CV500CN228 Omron, CV500CN228 Datasheet

no-image

CV500CN228

Manufacturer Part Number
CV500CN228
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN228

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
NT-series
Host Interface Unit
Direct Connection
Operation Manual
Produced September 1993

Related parts for CV500CN228

CV500CN228 Summary of contents

Page 1

NT-series Host Interface Unit Direct Connection Operation Manual Produced September 1993 ...

Page 2

...

Page 3

... All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “ ...

Page 4

...

Page 5

...

Page 6

4   #  !  '  ' #  (     * (   - "#  +    +  %      . $.    ...

Page 7

... Support Tool. Section 5 describes how to convert existing screen data for use with Direct Connection and how to con- vert a PC program written for Direct Connection OFF for use with Direct Connection OMRON. Section 6 describes the procedures to follow if the PT does not operate correctly. ...

Page 8

&  %  &  % #   &     6 %   &#  &   % & / *                  ( % "#    *#   ...

Page 9

Getting Starting To ensure that the Host Interface Unit works correctly, carefully observe the fol- lowing when positioning and handling it. Location Do not install the Host Interface Unit in a location subject to the following condi- tions: Handling ...

Page 10

... EEPROM: EER22-20 1-2 Programmable Terminal The OMRON Programmable Terminal (PT) displays the status and other in- formation about the FA-applied factory. The PT is briefly described below. 1-2-1 Role and Operation The Programmable Terminal (PT factory terminal device which commu- nicates with Programmable Controllers (PCs) and displays the operating status of machines and other equipment, work instructions, and operations of the PT ...

Page 11

Production Line Status The PT displays real-time information about the system and equipment operat- Monitoring ing status and manufactured quantity. Messages The PT warns of system or equipment errors with a display and buzzer, and prompts the appropriate remedial action. ...

Page 12

Displays The PT can display the following items to provide the operations mentioned pre- viously. Each of these items is called a “display element.” Character string memory table setting Text Bar graph    Text Characters which remain unchanged ...

Page 13

The Host Interface Unit reads instructions to switch screens from the PC memory area and controls the PT. It reads the status of the PT and writes it to the PC memory area. 1-3-2 Direct Connection Function The new Direct ...

Page 14

PC and increases the efficiency of program develop- ment. Refer to Section 3 Direct Connection Operation and Section 4 PT Operation for details on the Direct Connection function. Direct Connection Examples are presented below of ...

Page 15

... RS-232C Cable Section 2 Installation and Settings Appendix D RS-422 Connections RS-422 Cable Optical Fiber Cable Appendix E Optical Fiber Cable Connections OMRON PC: Controls the PT as required while controlling machines and monitoring the production line. IBM PC/AT or compatible Computer (Support Tool): Can be connected to the PT when required to transfer prepared PT screens and settings ...

Page 16

Before Operating Follow the procedure indicated below before operating a PT with Host Interface Unit installed. PC Check and change the PC settings. Refer to the appropriate PC Manual Create the PC program. Refer to the appropriate PC Manual ...

Page 17

Reference Manuals The NT20M/NT2000M Series and NT600M Series are covered in the six manuals described below. Name of Manual NT20M/NT2000M Operation This manual provides specifications, functions, and operating Manual instructions for the NT20M and NT2000M Programmable Terminals. NT600M Operation Manual ...

Page 18

&  %  &/   &      & & & # %   * # % +  #  * /&     &          ...

Page 19

Components and Settings The parts of the Host Interface and how to set the operating environment are described below. 2-1-1 Description and Function of Components The names and functions of the Host Interface parts are shown in the diagram ...

Page 20

... Note 1. Turn off the power supply before setting the operating environment with the 2. Be sure to correctly set the communication conditions. Communication is 3. Use the cables recommended by OMRON to connect the units. Incorrect 2-2 Installing the Host Interface How to install the Host Interface in the PT. ...

Page 21

Installation in the NT600M How to Remove the Unit Hold the unit by the indentations at each side, press inwards and pull out the unit. Removal from the NT600M Note Turn off the PT power supply when installing or removing ...

Page 22

... Note Turn off the power supply before setting the DIP switches. 2-3 Connection to an OMRON PC Connect the PT fitted with the Host Interface to the OMRON PC with an RS-232C. 2-3-1 Compatible PCs Some models and series of OMRON PCs have the Host Link function built-in. ...

Page 23

... Connecting the PT OMRON provides two types of connector cables. Refer to the diagrams below to select the appropriate cable for the unit connec- tors. Connect the PT to the PC. Note Turn off the PT and PC power supplies before inserting or removing connectors. Connecting with Use the following connector cable with a 25-pin connector at each end to con- ...

Page 24

Connecting the Two types of connector are found on CV500-LK201 Host Link Units. Both of or CVM1 Series Host Link these connector types can be connected with an RS-232C connector cable. Se- Unit lect the connector ...

Page 25

Refer to the manual on each unit for more detailed in- formation on making these settings. I/O port Baud rate Transfer code Parity 1-to-1/1-to-N Instruction level Unit# Note The 1-to-N setting enables BCC (Block Check Character). ...

Page 26

Setting the Rear Switches CTS selector switch External C500(F), C1000(F) C500-LK201-V1 Rack-mounting Types Setting the Rear Switches RS-422 I/O port RS-232C Synchronization Internal External OFF Termination ON resistance 0 V CTS External (ON) I/O ...

Page 27

C500(F), C1000(F) C500-LK203 Rack-mounting Types Setting the Rear Switches supply OFF RS-422 I/O port RS-232C Internal Synchronization External Termination OFF resistance CTS External I/O port selector switch Always set to RS-232C. DIP switch SW1: ...

Page 28

CPU-mounted Type C120-LK201-V1 Setting the Rear Switches SW1 SW2 SW3 Baud rate 19,200 bps DIP switch SW3: Synchronization and CTS setting CV Series Backplane CV500-LK201 Mounted Type Setting the Front Switches Set the operating conditions with the PC System Setting ...

Page 29

Set the DIP switches to enable the system settings to be made. Communication port 1: RS-232C Communication port 2: RS-232C, RS-422 Connection to a CPU Set the operating conditions with the PC System Setting functions when con- necting to a ...

Page 30

Front Switch Settings When connecting to a CV/CVM1 Series CPU, select the RS-232C input port. Communication method switch: RS-232C RS-422 Section 2-3 I/O port selector switch Set to RS-232C. ...

Page 31

...

Page 32

The Direct Connection Function Direct Connection is a new function added to the Host Interface Unit. Its features are described below. Direct Connection When a Host Interface Unit is mounted to a PT, the bits and words of the ...

Page 33

Data Allocated in the PC The following bits and words of the PC memory area can be allocated. Area name Symbol y C-series PC CV-series Area DM Area I/S IR area CIO Area TC or Timer /Counter ...

Page 34

Example: Lamp 0 Bit: 010012 Character-string memory table 2 No. saved words: 3 words First word: DM0100  Notification of Display When the contents of a currently displayed numeral or character-string memory Elements table is changed or a touch switch ...

Page 35

First word (Word n): Set with the Support Tool when the screen is created Word Copy type status control bit n ...

Page 36

Touch Switches On and Off and 4-4 Editing Displayed Numerals and Char- acter Strings . Using the PT Status Control Area When control data is written to the PT Status Control Area, the PT responds as shown in the ...

Page 37

PT Status Control Area First word (Word n): Set with the Support Tool when the screen is created. without General Memory Word Copy type n ...

Page 38

Notify General Memory The touch switch notify bits can be allocated to the control general memory. Us- ing this memory has the following effects. The notify general memory is written to the PC simultaneously with the PT Sta- tus Notify ...

Page 39

SW4-2 sets the PT Status Control Area and PT Status Notify Area in the general memory. ON OFF PT Status Control Area First word (Word n): Set with the Support Tool when the screen is created. when General Memory Not ...

Page 40

PT processing PT power ON Initialize Write initial values to memory tables Read PT Status Control ...

Page 41

PT processing High Write to PT Status Notify Area Write bits Order of priority Write Numeral table entry Write character-string memory ...

Page 42

        ...

Page 43

... The following equipment and settings are used in the examples in this section: General memory: PT: NT600M-DT211 (EL display, touch panel version NT600M) PC: OMRON C200H Support Tool NT20M/NT2000M/NT600M Support Tool Version 4.0 & Direction Connection OMRON Set with the Tool Setting screen on the Support Tool. Refer to 4-1-3 Setting Direct Connection for details ...

Page 44

... Support Tool version NT20M, NT2000M, or NT600M. Tool Settings NTM model setting (PT model) Memory capacity setting (screen memory) Direct Connection (OFF, OMRON) Create Screen Create new file: select New File Edit existing file: select file to edit Section 4-1 ...

Page 45

Create New File Enter filename on completion. Setting Direct Connection Press the function key Information following data. PT Status Control Area (word allocation) PT Status Notify Area (word allocation) Numeral table (word allocation) Character-string memory table (word allocation) Reuse existing ...

Page 46

... Setting Direct Connection Set Direct Connection with the Support Tool before selecting a file set from the Main Menu of the Tool Setting screen. To select Direct Connection, set the Direct Connection item to either OMRON or ON (depending on the Support Tool version). Screen Selection Display ...

Page 47

NT20M/NT2000M/NT600M Support Tool Version 4.0 & Connecting to the Support Tool The following equipment and software is required to create screens with the Support Tool: Computer:PC/AT compatible computer. Software: Connecting cable: CV500-CN228 cable Refer to the NT-series Support ...

Page 48

NT600M 4-2 Switching Displayed Screens Description Write the screen number to the Screen Switch setting in the PT Status Control Area to switch the screen displayed on the PT. * Allocated start address: Word n (set with the Support Tool) ...

Page 49

Create a PC program to write the number of the displayed screen to the Important Points The displayed screen switches when the contents of the allocated word are changed. To re-specify the number of the currently specified screen, first ...

Page 50

When a program is created as in (3) above, the screen can also be switched from the PT using the Stand-alone functions (screen switch function) and it is not nec- essary to input the same screen number twice. The step ...

Page 51

DM I TIM TC or CNT The range of each memory area differs according to the PC type. Refer to Appendix B PC Memory Map for more details. Procedure 1, 2, 3... 1. Use the ...

Page 52

Set the initial values of the character-string memory table as shown below not necessary to allocate addresses. Character-string memory table Program Create a PC ladder program, as follows: 09000 Error Flag bit 09000 Error ...

Page 53

This is a convenient method to display changes in memory contents when moni- toring the PC memory. PT Numeral table entry #1 12345678 $' Character-string table 4 ." abcdef Allocate the words using the Support Tool. Restrictions Allocated Words The ...

Page 54

Stored as a double words Example: 12345678 Numbers can be handled in three different ways. The most-significant digit is processed differently according to the type of numeral display, as follows: Hexadecimal display: display of all digits identical to the contents ...

Page 55

Character codes 00 to 1FH are displayed as a normal space character. 00H is converted to 20H. Procedure 1, 2, 3... 1. Use the Support Tool to allocate the numeral and character-string memory 2. Create a PC program to write ...

Page 56

PC Program Create a PC ladder program, as follows: 1-second clock 25502 25506 (=) 00001 Operation PT operation when the created screen is displayed and the program is run is de- scribed below 3... 1. The contents of ...

Page 57

The range of each memory area differs according to the PC type. Refer to Appendix B PC Memory Map for more details. Refer to 4-4 Editing Displayed Numerals and Character Strings for information on saving numbers to allocated words. Note ...

Page 58

Another method of restoring the screen is to display a screen using the Screen Switch setting bit. Alarm Output (Bit 14) The Alarm Output bit turns on and off the ALM OUTPUT terminals at the rear of the PT. Alarm ...

Page 59

DM I TIM TC or CNT The range of each memory area differs according to the PC type. Refer to Appendix B PC Memory Map for more details. Procedure 1, 2, 3... 1. Use the ...

Page 60

PT Status Control bits are set as shown below when bit 09003 turns OFF Status Control bits are set as shown below when both bits 09002 and 4-7 Turning Lamps and Touch Switches On and Off Description ...

Page 61

Procedure 1, 2, 3... 1. Use the Support Tool to allocate the lamp and touch switch Control Bits to 2. Create a PC program to set the Control Bits on or off to light (flash) or extin- Reference The lamp ...

Page 62

Switch notification: PT Status Display Switch Flag New Screen number: Currently Displayed Screen      * Allocated start address: Word n (set with the Support Tool) Word status ...

Page 63

The PT Status Display Switch bit turns ON (1) in the PT Status Control Area when the screen display switches. It reverts to OFF (0) when the PC is notified of the screen switch. The current screen# can be read ...

Page 64

Allocated start address: Word n (set with the Support Tool) Word status Screen#: 000 to 127 (NT20M) Number Setting Strobe Flag Restrictions Allocated Words The ...

Page 65

Note The order in which the numbers are stored in the allocated words depends on the original specification of the Host Interface Unit NT20M-SMR01 or NT600M-SMR01-V & . Refer to 5-4 Modifying Programs for Conversion . Numbers can be handled ...

Page 66

Numeral table entry number 4: 0004 (words: 1) Screens Create a number setting screen with the Support Tool to input values into memory tables numbers 3 and 4 and transfer it to the PT. Numbers should be input as 4 ...

Page 67

Bit 12: Screen Switch Strobe Flag Bit 11: Number Setting Strobe Flag PT Operating Status (Bit 15) This bit is ON (1) when the Run mode OFF when the PT is not in ...

Page 68

PT Status Notify Area: 0110 Screens Not required. PC Program Create a PC ladder program, as follows: 11213 Low battery alarm bit Operation PT operation when the program is run is described below. If the low-batter notify bit (11213) is ...

Page 69

The range of each memory area differs according to the PC type. Refer to Appendix B PC Memory Map for more details. Procedure 1, 2, 3... 1. Use the Support Tool to allocate the touch switch notify bits to the ...

Page 70

PC Program Create the following ladder program. 1 scan ON 25315 06001 05001 Touch switch #10 notify bit 06000 05000 Operation PT operation when the created screen is displayed and the program is run is de- scribed below. Refer to ...

Page 71

&  %  &/  3  7   %    /& *   % &/    /   *   "++   /& *   "'(")     *  3   *   +   ...

Page 72

... It can be set in two ways, as follows: OFF: Direct Connection not used. Conventional Host Interface Unit specifica- OMRON or ON: Enables Direct Connection for the OMRON C Series and CV/ Refer to 2-3 Connection to an OMRON PC for information on compatible PCs. The “conventional” Host Interface Unit specification refers to a Host Interface ...

Page 73

Set the Direct Connection format of the data after conversion using “Direct 2. Select the file to be converted from the File Directory. 3. The following prompt is displayed: 4. Press the RETURN KEY to run ...

Page 74

Set the number of words allocated to the numeral table ( words), the start address, initialize/not initialize. Display method: Set if the numbers are displayed as a decimal or hexadecimal value. Other number-related settings remain unchanged after the ...

Page 75

The setting to initialize the memory table or not should remain unchan- ged. Start address (Word n): Set to DM0000, DM0256, DM1024, or DM2048. Word ...

Page 76

Modifying Programs for Conversion This section describes the method to modify a program created for a conven- tional Host Interface Unit (Direct Connection OFF) to use it for Direct Connec- tion important to understand the differences between ...

Page 77

Example 3 All control and notification uses bits instead of lamp and touch switch numbers, so that lamps and touch switches can all be handled by a single process and it is not necessary to change the processing to suit ...

Page 78

Modification and Settings 6 , page 76). Conventional format PT Number input 0 5-4-2 Program Modifications and Setting Areas If existing programs are re-used, ...

Page 79

Example: Allocation of lamp #64 to turn the lamp on when bit 000001 turns ON Conventional format 000001 000002 When bit 000001 turns ON an instruction lights lamp #64. The lamp turns off when bit 000002 turns ON. Modification and ...

Page 80

Example: To read numbers input with the PT number setting function to numeral Conventional format (always ON) 25313 HR1012 01000 25506 (=) HR0000 25506 (=) Bit 12 of DM0008 is the flag for data written from the PT. When this ...

Page 81

Example: Writing the value --1234567 to numeral table entry number 2 when bit Conventional format 00001 @MOV(21) @MOV(21) @MOV(21) If numeral table is allocated to memory, a negative number cannot be directly written the conventional format. Instruction ...

Page 82

&  %  & # %   /  &  %  #    , -   "  /& & /   % "   "  *  "#  ,   -   ...

Page 83

Errors Occurring when the Power is Turned ON Refer to the table below for the causes and remedies for errors occurring when the PT power is turned on. General source of error No Host Interface Unit Host Interface Unit ...

Page 84

Error Display Communication errors are displayed as follows: Error on Receive Error on Transmit General source of error Parity error Communication parameters set incorrectly. Overrun error Framing error Buffer overflow Noise caused data corruption during communica- tion. Timeout Cable connector ...

Page 85

Communication Specifications Item Communication EIA RS-232C standard Communication settings Start-stop synchronization Baud rate: 4800, 9600, 19200 bps Data bits: 7 Stop bits: 2 Parity: even Connectors 25-pin D-sub connector (female), Optical Fiber Cable compatible No. of units 1-to-1 Transmission distance ...

Page 86

... C20H t type C28H C40H C60H C120 0000 to 0063 C200H 0000 to 0255 C500 0000 to 0063 C1000H 0000 to 0255 C2000(H) OMRON CV/CVM1 Series Memory Map PC CIO Area 0000 to --- CV500 2555 2555 CVM1-CPU01-E 0000 to --- CV1000 2555 2555 CVM1-CPU11-E Note Range applicable to PT operation. ...

Page 87

... Prepare a connector cable to connect OMRON PC separated by more than 2 m when the supplied connector cable cannot be used. Connect the wires to the connectors in accordance with the connector specification for each unit. Parts Required Two connectors, two connector covers and one cable are required to make up a connecting cable. One connector and connector cover is supplied with each PT and PC unit ...

Page 88

Signal direction: Signal input and output is relative to the PC. Connector pin # p 1 Frame ground 2 Send data 3 Receive data 4 Request to send 5 Clear to send 7 Signal ground 14 Optical connector +5V (see ...

Page 89

Connector pin # p 1 Frame ground 2 Send data 3 Receive data 4 Request send 5 Clear to send 7 Signal ground 14 Optical connector +5V (see note 2) 15 Send signal element timing 2 (see note 1) 17 ...

Page 90

Connector pin # p 1 Frame ground 2 Send data 3 Receive data 4 Request to send 5 Clear to send 7 Signal ground Wiring Connections Connect the cable shielding wire to the connector cover and Pin 1 at both ...

Page 91

Connector pin # p Connector cover Frame ground 1 Frame ground 2 Send data 3 Receive data 4 Request to send 5 Clear to send 7 Signal ground 8 Carrier detected 14 Optical connector +5V 20 Data terminal ready Communication ...

Page 92

Communication port #1: 25-pin connector PT (Host Interface Unit) Abbrevi- ation RS-232C RS interface CS SG Communication port #2: 9-pin connector PT (Host Interface Unit) Abbrevi- ation RS-232C RS interface CS SG Connecting a ...

Page 93

Connector pin # p Connector cover Frame ground 2 Send data 3 Receive data 4 Request to send 5 Clear to send 9 Signal ground Wiring Connections Connect the cable shielding wire to the connector cover and Pin 1 at ...

Page 94

Wrap aluminum foil tape around the folded-back shielding wire. (1) (2) (3) ( (5) (6) Cable with Shielding Wire Not Connected 3... 1. Cut the cable to the required length. 2. Remove the ...

Page 95

Pre-solder each wire and connector terminal. 3. Solder each wire to the connector terminal. 4. Push the heat-shrink tube over the soldered joint and heat the tube to shrink it in place. Connector Cover Assembly Assemble the connector covers ...

Page 96

... A PT with a Host Interface Unit installed and an OMRON PC are connected with an RS-422 cable. RS-422 cables can connect between 15 m and 500 m apart. RS-422 connection permits a 1-to-N connection between the host computer and PC (that is, multiple PCs can be connected to a single computer). However PT-to-PC connection 1-to-1 basis only. ...

Page 97

... XZ7-10049 (25-pin to 9-pin cable more than 2 m long is required, refer to Appendix 3C RS-232C Connections for details on how to make one. RS-422 Cable OMRON does not provide RS-422 cables. Refer to this Appendix if an RS-422 cable is required. SYSMAC C Series PC, Host I/F connector CVM1/CV Series PC RS-232C, 25-pin ...

Page 98

Link Adaptors The Link Adaptor is a converter to connect different types of communication cables together. Set the switches as shown below when a Link Adaptor is used. Refer to the SYSMAC C-series Rack PCs SYS- MAC WAY - Host ...

Page 99

Wiring Connections The wiring of the RS-232C cables to connect the PT to the Link Adaptor and the PC to the Link Adaptor is described below. However, the PC connector specification depends on the type of PC. Refer to Appendix ...

Page 100

Wiring Connections The connection of two Link Adaptors with an RS-422 cable is shown below. Link Adaptor Abbrevi- ation RDB SG RS-422 interface SDB RDA FG SDA Connecting Units with an RS-422 Connector The connector specifications and wiring connections for ...

Page 101

Wiring Connections Link Adaptor Abbrevi- ation RDB SG RS-422 interface SDB RDA FG SDA Connecting Series Host Link Unit (Insulated) C Series Host Link Unit 25-pin Connector Specifications Applicable Host Link Unit: C500-LK201-V1 C120-LK202-V1 Electrical characteristics: Complies ...

Page 102

Connecting Series Host Link Unit CV Series Host Link Unit Connector Specifications Applicable Host Link Unit: CV500-LK201 (communication port #2) Electrical characteristics: Complies with EIA RS-422 Signal direction: Signal input and output is relative to the Host ...

Page 103

Connector pin # p Connector cover Frame ground 1 Send data A 2 Send data B 4 Request send 5 Clear to send 6 Receive data A 8 Receive data B Wiring Connections Short Pin 4 (RS) and Pin 5 ...

Page 104

Setting the Front Switches Set each switch with a flathead screwdriver until the displayed settings agree with the settings described on the previous page. LK201 RUN RCV ERROR SW1 0 0 SW3 5 2 Setting the Rear Switches C200H-LK201 CTS ...

Page 105

C200H-LK202 For types with an RS-422 connector. Termination resistance ON OFF C500(F), C1000(F) Rack-mounting Units C500-LK201-V1 C500-LK203 Setting the Rear Switches C500-LK201-V1 RS-422 I/O port RS-232C Internal Synchronization External Termination OFF resistance CTS External Termination resistance ON/OFF ...

Page 106

Setting the Rear Switches C500-LK203 supply OFF RS-422 I/O port RS-232C Synchronization Internal External Termination OFF resistance CTS External I/O port selector switch When connecting to the RS-232C connector, set to RS-232C. When connecting ...

Page 107

CPU-mounted Units C120-LK201-V1 C120-LK202-V1 Setting the Rear Switches SW1 SW2 SW3 Baud rate 19,200 bps 9,600 bps 4,800 bps DIP switch SW1: Unit #, parity, transfer code setting Unit # ...

Page 108

CV Series Rack-Mounting Units CV500-LK201 Setting the Front Switches Set the operating conditions with the PC System Setting functions when a CV Series Host Link Unit is connected to a PC. The PC System Settings can be made from the ...

Page 109

Connection to a CPU Set the operating conditions with the PC System Setting functions when connecting to a Mini H-type (C CV/CVM1 Series CPU. The PC System Settings can be made from the Peripheral Tool (FIT, etc system ...

Page 110

... Optical Fiber Cable Connections A PT with a Host Interface Unit installed and an OMRON PC are connected with a optical-fiber cable. The optical-fi- ber connection method is used in environments with a high level of noise and when the PT and PC are more than 15 m apart. Connection up to 500 m is possible but system configuration is restricted to 1-to-1 connections. ...

Page 111

... Host I/F connector, RS-232C, 25-pin Optical-fiber cable (APF/PCF/H-PCF) RS-232C-to-optical 25-pin converter, manufactured by OMRON PCF type, manufactured by OMRON When ordering, specify the cable length in the blank in the model number (  ). The following cable lengths are available 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190, 200, 250, 300, 350, 400, 450, and 500 ...

Page 112

Turn off both the PT and PC power supplies before connecting or disconnecting connectors. Connection to a Unit with an RS-232C or RS-422 connector The PT and PC are connected via Link Adaptors as shown in the diagram below. ...

Page 113

... If a cable longer than required, refer to Appendix C RS-232C Connections for information on making up cable. RS-422 Cable OMRON does not provide RS-422 cables. Prepare a connecting cable as described in Appendix D RS-422 Con- nections if required. Optical-fiber Cable The length of optical-fiber cable differs according to the type of cable and Link Amplifier, as shown in the following ...

Page 114

PC Switch Settings When the PT and PC are connected together, set the conditions at the PC Host Link Unit and the CPU as shown in the table below. The method of setting the conditions with the switches on each ...

Page 115

Setting the Rear Switches C200H-LK201 CTS selector switch External 0 V (ON) C200H-LK-202 For types with an RS-422 connector. Termination resistance ON OFF DIP Switch: 1-to-1/1-to-N setting supply setting Set ...

Page 116

C200H-LK-101-P For types with an optical-fiber connector. 1-to-1/1-to-N selector switch. Set to 1-to-N (OFF). 1-to-1 (ON) 1-to-N (OFF) Appendix E ...

Page 117

C500(F), C1000(F), Rack-mounting Types C500-LK201-V1 C500-LK101-(P)V1 C500-LK203 C500-LK103(-P) Setting the Rear Switches C500-LK201-V1 RS-422 I/O port RS-232C Internal Synchronization External Termination OFF resistance CTS External I/O port selector switch When connecting to the RS-232C connector, set to ...

Page 118

C500-LK101-(P) SW1 SW2 Baud rate 19,200 bps 9,600 bps 4,800 bps C500-LK203 supply OFF RS-422 I/O port RS-232C Synchronization Internal External ...

Page 119

C500-LK103(- SW1 SW2 Baud rate 19,200 bps 9,600 bps 4,800 bps DIP switch SW1: Unit # setting ...

Page 120

CPU-mounted Type C120-LK201-V1 C120-LK202-V1 C120-LK101-(P)V1 Setting the Rear Switches C120-LK201-V1, C120-LK202-V1 DIP switch SW1: Unit #, parity, transfer code setting SW1 Parity is fixed at Even Parity, Transfer Code is fixed at ASCII, 7 data bits, 2 stop bits SW2 ...

Page 121

C120-LK101-(P)V1 SW2 SW1 Baud rate 19,200 bps DIP switch SW1: Unit #, parity, transfer code setting Parity is fixed at Even Parity, Transfer Code is fixed at ...

Page 122

CV Series Backplane Mounted Type CV500-LK201 Setting the Front Switches Set the operating conditions with the PC System Setting functions when a CV Series Host Link Unit is connected to a PC. The PC System Settings can be made from ...

Page 123

Connection to a CPU Set the operating conditions with the PC System Setting functions when connecting to a Mini H-type (C CV/CVM1 Series CPU. The PC System Settings can be made from the Peripheral Tool (FIT, etc system ...

Page 124

Host Interface Unit PT Name Model Specifications NT20M-DT131 NT20M-DT121-V2 NT600M-DT122 NT600M-DT211 Host Link Unit Model C120-LK101-(P)V1 CPU-mounted type with optical-fiber cable connector C120-LK201-V1 CPU-mounted type with RS-232C connector C2120-LK202-V1 CPU-mounted type with RS-422 connector C200H-LK101-P Rack-mounting Unit with optical-fiber cable ...

Page 125

... XM2A-0901 DB-25P XM2S-2511 XM2S-0901 DB-C2-J9 Appendix F Comments Applicable Host Link Unit/CPU C120-LK201-V1 C200H-LK201 C500-LK201-V1 CV500-LK201 C20H/C28H/C40H/C60H CV500-LK201 CV500-CPU01 CV1000-CPU01 CVM1-CPU01 CVM1-CPU11 Specification Specification 25-pin, manufactured by OMRON 9-pin, manufactured by OMRON 25-pin, manufactured by JAE 25-pin, manufactured by OMRON 9-pin, manufactured by OMRON 25-pin, manufactured by JAE ...

Page 126

... XM2A-0901 DE-9P XM2S-0901 DE-C1-J6 Specification RS-232C-to-optical 25-pin converter, manufactured by OMRON PCF type, manufactured by OMRON When ordering, specify the cable length in the blank in the model number (  ). The following cable lengths are available 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190, 200, 250, 300, 350, 400, 450, and 500. ...

Page 127

A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. V015-E1-1 The following table outlines the changes made to the manual during each revision. Page numbers refer to the ...

Page 128

... For US technical support or other inquiries: 800.556.6766 OMRON CANADA, INC. 885 Milner Avenue 1 5 Toronto, Ontario 416.286.6465 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca V015-E1-1 8 ©2002 OMRON ELECTRONICS LLC Printed in the U.S.A. Specifications subject to change without notice. ...