E2E-X1R5E2 Omron, E2E-X1R5E2 Datasheet - Page 14

Inductive Proximity Sensor

E2E-X1R5E2

Manufacturer Part Number
E2E-X1R5E2
Description
Inductive Proximity Sensor
Manufacturer
Omron
Series
E2Er
Datasheet

Specifications of E2E-X1R5E2

Sensor Input
Inductive
Sensing Range
1.5mm
Supply Voltage Range Dc
10V To 40V
Sensor Housing
Barrel
Supply Voltage Max
30VDC
Sensing Range Max
1.5mm
Switch Terminals
Cable
Supply Voltage Min
10VDC
Maximum Operating Temperature
+ 85 C
Supply Voltage
30 V
Output Voltage
2 V
Operating Supply Voltage
12 V to 24 V
Sensing Distance
1.5 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
200 mA
Features
High visibility indicator
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E2E-X@Y@ AC 2-Wire Models
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing
object
Response frequency
Power supply voltage
(operating voltage
range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient temperature
range *1*2
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight
Materials
Accessories
5 to 200 mA max.
*1
Load
current
Residual
voltage
Pre-
wired
Models
Model
Connec-
tor
Models
Case
Sensing
surface
Clamp-
ing nuts
Toothed
washer
Shielded
Model E2E-X1R5Y@
Size
*2
1.5 mm ±10%
0 to 1.2 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Iron,
8 × 8 × 1 mm
25 Hz
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
1.7 mA max.
5 to 100 mA
Refer to Engineering Data on page 20.
Operation indicator (red)
Y1 Models: NO
Y2 Models: NC
Surge suppressor
Operating/Storage: −25 to 70°C
(with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
±10% max. of sensing distance
at 23°C in the temperature range
of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
10 times each in X, Y, and
Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Approx. 60 g
Approx. 15 g
Stainless steel (SUS303)
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
Shielded
M8
E2E-X2MY@
2 mm ±10%
0 to 1.6 mm
Iron, 12 × 12 × 1 mm
Unshielded
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.
2
E2E-X2Y@
Operating/Storage: −40 to 85°C (with no icing or condensation)
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Destruction: 1,000 m/s
5 to 200 mA
Approx. 70 g
Approx. 25 g
Nickel-plated brass
Shielded
M12
E2E-X5MY@
5 mm ±10%
0 to 4 mm
Iron,
15 × 15 × 1 mm
Unshielded
2
10 times each in X, Y, and Z directions
E2E-X5Y@
Iron,
18 × 18 × 1 mm
5 to 300 mA
Approx. 130 g
Approx. 40 g
Shielded
M18
E2E-X10MY@
10 mm ±10%
0 to 8 mm
Iron, 30 × 30 × 1 mm
Unshielded
E2E-X10Y@
Approx. 175 g
Approx. 90 g
Shielded
M30
E2E-X18MY@
18 mm ±10%
0 to 14 mm
Iron,
54 × 54 × 1 mm
Unshielded
E2E
14