CPM1A-20CDR-A-V1 Omron, CPM1A-20CDR-A-V1 Datasheet - Page 19

Micro Programmable Logic Controller

CPM1A-20CDR-A-V1

Manufacturer Part Number
CPM1A-20CDR-A-V1
Description
Micro Programmable Logic Controller
Manufacturer
Omron
Datasheets

Specifications of CPM1A-20CDR-A-V1

Output Type
Relay
External Width
86mm
Supply Voltage Max
240VAC
External Depth
70mm
Mounting Type
DIN Rail
External Height
90mm
Supply Voltage Min
100VAC
Approval Bodies
UL, CSA, CE
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J INTERVAL TIMER INTERRUPTS
The CPM1A has one interval timer. The interval timer shuts down the regular program regardless of the point in the cycle once the time is
up, and immediately executes an interrupt processing program. Interval timers are used in the following two modes.
J ANALOG SETTING
The CPM1A contains two analog setting controls that can be used for a broad range of analog timer and counter settings. Turning the
setting control stores values of 0 to 200 (BCD data) in the SR area.
*Phillips screwdriver is required
to turn analog adjustment knobs.
Item
Operation
Setting time
Analog setting
Analog setting 0
Analog setting 1
A--40
Normal program
Analog setting 0
Analog setting 1
Micro Programmable Controller
One-shot mode
An interrupt is executed only once when the time is up.
0.5 ms to 319,968 ms (0.1-ms units)
MOV(21)
ADD(30)
END(01)
Interrupt processing program
Storage area
SR 250
SR 251
Interval timer
CPM1A
SBN(92) 00
MOV(21)
RET(93)
Application Example:
Tact Operation Control of Conveyor Lines
A conveyor can be stopped temporarily as required for assembly
processes. When the timer function and limit switches are used
in a combination, conveyors can be stopped for a fixed time or
can be run at a constant speed for a fixed distance. Fine
adjustment of the stopping time can be easily done by using the
analog setting controls.
Scheduled interrupt mode
Interrupts are executed repeatedly at fixed periods.
CPM1A
Application Example:
Computing the Sheet Speed
The number of pulse inputs is computed
in the interrupt mode at a fixed time to
calculate the speed.
Setting value (BCD)
0000 to 0200
LS
Motor
Encoder
CPM1A