RP-RM83F-38LR BANNER ENGINEERING, RP-RM83F-38LR Datasheet - Page 7

no-image

RP-RM83F-38LR

Manufacturer Part Number
RP-RM83F-38LR
Description
Heavy-Duty Emergency Stop Rope Pull
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-RM83F-38LR

Ring Attachment
38 Meter Max. Range
Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Banner Engineering Corp. - Minneapolis, MN U.S.A. - www.bannerengineering.com - Tel: 763.544.3164
Test each rope pull emergency stop installation for proper machine shutdown response at each shift change
or machine setup; this should be performed by a Designated Person*. In addition, a Qualified Person* should
check for proper rope tension and adjust as needed, on a periodic schedule determined by the user, based
upon severity of the operating environment and the frequency of switch actuations.
Periodically lubricate the pulleys and other moving parts associated with the rope. If inspection reveals dirt
on the rope pull switch or rope assembly, clean off the dirt and eliminate its cause. Replace the rope pull
switch and/or rope assembly when any parts (including contacts) or assemblies are found to be damaged,
broken, deformed, or badly worn.
Replace the rope pull switch and rope assembly at specified intervals, based upon the environment and
operating conditions. Consider replacement of the rope pull switch and rope assembly after no more than
100,000 operations. Always test the control system for proper functioning under machine control
conditions after maintenance or replacement of the rope pull switch.
* A Designated Person is identified in writing by the employer as being appropriately trained to perform a
specified checkout procedure. A Qualified Person possesses a recognized degree or certificate or has
extensive knowledge, training, and experience to be able to solve problems relating to the emergency stop
rope pull switch installation.
Do not attempt any repairs to the rope pull emergency stop switch. It contains no field-replaceable
components. Return it to the factory for warranty repair or replacement, as follows.
Contact Banner Factory Application Engineering at the address or the numbers listed on the back page. They
will attempt to troubleshoot the system from your description of the problem. If they conclude that a component
is defective, they will issue a return merchandise authorization (RMA) number for your paperwork, and give
you the proper shipping address.
Pack the rope pull switch carefully. Damage which occurs in return shipping is not covered by warranty.
E-Stop and Latch Reset
After the rope is pulled or the E-stop button is
pressed, the latch must be reset.
The E-stop can be reset only when proper tension
is indicated. Pull the red E-stop button until the
switch Status indicator changes from Yellow to
Green and the latch makes an audible “click,”
indicating that the latch has been reset.
NOTE: Proper rope tension must be displayed
before the latch can be reset.
E-Stop Reset
Maintenance
Repairs
Figure 7: Resetting the latch
RP-RM83F-.. Heavy-Duty Rope Pulls
P/N 141245 rev. A 01/09
7