RP-RM83F-38LR BANNER ENGINEERING, RP-RM83F-38LR Datasheet

no-image

RP-RM83F-38LR

Manufacturer Part Number
RP-RM83F-38LR
Description
Heavy-Duty Emergency Stop Rope Pull
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-RM83F-38LR

Ring Attachment
38 Meter Max. Range
Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Model
Original Instructions
RP-RM83F-75LTE
RP-RM83F-75LRE
RP-RM83F-75LT
RP-RM83F-75LR
RP-RM83F-38LTE
RP-RM83F-38LRE
RP-RM83F-38LT
RP-RM83F-38LR
NOTE: This symbol
diagram to identify the point in actuator travel where the normally-closed safety contact is fully
open.
for a positive-opening safety contact (IEC 60947-5-1) is used in the switching
Max. Rope
Length
37.5 m
(245')
(123')
75 m
Rope Connection
Built-in Turnbuckle
Built-in Turnbuckle
Built-in Turnbuckle
Built-in Turnbuckle
RP-RM83F-.. Heavy-Duty Rope Pulls
With E-Stop Button, for Indoor or Outdoor Use
Contacts latch open when rope is pulled or in case of a broken wire;
requires manual reset
Aluminum die-cast housing, rated IP67 and NEMA 4, suitable for
demanding indoor and outdoor industrial environments
Innovative RP-RM83F-..LT.. design for quick, easy rope adjustment
Rope spans up to 75 m (245'), depending on model
Both Safety contacts are closed with normal rope tension, and open when
the rope is pulled, if it breaks, or if tension is reduced
Both Monitoring contacts operate opposite the safety contacts, for
monitoring by another device
Additional Aux. 24V solid-state PNP output on some models provides
remote rope tension monitoring
Tension indicator window indicates proper rope tension for operation or
safety contacts latched open (the rope pull or the E-stop button is actuated)
Ring
Ring
Ring
Ring
Models
Aux.
Status
Output
Yes
Yes
No
No
Run
Position
Cable Run Position (All
Cable Pulled / Cable
Break Position (All
S1
S1
11
23
11
23
Models)
Models)
12
24
12
24
Cable
Pulled/
Cable Break
11
23
11
23
S2
S2
12
24
12
24
Switching
Diagram
No PNP Aux.
Output Models
PNP Aux.
Output Models
Break (91N/156N)
Break (91N/156N)
Pull (175N/300N)
Pull (175N/300N)
Latch
Latch
Latch
Latch
133N/228N
133N/228N
Set Point
Set Point
Open
Tension
Tension
0 141245 1
S1
S1
S2
S2
Aux.
-6
-4.8
-4
+4
+4.8
+6
mm
Closed
-6
-4.8
-4
-3
+3
+4
+4.8
+6
mm

Related parts for RP-RM83F-38LR

RP-RM83F-38LR Summary of contents

Page 1

... RP-RM83F-75LR RP-RM83F-38LTE RP-RM83F-38LRE 37.5 m RP-RM83F-38LT (123') RP-RM83F-38LR NOTE: This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switching diagram to identify the point in actuator travel where the normally-closed safety contact is fully open. RP-RM83F-.. Heavy-Duty Rope Pulls With E-Stop Button, for Indoor or Outdoor Use Contacts latch open when rope is pulled or in case of a broken wire ...

Page 2

... Occupational Safety and Health Administration (OSHA). Whether or not any particular rope pull switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the switches are applied, installed, wired, operated, and maintained. ...

Page 3

... When used separately, these contacts provide inputs to a dual-channel safety module. Terminals 11/12 can also be used individually to provide single-channel switching single-channel input to a safety module. Terminals 23/24 are for monitoring purposes only (closed in a cable-break/cable-pull situation). When the rope is properly tensioned (228 or 133N, depending on model), the red arrows are centered under the hash mark on the tension indicator window, the contacts at terminals 11/12 are closed, and the contacts at terminals 23/24 are open. All models feature “ ...

Page 4

... All hardware is supplied by the user. See Dimensions for switch mounting hole mounting pattern and size. 4 P/N 141245 rev. A 01/09 Mechanical Installation Guidelines Installation Procedure 400 mm (16") max. for actuation of switch Note: Force to actuate must not exceed 200 N (45lbf) Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 Spring breakage protector cable 340 mm L3 ...

Page 5

... Models RP-RM83F-..LR and RP-RM83F-..LRE: Turn the turnbuckle until the arrows are centered. Models RP-RM83F-..LT and RP-RM83F-..LTE: Turn the shaft of the switch using wrench as shown, until the arrows are centered. Pull hard on the rope and reset the latch several times. If the arrows in the tensioning indicator window do not return to the correct position (centered on the line in the window), further tighten or loosen the rope tension as needed, then reset, until proper tension is shown ...

Page 6

... P/N 141245 rev. A 01/09 Electrical Installation PNP 10-30 VDC 1 Warning Signal + 1 2 Load 2 3 – 3 Connections Figure 6: Warning signal electrical connections Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 Dual-Channel Connection Channel A Channel 10-30 VDC Load 2 3 – 3 +24V 1 ...

Page 7

... Pack the rope pull switch carefully. Damage which occurs in return shipping is not covered by warranty. Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 RP-RM83F-.. Heavy-Duty Rope Pulls E-Stop Reset ...

Page 8

... Temperature: -30° to +80° C (-34° to +176° F) RP-RM83F-..LT and -..LTE (2.1 lbs.) RP-RM83F-..LR and -..LRE: 0.77 Kg (1.6 lbs.) DIN EN 60947-1, DIN EN 60947-5-1, DIN EN 60947-5-5, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-5, ISO 13850 Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 40- Ie/AC-15 A Ie/DC-13 ...

Page 9

... Category Certifications RP-RM83F-..LR.. 8.5 mm (0.33") 20.5 mm (0.80" (1.9") (1.6" (0.4") max. 197 mm / min. 185 mm Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 RP-RM83F-.. Heavy-Duty Rope Pulls Description Dimensions 88 mm (3.5" (2.1") 20.5 mm 20.5 mm (0.80") (0.80") 30.5 mm M20 x 1.5 20.5 mm (1.20") (0.80" Ø ...

Page 10

... RPA-EB1 RPA-P1 RPA-DP1 Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 Description 2 mm steel wire rope with 0.5 mm red PVC jacket (unterminated steel wire rope with 0.5 mm red PVC jacket (unterminated 4 mm steel wire rope with 0.5 mm red PVC jacket (unterminated) ...

Page 11

... Models Tensioning Springs Tensioning Spring Assemblies Cable Gland Conduit Adaptor Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 RP-RM83F-.. Heavy-Duty Rope Pulls Package Qty. RPA-S3 RPA-S5 RPA-S4 RPA-S6 SI-QM-CGM20 1 pc SI-QM-M20 1 pc Description Tensioning spring #3 for use with model RP-RM83F-..75.. ...

Page 12

... Yodogawa-Ku, Osaka TAIWAN Tel: 532-0011 JAPAN Tel: 886-2-8751-9966 Fax: 81-6-6309-0411 Fax: 886-2-8751-2966 81-6-6309-0416 www.bannerengineering.com.tw www.bannerengineering.co.jp info@bannerengineering.com.tw mail@bannerengineering.co.jp Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164 Europe Latin America Contact Banner Engineering Corp. (US) or e-mail Mexico: mexico@bannerengineering.com Brazil: brasil@bannerengineering.com Asia India Banner Engineering India Pune Head Quarters Office No ...

Related keywords