E2E-X1R5E2 Omron, E2E-X1R5E2 Datasheet - Page 17

Inductive Proximity Sensor

E2E-X1R5E2

Manufacturer Part Number
E2E-X1R5E2
Description
Inductive Proximity Sensor
Manufacturer
Omron
Series
E2Er
Datasheet

Specifications of E2E-X1R5E2

Sensor Input
Inductive
Sensing Range
1.5mm
Supply Voltage Range Dc
10V To 40V
Sensor Housing
Barrel
Supply Voltage Max
30VDC
Sensing Range Max
1.5mm
Switch Terminals
Cable
Supply Voltage Min
10VDC
Maximum Operating Temperature
+ 85 C
Supply Voltage
30 V
Output Voltage
2 V
Operating Supply Voltage
12 V to 24 V
Sensing Distance
1.5 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
200 mA
Features
High visibility indicator
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing ob-
ject
Response frequency
Power supply voltage
(operating voltage
range)
Current consumption
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient
temperature range
Ambient humidity
range
Temperature influ-
ence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
a set distance of half the sensing distance.
Load
current
Residual
voltage
Case
Sensing
surface
Clamping
nuts
Toothed
washer
Shielded
Model
Size
*
0.6 mm ±15%
0 to 0.4 mm
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Iron, 3 × 3 × 1 mm
2 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
10 mA max.
Open-collector output,
80 mA max. (30 VDC max.)
1 V max.
Cable length: 2 m)
Operation indicator (red)
C1/B1 Models: NO
C2 Models: NC
Reverse polarity protection, Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±5% max. of sensing distance at
rated voltage in the rated voltage
±10% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP66
Pre-wired Models (Standard cable length: 2 m)
Approx. 60 g
Stainless steel (SUS303)
Heat-resistant ABS
Nickel-plated brass (E2E-X1C/B@ only)
Zinc-plated iron (E2E-X1C/B@ only)
Instruction manual
(Load current: 80 mA,
E2E-CR6C/B@
3 dia.
2
10 times each in X, Y, and Z directions
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.
0.8 mm ±15%
0 to 0.5 mm
Iron, 5 × 5 × 1 mm
3 kHz
17 mA max.
Open-collector output, 100 mA max. (30 VDC max.)
2 V max. (Load current: 100 mA, Cable length: 2 m)
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
IEC 60529 IP67, in-house standards: oil-resistant
E2E-CR8C/B@
4 dia.
Shielded
1 mm ±15%
0 to 0.7 mm
Nickel-plated brass
E2E-X1C/B@
M5
E2E-C1C/B@
5.4 dia.
E2E