Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CQM1-CQM1H Comparison
DM area
EM area
Memory Cassette
(EEPROM or flash
memory)
Trace memory
Item
CQM1H-
CPU51/61:
6,656 words
CQM1H-
CPU11/21:
3,584 words
Read/write
Read-only
Controller Link
DM parameter
area
Routing table
area
Serial Commu-
nications Board
Error history
area
PC Setup
6,144 words
Mounted from the front of the CPU Unit. Memory Cassettes are used to store and read the
user’s program, DM (read-only data and PC Setup), and expansion instruction information (as
one block of data).
It is possible to set the CPU Unit so that when power is turned ON, data stored in the Memory
Cassette (user’s program, DM, expansion instruction information) is automatically transferred,
in one block, to the CPU Unit (auto-boot). Two-way transfer, and comparison of data between
the CPU Unit and Memory Cassette is possible using AR area settings.
In addition to 4-Kword and 8-Kword EEPROM
Memory Cassettes, 15.2-Kword flash memory
Memory Cassettes are also available.
1, 024 words (trace comparison data:
12 points, 3 words)
DM area data is accessed
(read/write) in word (16-bit)
units. Word values are
retained when the power is
turned OFF or the mode is
changed.
CQM1H-CPU51/61:
DM 0000 to DM 6143
(6,144 words)
CQM1H-CPU21/11:
DM 0000 to DM 3071
(3,072 words)
Can be written by program.
DM 6144 to DM 6568
(425 words)
Cannot be written by
program.
CQM1H-CPU51/61:
DM 6400 to DM 6409
(11 words)
CQM1H-CPU11/21: None
CQM1H-CPU51/61:
DM 6450 to DM 6499
(50 words)
CQM1H-CPU11/21: None
CQM1H-CPU51/61:
DM 6550 to DM 6559
(10 words)
CQM1H-CPU11/21: None
DM 6569 to DM 6599
(31 words)
DM 6600 to DM 6655
(56 words)
EM area data can be read or
written in word (16-bit) units.
Contents are retained when
the power is turned OFF or
the mode is changed. Acces-
sible using instructions from
the program or
Programming Devices.
Read/write words:
EM 0000 to EM 6143
(6,144 words)
CQM1H
CQM1-
CPU4@-EV1:
6,656 words
CQM1-
CPU11/21-
EV1: 1,536
words
Read/write
Read-only
None
None
None
Error history
area
PC Setup
None
4-Kword and 8-Kword EEPROM Memory
Cassettes are available.
CQM1-CPU4@-EV1: 1,024 words (trace
comparison data: 12 points, 3 words)
DM area data is accessed
(read/write) in word (16-bit)
units only. Word values are
retained when the power is
turned OFF or the mode is
changed.
CQM1-
CPU4@-EV1: DM 0000 to
DM 6143 (6,144 words)
CQM1-CPU11/21-EV1:
DM 0000 to DM 1023
(1,024 words)
Can be written by program.
DM 6144 to DM 6568
(425 words)
Cannot be written by pro-
gram.
---
---
---
DM 6569 to DM 6599
(31 words)
DM 6600 to DM 6655
(56 words)
---
CQM1
Section 1-5
39