DP-101-E-P SUNX, DP-101-E-P Datasheet - Page 7

PRESSURE SENSOR, -1TO1BAR, PNP, 2M

DP-101-E-P

Manufacturer Part Number
DP-101-E-P
Description
PRESSURE SENSOR, -1TO1BAR, PNP, 2M
Manufacturer
SUNX
Datasheet

Specifications of DP-101-E-P

Svhc
No SVHC (18-Jun-2010)
Response Time
2.5ms
Contact Configuration
Connecting Cable, 2m
External Depth
42.5mm
External Length / Height
30mm
External Width
30mm
Ip/nema Rating
IP40
Lead
RoHS Compliant
Switching is possible between analog voltage output and external input
Multi-function type is available that allows selection of analog voltage output or external input (auto-reference / remote zero-adjustment).
This is suitable for multi-specification applications.
Equipped with auto-reference / remote zero-adjustment functions
More precise pressure management is possible with a minimum of effort
If the reference pressure of the
device
reference function partially shift
the
judgment level by the amount
that the reference pressure
shifts, and the remote zero-
adjustment function can reset
the display value to zero via
external input. These functions
are ideal for places where the
reference pressure fluctuates
wildly, or where fine settings are
desired.
When auto-reference input is applied, the reference pressure ‘30’ is added
to the threshold level. If the reference pressure changes to ‘20’ or ‘40’, the
auto-reference input compensates for this every time by changing the
threshold level, so any variation in the filling pressure can be ignored.
Pressure
Multi-function type
comparative
Comparative output: Window comparator mode
changes,
30
25
20
15
0
5
Time
With auto-reference function applied
Auto-reference input
the
output
Sets the absolute threshold level
Hi-1 0, Lo-1
auto-
Threshold level before applying
auto-reference input
Auto-reference input value
The display remains at ‘30’ and
only the threshold level is changed.
Select
5
Threshold level after applying
auto-reference input
Trial 1
OK
Analog voltage output
Comparative output
External input
Without auto-reference and remote zero-adjustment functions
Pressure
When remote zero-adjustment input is applied, the reference pressure is forced to ‘0’.
If the reference pressure changes to ‘20’ or ‘40’, the remote zero-adjustment input
adjusts the reference pressure to ‘0’ every time the reference pressure changes, so
any variation in the filling pressure can be ignored.
Because the threshold level is fixed for conventional pressure sensors,
changes in the reference pressure result in wrong decisions.
Pressure
or
Comparative output: Window comparator mode
30
25
20
15
Comparative output: Window comparator mode
40
30
25
20
15
With remote zero-adjustment function applied
0
5
0
Time
Time
Remote zero-adjustment input
Variation in the filling pressure
Low pressure type: 1 to 5 V
High pressure type: 0.6 to 5 V
Auto-reference /
remote zero-adjustment
ANALOG
0
5
Multi-function type
Hi-1 0, Lo-1
Sets the absolute threshold level
Threshold level before applying
remote zero-adjustment input
Hi-1 30, Lo-1 25
Fixed set value
lights up
The display is forced to ‘0’, and only the
filling pressure drop range is displayed.
Displayed when remote zero-
Multi-function type
Leak threshold level
adjustment input is applied
Threshold level after applying
remote zero-adjustment input
5
Trial 1
Trial 2
Trial 3
Trial 1
OK
NG?
OK
NG?
6

Related parts for DP-101-E-P