E2E-X1R5E2 Omron, E2E-X1R5E2 Datasheet - Page 6

Inductive Proximity Sensor

E2E-X1R5E2

Manufacturer Part Number
E2E-X1R5E2
Description
Inductive Proximity Sensor
Manufacturer
Omron
Series
E2Er
Datasheet

Specifications of E2E-X1R5E2

Sensor Input
Inductive
Sensing Range
1.5mm
Supply Voltage Range Dc
10V To 40V
Sensor Housing
Barrel
Supply Voltage Max
30VDC
Sensing Range Max
1.5mm
Switch Terminals
Cable
Supply Voltage Min
10VDC
Maximum Operating Temperature
+ 85 C
Supply Voltage
30 V
Output Voltage
2 V
Operating Supply Voltage
12 V to 24 V
Sensing Distance
1.5 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
200 mA
Features
High visibility indicator
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E2E Model Number Legend
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
No.
A
B
C
D
E
F
G
H
I
J
K
L
M
E2E-
Models are not available for all combinations of code numbers.
Ask your OMRON representative if you require a customized model.
Appearance
Sensing distance
Shielding
Power supply and output
specifications
Form of output switching el-
ement
Oscillation frequency type
Self-diagnosis
Connection method
Connector specifications
DC 2-wire polarity
Cable specifications
New model
Cable length
A B C D E F G
Classification
Letter M
Number
Code
Blank
Blank
Blank
Blank
Blank
Blank
Blank
TGJ
M1
M3
GJ
TJ
M
G
C
X
R
B
C
D
E
F
T
Y
T
R
U
N
1
2
5
5
J
-
H I - J - K - L
Cylindrical (not threaded)
Cylindrical (threaded)
Sensing distance (Unit: mm)
Indication of decimal point
Shielded Models
Unshielded Models
DC 3-wire PNP open-collector output
DC 3-wire NPN open-collector output
DC 2-wire polarity/no polarity
DC 3-wire NPN collector load built-in output
DC 3-wire PNP collector load built-in output
AC/DC 2-wire
AC 2-wire
Normally open (NO)
Normally closed (NC)
Standard frequency
Different frequency
No
Yes
Pre-wired
M12-size metal connector
M8-size metal connector
Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement (polarity)
Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno-
sis output, DC 2-wire with old pin arrangement (polarity)
Pre-wired Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (no polarity)
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Polarity
No polarity
Standard PVC cable (oil resistant)
Flexible PVC cable (oil resistant)
Polyurethane cable (oil resistant and reinforced)
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
wired Connector Models.)
Meaning
M
Example:
Whether D models have
polarity is defined by num-
ber J.
Used to prevent mutual in-
terference.
This is blank if the cable
specification in number K
is R or U.
Example:
R6: 0.6 mm
1R5: 1.5 mm
2M
0.3M
Remarks
E2E
6

Related parts for E2E-X1R5E2