Specifications of RP-RM83F-38LR

Ring Attachment
38 Meter Max. Range
Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
4
P/N 141245 rev. A 01/09
RP-RM83F-.. Heavy-Duty Rope Pulls
1. Mount the switch securely on a solid, stationary surface.
2. Fasten an eye bolt at the opposite end of the rope span from the switch. Verify that the anchor for the eye
3. Assemble the rope, as shown. Keep the rope’s PVC cover intact along its complete length, except where
4. Use pulleys (recommended) or eye bolts at each support point. Always use a pulley when routing the rope
Figure 2: Assembly of rope and hardware (see Accessories section for components)
All hardware is supplied by the user. See Dimensions for switch mounting hole mounting pattern and size.
The wire rope should be easily accessible and visible along its entire length. Markers or flags may be fixed
on the rope to increase its visibility.
Mounting points, including support points, must be rigid.
The rope should be free of friction at all supports. Pulleys are recommended.
Use only pulleys (not eye bolts) when routing the rope around a corner, or whenever direction changes,
even slightly.
Never run rope through conduit or other tubing.
Never attach weights to the rope.
Temperature affects rope tension. The rope expands (lengthens) when temperature increases, and
contracts (shrinks) when temperature decreases. Significant temperature variations require frequent
checks of the tension adjustment.
Do not exceed the maximum specified total rope length. Banner offers models for other spans; contact
the factory or visit www.bannerengineering.com for model selection.
bolt is solid and stationary, to withstand the constant tension and possible pull of the rope.
it attaches to the clamps at either end.
around a corner, regardless of the angle.
L3
Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164
Mechanical Installation Guidelines
for actuation of switch
400 mm (16") max.
Installation Procedure
L1
L4
L4
Note:
Force to actuate must
not exceed 200 N (45lbf)
L2
L1
L2
Spring breakage
protector cable
L3
340 mm

Related parts for RP-RM83F-38LR