E2E-X1R5E2 Omron, E2E-X1R5E2 Datasheet - Page 31

Inductive Proximity Sensor

E2E-X1R5E2

Manufacturer Part Number
E2E-X1R5E2
Description
Inductive Proximity Sensor
Manufacturer
Omron
Series
E2Er
Datasheet

Specifications of E2E-X1R5E2

Sensor Input
Inductive
Sensing Range
1.5mm
Supply Voltage Range Dc
10V To 40V
Sensor Housing
Barrel
Supply Voltage Max
30VDC
Sensing Range Max
1.5mm
Switch Terminals
Cable
Supply Voltage Min
10VDC
Maximum Operating Temperature
+ 85 C
Supply Voltage
30 V
Output Voltage
2 V
Operating Supply Voltage
12 V to 24 V
Sensing Distance
1.5 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
200 mA
Features
High visibility indicator
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Pre-wired Models
(Shielded)
Diagram 4
Diagram 9
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 7
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 5
1.3 mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
diameter: 1.3 mm), Standard length: 2 m
diagnostic output.
1.3 mm), Standard length: 2 m
mm), Standard length: 2 m
1.27 mm), Standard length: 2 m
1.27 mm), Standard length: 2 m
diameter: 1.3 mm), Standard length: 2 m
21 dia.
15 dia.
15 dia.
17
13
13
8
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
M12 × 1
M5 × 0.5
section: 0.14 mm
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.15 mm
The cable can be extended up to 100 m (separate metal conduit).
9.7 dia.
M8 × 1
M8 × 1
E2E-X1B@/X1C@
E2E-X3D@
E2E-X2E@/F@
E2E-X1R5Y@
E2E-X2D@
E2E-X1R5E@/F@
3
3
4
4
17.5
33
15
26
Toothed
washer
38
Toothed washer
30
Two clamping nuts
25
36
2
2
Toothed washer
, Insulator diameter: 0.9 mm), Standard length: 2 m
, Insulator diameter: 1.05 mm), Standard length: 2 m
Two clamping nuts
Two clamping nuts
40
8
Two toothed washers
10
Two clamping nuts
Operation indicator (red)
8
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
7
Indicators
Operation indicator (red)
9
Indicators * 2
7
Pre-wired e-CON Connector Models
*2
*1
*
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
*
*1
2
2
2
, Insulator diameter: 1.3
, Insulator diameter: 1.27
, Insulator diameter: 1.27
2
2
2
15.6
, Insulator diameter: 1.3
, Insulator diameter:
, Insulator diameter:
2
2
, Insulator diameter:
, Insulator
Mounting Hole Dimensions
2
, Insulator diameter:
2
, Insulator
2
, Insulator
1
2
3
4
5.9
15
F
Diagram 6
Pre-wired Models (Unshielded)
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 8
Diagram 10 E2E-X8MD@
15 dia.
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
15 dia.
13
1.3 mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
21 dia.
1.3 mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
mm), Standard length: 2 m
diagnostic output.
13
17
6.1 dia.
6.1 dia.
9 dia.
M8 × 1
Dimension
M8 × 1
M12 × 1
F (mm)
6
6
E2E-X4MD@
E2E-X2ME@/F@
E2E-X2MY@
E2E-X5ME@/F@
7
3
26
3
30
Toothed washer
Toothed
washer
4
33
36
40
38
8
Two clamping nuts
Two clamping nuts
Toothed washer
Indicators *2
8
10
Two clamping nuts
7
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm
1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
5.5
Operation indicator (red)
+0
7
M5
0
.
9
5
Indicators *2
Pre-wired e-CON Connector Models
dia. 8.5
*1
*
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
+0.5
M8
0
*1
dia. 12.5
2
, Insulator diameter:
2
2
2
2
2
2
, Insulator diameter: 1.3
, Insulator diameter: 1.27
, Insulator diameter: 1.27
15.6
, Insulator diameter: 1.3
, Insulator diameter: 1.27
, Insulator diameter: 1.27
2
, Insulator diameter:
2
, Insulator diameter:
1
2
3
4
M12
+0.5
E2E
0
5.9
15
dia.
31

Related parts for E2E-X1R5E2