal surface. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. ...

Page 12

... Recommended combinations Data Carrier R/W Head V600-D23P66N V600-H07 Stationary Read Moving V600-H11/-H11-R Stationary Read Moving V600- V600-H07 Stationary Read D23P66SP Moving V600-H11/-H11-R Stationary Read Moving Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit ...

Page 13

... Data Carrier V600-H5 R/W Head Iron Iron (SC, SS) R/W Head Data Carrier Iron Iron (SC, SS) The listed transmission distances also apply for installation on non- metallic surfaces. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. ...

Page 14

... Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. Installation Controller ...

Page 15

... Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. 16 Electromagnetic Coupling RFID System ...

Page 16

... All metal Data Carrier Surface-mounted on metal All metal Data Carrier Flush-mounted in metal All metal The listed transmission distances also apply for installation on non- metallic surfaces. Refer to the V600 R/W Heads and SRAM Data Carri- ers Operation Manual (Cat. No. Z127) for details. V600 17 ...

Page 17

... V600 Condition for DC and R/W head distance installation The listed transmission distances also apply for installation on non- metallic surfaces. Refer to the V600 R/W Heads and SRAM Data Carri- ers Operation Manual (Cat. No. Z127) for details min min. Flush-mounted All metal (Axial offset: ± ...

Page 18

... Read range (in transmission distance priority mode) V600-D23P71 & V600-H11 X –100 –80 –60 X V600-D23P72 & V600-H11 X –80 –60 X V600-D23P66N & V600-H11 X – 80 – 60 100 X V600-D23P66SP & V600-H11 X 100 – 80 – V600-D23P61 & V600-H51 X 50 – 40 – Write range (in transmission distance or transmission time priority mode) ...

Page 19

... V600-D23P53 & V600-HS51 +V600-HA51 – 10 – V600-D23P54 & V600-HS51 +V600-HA51 – 15 – 10 – V600-D23P55 & V600-HS51 +V600-HA51 – 15 – 10 – Read range (in transmission distance priority mode) 20 Electromagnetic Coupling RFID System V600-D23P53 & V600-HS61 +V600-HA51 – 10 – V600-D23P54 & V600-HS61 +V600-HA51 – 15 – ...

Page 20

... Replaceable-Battery DCs V600-D2KR15 & V600-H11 – 80 – 60 – 40 – Read/Write range (in transmission distance or transmission time priority mode) V600-D8KR12 & V600-H11 X 100 X – 80 – 60 V600-D8KR13 & V600-H11 X 100 – 80 – V600-D8KR04 & V600-H11 X 160 X – 100 – 80 – Electromagnetic Coupling RFID System – ...

Page 21

... N is the number of processing bytes. ■ Lower-Level Communications Mode Setting (Distance/Time Priority) The lower-level communications mode setting is made with a DIP Switch or memory switch on the Serial-interface Controller (V600-CA1A-@/ -CA2A-@, V600-CD1D-V3, V600-CMID Sensor Unit. (Refer to the Controller’s Operation Manual for more details on this setting.) With Parallel-interface Controllers (V600-CA8A-V2/CA9A-V2) the mode is fixed to transmission distance priority ...

Page 22

... Never short-circuit the positive and negative terminals of the bat- teries, charge the batteries, disassemble them, deform them, or throw them into a fire. Doing so may cause the batteries to ex- plode, combust, or leak liquid. Electromagnetic Coupling RFID System V600-D8KR04 (Typical Example) 1,000 500 300 100 ...

Page 23

... Side-by-side RD/WT command: 200 min. Auto command: 200 mm min. 200 mm min. V600-H52 • Facing min min. • Side-by-side min min. • Side-by-side min min. V600 V600-HS51 • Facing min. V600-HS51 V600-HS51 80 mm min. • Side-by-side min min. V600-HS51 V600-HS51 ...

Page 24

... Mutual Interference Between Proximity Sensors The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches, and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction sure to install the Units according to the distance restrictions specified in the following diagrams ...

Page 25

... V600-D23P53 R/W Head: V600-H52, V500-HS51 + V600-HA51, V600-HS61 + V600-HA51 40 mm min. V600-D23P55 R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 + V600-HA51 50 mm min. V600-D23P66N R/W Head: V600-H11 140 mm min. R/W Head: V600-H07 160 mm min. V600-D23P72 R/W Head: V600-H11 R/W Head: V600-H51 150 mm min. ...

Page 26

... V600-D8KR04 R/W Head: V600-H11 180 mm min. 180 mm min. V600-D2KR16 R/W Head: V600-H11 150 mm min min. R/W Head: V600-H07 160 mm min. 160 mm min. R/W Head: V600-H07 180 mm min. 160 mm min. R/W Head: V600-H07 220 mm min. Electromagnetic Coupling RFID System V600 ...

Page 27

... Battery-less DCs V600-D23P53 V600-D23P54 12 R0 dia. – 0.1 2-R1 – 0.1 Case: ABS resin Case: ABS resin Filler: Epoxy resin Filler: Epoxy resin V600-D23P66N 4-R4 25 ± 0.2 4- ± 0.2 Two, 3.5-dia. Two, 6-dia. 32 3.5 ± 0.1 34 Case: PPS resin 28 Electromagnetic Coupling RFID System V600-D8KR13 54 44± ...

Page 28

... Case: ABS resin Filler: Epoxy resin 10 Cable: PVC (oil-resistant) 11 Vinyl-insulated round cord (6-mm dia.) Bushing Connector 14.7 dia. 43 V600-HS51 (Sensor Section) M12X1 43 9.6 dia. 7 14.7 dia Connector Electromagnetic Coupling RFID System 4-R2 Case: Glass epoxy resin Coating: Polyurethane resin 43 14 ...

Page 29

... Operating indicator (orange) 22.6 22 51.7 5.9 61.8 Connector 13.7 dia. 36.5 23 51.3 ± Two, 4.5-dia. mounting holes 13.2 30 Electromagnetic Coupling RFID System V600-HS61 (Sensor Section) 30 14.7 dia. Detection surface Connector 10 Power indicator (green) 12.8 dia. 5 (10,000) 43 14.7 dia. Vinyl-insulated round cord Connector 6-mm dia (7/0 ...

Page 30

... Four, 3.5-dia. IDSC-C1D@-A (Stand-alone) 219 110 35.3 9.3 Four, 4.3-dia. 100 mounting holes 21.5 R/W Head connector 107 Electromagnetic Coupling RFID System V600-P01 Monitor Unit (For use with V600-CA@A-@) 80.6 120.6 22.6 V600-CB-US Handheld ID Controller 45.5 105 270 38 80 V600 31 ...

Page 31

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 32 Electromagnetic Coupling RFID System +50 44.9 0 24.99 32.2 Connector Vinyl-insulated flat cable dia. (12/0.18 mm dia.), 2-core, standard length: 0.19 m Attachment V600-A86 for V600-D23P66N Data Carriers 8-R0.5 24 ± 20 0.1 42 4-R5 3.5 8 ...

Page 32

... OMRON CANADA, INC. 885 Milner Avenue Toronto, Ontario M1B 5V8 416-286-6465 Specifications subject to change without notice Electromagnetic Coupling RFID System OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca Printed in USA V600 33 ...

Related keywords