FLOW CONTROL REGULATOR, BANJO, 4MM

7010 04 19

Manufacturer Part Number
7010 04 19
Description
FLOW CONTROL REGULATOR, BANJO, 4MM
Manufacturer
LEGRIS
Datasheet

Specifications of 7010 04 19

Operating Pressure Psi Max
145psi
Operating Temperature Range
0°C To +70°C
Connection Size
4mm
Operating Temperature Max
70°C
Operating Temperature Min
0°C
Svhc
No SVHC (15-Dec-2010)
Operating Pressure Max
145psi
Rohs Compliant
NA
Valve Type
Flow Regulator
Lead Free Status / RoHS Status
na
non-return valves
Legris non-return valves allow air to pass in one direction
whilst blocking flow in the other direction. The V ring
technology ensure positive sealing, even when the fitting
is submitted to vibration. These fittings may be mounted
upstream of the circuit.
Their extreme compactness and light weight make them
suitable as a safety item in compressed air circuits.
pneumatic sensor fittings
Legris sensor fittings detect pressure drop
and are generally used to detect the end-of-travel
of a cylinder. They produce an end-of-stroke signal,
pneumatic or electric, when the exhaust back pressure
in the cylinder disappears.
They can be mounted on the cylinder or on the control
valve.
symbols of Legris pneumatic function fittings
regulating
air flow
controlling
air circulation
controlling
and
controlling
the passage of fluid in one direction
and non-return in the other
exhausting
and
regulating
controlling
diaphragm
non-return
to control
system
in-line version
(model 7996)
valve
pneumatic circuit supply
air flow
diaphragm
piston
A
diaphragm
non-return
(models 7984-7985)
supply version
B
P’ :
P
P1 :
S : output signal
C
:
exhaust pressure
system pressure
supply pressure
for sensor
specifications
suitable fluid : compressed air
working pressure : 1 to 10 bar
working temperature : 0° to + 70°C
specifications :
suitable fluid : compressed air
working temperature : -15° to + 60°C
working pressure : 3-8 bar
breaking pressure : 0-6 bar
response time : 3m.s.
diaphragm
non-return
detecting
pressure drop
regulating
pressure by stabilizing at a
required value
reducing
pressure supply
progressive
pressurising of circuits
isolate a circuit
without venting the whole installation
(models 7994-7995)
exhaust version
to control
valve
diaphragm
piston
"safety"
"safety"