Watt Meter

10760

Manufacturer Part Number10760
DescriptionWatt Meter
ManufacturerSimpson
10760 datasheets
 


Specifications of 10760

Meter FunctionWattMeter Range0W To 750W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-750 WEquipment TypeWattage Meter
Range0 - 750Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Page 12/68

Download datasheet (7Mb)Embed
PrevNext
A
8
Specifications for F35 Frequency Meters
DISPLAY
Type
7-segment, red LED
Height
0.56" (14.2mm)
Overrange indication
Most significant digit = "1"; other digits
blank
POWER REQUIREMENTS
AC Voltages
120 or 220VAC, ±10% 50/60Hz
Power Consumption
2.5VA min./4VA max.
ACCURACY @25°C
200 Hz:
±0.2% of input ±0.2 Hz
2 KHz:
±0.2% of input ± 2Hz
INPUT LEVEL
500mV to 750V RMS at 1.0MW imped-
ance OR 5V to 24V Square Wave (DC
offset 2V maximum)
Resolution:
200Hz = 0.1Hz
2kHz =1Hz
ENVIRONMENTAL
Operating Temperature
0 to 55°C
-10 to 60°C
Storage Temperature
Relative Humidity
0 to 85% non-condensing @ 40°C
Temperature Coefficient
(±0.05% of input ± 0.5 count)/°C
Warm-up Time
Less than 15 minutes
Response Time
Less than 3 seconds
CONVERSION
Technique
Frequency-to-voltage
Rate
3 samples per second, nominal
ACCURACY @ 25°C
F35 ACA
±1% of reading ± 5 counts (45Hz - 1 kHz)
F45 ACA
±0.5% of reading ± 35 counts (45Hz - 1kHz)
F35 ACV
±0.1% of reading ± 5 counts (45Hz - 1kHz)
F45 ACV
±0.5% of reading ± 35 counts (45Hz - 1kHz)
F35 DCA & DC Process
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz - 1 kHz)
F45 DCA
±0.05% of reading ± 1 count
2A ± 5 counts 5A ± 5 counts
F35 DCV
±0.1% of reading ± 1 count 750 ± 2 counts
F45 DCV & DC Process
±0.02% of reading ± 1 count 750 ± 2 counts
F35 Frequency
200 Hz: ±0.2% of input ± 0.2Hz
2kHz: ±0.2% of input ± 2Hz
Inputs
DC Current
DC Process
Range Resolution Voltage
Max Input
Input
Drop
(Unfused)
Range
200 uA
4-20mA
1 uA
0.2V
100mA
2 mA
Range Resolution
Input
Maximum
20 mA
Impedance
Input
200 mA
1-5 DCV
10mV
10 M
100 V
2 A
0-10 DCV
10mV
10 M
100 V
Specifications for F45 Temperature Meters
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Warm-up Time
INPUTS
Thermocouple
RTD
Millivolt
Cold Junction Compensation
Error
Input Impedance
Lead Resistance Effect
Conversion Rate
Open Thermocouple Detection
AC/AC TRMS Voltage
Resolution Voltage
Maximum
Input
Drop
Overload
Range Resolution Impedance Overload
10nA
200mV
20mA
200 mV
10uV
100nA
200mV
20mA
2 V
100uV
1uA
200mV
100mA
20 V
1mV
10uA
200mV
500mA
200 V
10mV
100uA
200mV
2.2A
750 V
100mV
DC Voltage
Input
Input
Maximum
Range Resolution Impedance Overload
200 mV
10uA
>100M
50V
2 V
100uA
10M
100V
20 V
1mV
10M
100V
200 V
10mV
10M
250V
750 V
100mV
1M
750V
7-segment, red LED
0.56" (14.2mm)
Jumper-selectable 2-position (correspon-
ding to resolution desired)
Most significant digit = "1"; other digits blank
Automatic, with "-" indication,
"+" indication implied
120 or 220 ACV, ±10% 50/60Hz
9-32 DCV, ±1%
3VA
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
Less than 20 minutes
J, K, E, T, R, and S
Platinum 100 (.00385 alpha), 2, 3 or 4 wire
±84mV reading of uncompensated mV
0.1°C/°C
10MW(typical)
4.0µV/100W
2-1/2 times per second
-1 on display, -40nA bias on thermocouple
AC/AC TRMS Current
Input
Maximum
Input
Voltage
Range
Resolution
Drop
>100M
50V
200 uA
10nA
200mV
10M
100V
2 mA
100nA
200mV
10M
100V
20 mA
1uA
200mV
10M
250V
200 mA
10uA
200mV
1M
750V
2 A
100uA
200mV
5 A
1mA
200mV
Maximum
Overload
20mA
20mA
100mA
500mA
2.2A
2.2A