v600-d2kr16 Omron Corporation, v600-d2kr16 Datasheet - Page 6

no-image

v600-d2kr16

Manufacturer Part Number
v600-d2kr16
Description
Electromagnetic Coupling Rfid System
Manufacturer
Omron Corporation
Datasheet
■ Read/Write (R/W) Heads with Built-in Amplifier
Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52.
6
Item
Oscillation frequency
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
(destruction)
Shock resistance
Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.
Wireless transmission
error detection
Indicators
Weight
2. The connectors are not water-resistant.
Electromagnetic Coupling RFID System
Model
530 kHz
− 25 to 70 ° C
− 40 to 85 ° C
35% to 95%
35% to 95%
50 M Ω min. (at 500 VDC) between cable terminals and case
1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
IEC 60529: IP67
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s
Destruction: 500 m/s
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Power: green; transmission: orange
Approx. 1 kg
(with 10-m cable)
V600-H07
2
3 times each in X, Y, and Z directions (18 times total)
− 10 to 60 ° C
− 25 to 75 ° C
Approx. 650 g (with 10-m cable)
V600-H11/H11-R
V600
2
acceleration with 3 sweeps of 11 min each in X, Y, and Z directions
V600-H51
V600-H52