CV500CN228 Omron, CV500CN228 Datasheet - Page 37

no-image

CV500CN228

Manufacturer Part Number
CV500CN228
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN228

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
PT Status Control Area
without General Memory
3-3-2 PT Status Notify Area
Currently Displayed Screen
Content Upgrade Memory
Table
PT Status
Word
n
n + 1
n + 2
n + 3
to
n + 9
Word
n + 1
n + 2
n + 3
n
15 14 13 12 11 10 9
15 14 13 12 11 10 9
Copy type
0
PT status control bit
0
PT status
First word (Word n): Set with the Support Tool when the screen is created.
The PT Status Status Notify Area is set by choosing Direct or Direct Specify In-
formation under the Expansion Function from the Screen List on the Support
Tool.
Any changes in PT status are written to the PC PT Status Notify Area.
The PT Status Notify Area is configured as ten consecutive words, as shown in
the diagram below.
First word (Word n): Set with the Support Tool when the screen is created.
The screen number of the screen displayed on the PT is written to this word. Si-
multaneously, the PT Status Screen Switch Strobe Flag is set ON (1). After the
PC is notified, this flag reverts to OFF (0). Checking the status of this flag pro-
vides a simple method of checking if the PT display has switched.
The number of the numeral table is written to this word when the numeral table
contents change due to PT switch operation. The input value appears in the
word allocated for the appropriate numeral table. As the number of the numeral
table is written, the PT Status Number Setting Strobe Flag is simultaneously set
ON (1). After the PC is notified, this flag reverts to OFF (0). Checking the status
of this flag provides a simple method of checking if a number has been input from
the PT.
The bits shown in the following table are turned ON or OFF in response to the PT
operating status and battery level.
15
13
Numeral table entry number (3-digit BCD)
Bit
Word
n+ 2
Copy destination memory table#
(3-digit BCD)Copy type
Screen# (4-digit BCD)
Copy source memory table# (3-digit BCD)
Screen# (4-digit BCD)
PT operating status
Battery
8
15 14 13 12
Notified item
8
7
7
6
0
0
6
5
0
5
4
4
3
11
3
2
0
10
Run
Low
2
0
1
0
1
9
0 Bit
0
0 Bit
1 (ON)
8
0
Currently displayed screen
Content upgrade memory table
PT status
Notify general memory
(7 words)
Bit
Bit 12: Screen Switch Strobe Flag
Bit 11: Number Setting Strobe Flag
Screen switch setting
Copy memory
table setting
PT status control bits
Stop
Normal
0 (OFF)
Section 3-3