v600-d2kr16 Omron Corporation, v600-d2kr16 Datasheet

no-image

v600-d2kr16

Manufacturer Part Number
v600-d2kr16
Description
Electromagnetic Coupling Rfid System
Manufacturer
Omron Corporation
Datasheet
Non-contact Data Communications System
• New compact, slim Controller with two input channels added to
• Superior environmental resistance.
• Heat-resistant Data Carrier available (150°C max.).
• Large memory capacity of 8 kbytes for Built-in-battery Data Car-
• Built-in-battery Data Carriers have a battery life detecting func-
• Data of Battery-less Data Carriers with small memory capacity
• Thin, compact, and low-cost Data Carriers are available.
• Transmission distance of 100 mm max.
• CE marking/FCC approvals.
Ordering Information
■ Data Carriers
Large Memory
Capacity
Small Memory
Capacity
the lineup.
riers and 254 bytes for Battery-less Data Carriers.
tion.
can be overwritten 300,000 times at normal temperatures.
Electromagnetic Coupling RFID System
V600
Built-in-battery Data Car-
riers
Battery-less Data Carri-
ers
Replaceable-battery Data
Carriers
Battery-less Data Carri-
ers
Item
V600-D8KR12
V600-D8KR13
V600-D8KR04
V600-D8KF04
V600-D2KR16
V600-D23P71
V600-D23P72
V600-D23P66N
V600-D23P66SP
V600-D23P61
V600-D23P53
V600-D23P54
V600-D23P55
Model
Electromagnetic Coupling RFID System
Rectangular compact
65 × 40 × 15 mm
Thin rectangular
86 × 54 × 10.3 mm
Intermediate-range rectangular
86 × 54 × 20 mm
Intermediate-range rectangular
86 × 54 × 20 mm
Compact
65 × 40 × 5 mm
Ultrathin card-type
86 × 54 × 1.5 mm
Thin half-size card-type
50 × 34 × 1.5 mm
Rectangular
34 × 34 × 3.5 mm
Rectangular package with PFA
95 × 36.5 × 6.5 mm
Rectangular compact
32 × 24 × 6 mm
Round super-compact
8 dia. × 5 mm
Round compact
12 dia. × 6 mm
Round super-compact
8 dia. × 5 mm
Specifications/Design/Memory capacity
V600
8 Kbytes
2 Kbytes
254 bytes
1

Related parts for v600-d2kr16

v600-d2kr16 Summary of contents

Page 1

... Battery-less Data Carri- ers Replaceable-battery Data Carriers Small Memory Battery-less Data Carri- Capacity ers Model V600-D8KR12 V600-D8KR13 V600-D8KR04 V600-D8KF04 V600-D2KR16 V600-D23P71 V600-D23P72 V600-D23P66N V600-D23P66SP V600-D23P61 V600-D23P53 V600-D23P54 V600-D23P55 Electromagnetic Coupling RFID System Specifications/Design/Memory capacity Rectangular compact 8 Kbytes 65 × 40 × Thin rectangular 86 × ...

Page 2

... V600-H07 (5 m) V600-H07 (10 m) V600-H11 (0.5 m) V600-H11-R (0.5 m) V600-H11 (2 m) V600-H11 (5 m) V600-H11 (10 m) Cylinder type V600-H51 (0.5 m) V600-H51 (2 m) V600-H51 (5 m) V600-H51 (10 m) V600-H52 (0.5 m) V600-H52 (2 m) V600-H52 (5 m) V600-H52 (10 m) Separate-amplifier Amplifier V600-HA51 (2 m) type section V600-HA51 (5 m) V600-HA51 (10 m) Sensor V600-HS51 section V600-HS61 ■ ...

Page 3

... Model Standard cable Non-water-resistant connectors Robotic cable Non-water-resistant connectors For the V600-D2KR16 *Mount with M3 flat countersunk head screws (at least two). For the V600-D23P71/D23P72 Ultrasonic deposition can be used on the plastic container. For the V600-D23P66N ■ Connectors for ID Controllers (One Set per Unit) ...

Page 4

... Approx 6.5 g Approx Approx. 5.8 g Approx. 0.4 g Approx. 1.0 g Approx. 0.6 g V600 Rectangular Round Round Compact Super- Compact compact V600- V600- V600- D23P61 D23P53 D23P54 − ° C IEC 60529: IP67 2 accel- Round Super- compact V600- D23P55 10 years ( − ...

Page 5

... Approx. 160 g Electromagnetic Coupling RFID System Battery-less Replaceable-battery Rectangular Rectangular Intermediate Range Compact with Replaceable Battery V600-D8KF04 V600-D2KR16 2 KB FeRAM SRAM (nonvolatile memory) (volatile memory) 2 years (at 25 ° C) --- (See note 4.) (See note 2.) 1,000 million Unlimited (Does not affect battery life) − ...

Page 6

... Indicators Power: green; transmission: orange Weight Approx (with 10-m cable) Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52. 2. The connectors are not water-resistant. 6 Electromagnetic Coupling RFID System V600-H11/H11-R − ° C − ...

Page 7

... CRC in both directions (CRC: Cyclic Redundancy Check) error detection Indicators --- Weight Approx (with 2-m cable) Note: 1. Extension cables are also available. The maximum cable length for the V600-HA51. Extension cables are not available for the V600-HS51/HS61. 2. The connectors are not water-resistant. Sensor section V600-HS61 2 ...

Page 8

... Ground to 100 Ω or less. Ground Degree of protection IEC 60529: IP30 (panel mounted) Weight Approx. 300 g 8 Electromagnetic Coupling RFID System V600 Series V600-CD1D-V3 RS-232C 1 24 VDC 20.4 to 26.4 VDC 7.2 W max. 1,000 VAC, 50/60 Hz for 1 min between the points listed above; Leakage current max. ...

Page 9

... V600-IDSC Series Model Item Host interface RS-232C Possible number of R/W Heads 2 Power supply voltage 24 VDC Acceptable power supply voltage 19.2 to 28.8 VDC Power consumption 50 W max Ω min. (at 500 VDC) between power supply terminals and frame ground terminals Insulation resistance Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between power supply terminals and frame ground terminals with a de- tected current of10 mA max ...

Page 10

... These Data Carriers are for installa- tion on non-metallic surfaces only. V600-D23P71/72 R/W Head Data Carrier Iron Non-metallic (Resin, plastic, wood, etc.) Data transmission will be impossi- ble if the DC is installed directly on a metal surface. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. ...

Page 11

... Condition for DC and R/W head distance installation R/W Head Data Carrier Iron Non-metallic (Resin, plastic, wood, etc.) Data transmission will be impossi- ble if the DC is installed directly on a metal surface. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. V600 11 ...

Page 12

... V600-D23P61 Data Carrier V600-H51 R/W Head Iron Iron (SC, SS) V600-H11 V600-D23P61 R/W Head Data Carrier Iron Iron (SC, SS) The listed transmission distances also apply for installation on non- metallic surfaces. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. ...

Page 13

... Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. Installation Controller ...

Page 14

... Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. 14 Electromagnetic Coupling RFID System ...

Page 15

... R/W Head Metal Data Carrier Surface-mounted on metal Metal Data Carrier Flush-mounted in metal Metal The listed transmission distances also apply for installation on non- metallic surfaces. Refer to the V600 R/W Heads and SRAM Data Carri- ers Operation Manual (Cat. No. Z127) for details. V600 15 ...

Page 16

... Stationary Flush-mount- Moving V600-D8KF04 V600-H07 Stationary Flush-mount- Moving V600-H11 Stationary Flush-mount- Moving V600-D2KR16 V600-H11 Stationary Flush-mount- Moving Note: 1. When Data Carriers are flush-mounted in metal, the read/ write distance will depend on the distance (x) between the side of the DC and the metal surface. mm Flush-mounted ...

Page 17

... Data Carrier (Above 100) Distance from metal surface ( ) (mm) V600-D8KR04 Combined with V600-H11 100 ∞ 0 V600-D8KF04 Combined with V600-H11 100 Electromagnetic Coupling RFID System (Axial offset: ± 0 mm) R/W Head Data Carrier ∞ ...

Page 18

... Lower-level Communications Mode Setting (Distance/Time Priority) The lower-level communications mode is set with the DIP Switch or memory switch on the Serial-interface Controller (V600-CA5D02, V600-CD1D- V3, V600-CM1D Sensor Unit. (Refer to the Controller’s operation manual for more details on the setting.) Characteristic Data (Typical) ■ Transmission Range Note: The values shown in the following graphs are in millimeters ...

Page 19

... V600-D23P53 & V600-HS51 +V600-HA51 – 10 – V600-D23P54 & V600-HS51 +V600-HA51 – 15 – 10 – V600-D23P55 & V600-HS51 +V600-HA51 – 15 – 10 – Read range (in transmission distance priority mode) V600-D23P53 & ...

Page 20

... − 100 − 80 − 60 − 40 − Replaceable-battery Data Carriers with Large Memory Capacity V600-D2KR16 & V600-H11 – 80 – 60 – 40 – Read/Write range (in transmission distance or transmission time priority mode) 20 Electromagnetic Coupling RFID System V600-D8KR12 & V600-H11 ...

Page 21

... DC speed. DC Speed = (Distance travelled in the transmission range)/ (Lower-level communications time) RD001122……………* Response Lower-level Communications Time with Battery-less Data Carriers (Reference) (Battery-less Models Excluding V600- D8KF04) 2,500 2,000 1,500 1,000 500 ...

Page 22

... The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life. V600-D8KR12 (Typical Example) 5 years 8 years Number of bytes/transmission ■ Temperature and Battery Life V600-D2KR16 The battery life is two years at 25 ° C regardless of the relationship between the number of bytes read/written and the number of transmissions. Examples Showing Relationship between Battery Life and Temperature 2 ...

Page 23

... F (100 ° C), incinerate, or charge the batteries, or short-circuit their positive and negative terminals. V600-H11 • Facing RD/WT command: 200 mm min. Auto command: 200 mm min. 200 mm min. • Side-by-side RD/WT command: 200 mm min. Auto command: 200 mm min. 200 mm min. Electromagnetic Coupling RFID System V600 23 ...

Page 24

... Mutual Interference between Proximity Sensors The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches, and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction sure to install the Units according to the distance restrictions specified in the following diagrams ...

Page 25

... Facing: 100 mm min. Proximity Sensor V600-HS51 Proximity Sensor 100 mm min. Proximity Sensor V600-HS51 200 mm min. 150 mm min. Proximity Sensor Electromagnetic Coupling RFID System 100 mm min. V600-H11 V600-HS61 100 mm min. V600-HS61 Proximity Sensor Proximity Sensor 100 mm min. 100 mm min. V600-HS61 Proximity Sensor V600 25 ...

Page 26

... When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at the distances specified below. Reading/Writing V600-D23P53 R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 + V600-HA51 40 mm min. V600-D23P55 R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 + V600-HA51 50 mm min. V600-D23P66N R/W Head: V600-H11 140 mm min. R/W Head: V600-H07 160 mm min. ...

Page 27

... R/W Head: V600-H11 140 mm min. 140 mm min. V600-D8KR13 R/W Head: V600-H11 160 mm min. 160 mm min. V600-D8KR04/V600-D8KF04 R/W Head: V600-H11 180 mm min. 180 mm min. V600-D2KR16 R/W Head: V600-H11 150 mm min min. R/W Head: V600-H07 160 mm min. 160 mm min. R/W Head: V600-H07 180 mm min. 160 mm min. R/W Head: V600-H07 220 mm min ...

Page 28

... Case: ABS resin 15 8 Filler: Epoxy resin V600-D8KR04 86 31 Four, 4.5-dia. mounting holes 5 76 ± ± 0.2 Case: ABS resin 20 Filler: Epoxy resin 10 Replaceable-battery DCs V600-D2KR16 4-R1 R0.5 Case: ABS resin 5 Battery-less DCs V600-D8KF04 86 31 Four, 4.5-dia. mounting holes 5 76 ± ± 0.2 20 ...

Page 29

... Case: PPS resin Filler: Epoxy resin V600-D23P66SP Mounting Hole Dimensions 2-M3 36 ± 0.2 6.5 25 ± 0.2 0.1 2.5 max. V600-D23P72 34 1.5 Electromagnetic Coupling RFID System V600-D23P61 36 30 ± 0.1 24 R0.2 dia. Two, 3.5-dia. mounting holes 0 5 – 0.1 Case: ABS resin Filler: Epoxy resin Two, 5.5-dia. 4-R6 Mounting Hole Dimensions ...

Page 30

... Bushing Connector V600-H52 43 14.7 dia. 12 dia. Connector 2 lock washers Case: Brass Transmission window: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) V600-HS61 (Sensor Section) 13.7 dia. 18 49.5 Transmission surface 10 V600 43 14.7 dia. Vinyl-insulated Connector round cord (6-mm dia.) Case: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) ...

Page 31

... V600-HA51 (Amplifier Section) Operating indicator (orange) 22.6 22 51.7 5.9 Connector 13.7 dia. 36.5 23 Two, 4.5-dia. mounting holes 13.2 ID Controllers V600-CA5D02 (Compact) Two, 4.5-dia. mounting holes 105 V600-CD1D-V3 (Compact 115 V600-CM1D (Board-mounted) 102 16 57.4 95 86.3 107 Four, 3.5-dia. Power indicator (green) 12.8 dia. 61.8 5 (10,000 ...

Page 32

... Material: PPS resin 4-R5.5 25 ± Two, 4-dia. 0 ± Mounting Hole Dimensions 2-M3 25 ± 0.2 25 ± 0.2 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 32 Electromagnetic Coupling RFID System 8-R0 ± 42 0.1 9 3.5 8.5 4-R3 5 2.1 63.6 2.1 2 V600 ...

Page 33

READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in ...

Page 34

... Cat. No. Q124-E1-03 OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2007 All Rights Reserved. 2007. 3 ...

Related keywords