C48CB003 Red Lion Controls, C48CB003 Datasheet - Page 4

no-image

C48CB003

Manufacturer Part Number
C48CB003
Description
C48C (3P,R,SNK,RLY)
Manufacturer
Red Lion Controls
Type
Counterr
Datasheet

Specifications of C48CB003

Rohs Compliant
YES
Connection Type
Screw
Cut Out, Panel
1/16 DIN
Digit Height
0.3
Dimensions
4.17"L×1.95"W×1.95"H
Display Digit Height
0.3" (Main), 0.2" (Secondary)
Display Type
LCD
Function
Counter
Material, Casing
Plastic
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0.00001 to 9.99999
Special Features
programmable
Voltage, Supply
85 to 250 VAC
Sealing
NEMA 4X/IP65
Power Requirements
85 to 250 VAC
Operating Temperature
0 to +50°C
Panel Cutout
1.77" × 1.77" (1⁄16 DIN)
Lead Free Status / Rohs Status
RoHS Compliant part
USER INTERFACE/PROGRAMMING MODES
keypad. To enter the programming menu, the " key is pushed and held for 2
seconds. Within the programming menu, the " key is used to sequence through
the list of programming parameters.
Program Security/Operator Accessible Values
(programmed for Program Disable), and the Accessible Value parameters
provide various levels of security against unauthorized programming changes.
The accessible values parameters provide individual access or locking of each
value.
Protected Value Menu
timed output values without having them viewable or changeable from the main
display. To enter the protected menu, the
programmed code value is entered.
Programming Numeric Data Values
Pressing the " key will sequence the secondary display through the available
preset, prescaler and Batch/Total count values.
the $ or # key will allow changing of the value. If the data entry method has
been set to “digit entry”, pressing the $ key multiple times will select other
digits. Pressing the # key will increment the selected digit. If the data entry
method is set to “Auto scrolling”, the data value can be changed by pressing and
holding the # or $ keys to change one or all digits of the display.The data
value will be entered when the " key is pushed, or the old value will be
retained if no key activity is detected for 10 seconds.
The operating modes of the C48C are programmed using the front panel
The Program Disable DIP switch, programmable code value, User Input
The Protected Value Menu allows access to selected presets, prescaler and
The Presets may be accessible when the unit is in its operating mode.
To change a data value it must be visible on the secondary display. Pressing
Ac PSc
dEc Pt
Cnt In
OPEr 1
C2 ASn
OPEr 2
Ac PrS
Ac Out
OutP. u P
USr F1
PScALr
PrESEt
PltrAC
OutrES
OutPut
rEVOut
rEVAnu
USrIn1
USrIn2
USrInb
ScroLL
SErSEt
SErAdr
SErAbr
PrnOPt
PrnrSt
PScOAt
PScLEn
FAcSEt
EntrY
CodE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Digit or Auto Scrolling Data Entry Mode
Accessibility of Prescaler Value
Prescaler Value
Decimal Point Position
Count Input Modes
Counter 1 Operating Mode
Counter 2 Assignment (C48CB only)
Counter 2 Operating Mode (C48CB only)
Accessibility of Preset Values
Preset 1, 2, and 3 Values
P1 Track P2 (not available on C48CS)
Accessibility of Output Time Values
Output Resolution
Output 1, 2, and 3 Time Values
Reverse Output/Relay Logic
Reverse Output Annunciator Logic
Power Up Output State
User Input 1
User Input 2 (Not available on Batch Relay Models)
User Input b
User F1 Key
Programming/Protected Parameter menu Code
Scroll Display
Serial Baud Rate & Parity Settings
Serial Unit Address
Abbreviate Serial Mnemonics
Print Options
Print & Reset Count Value
Prescaler Output Pulse (C48CP only)
Prescaler Output Pulse Length {width} (C48CP only)
Load Factory Default Settings
PROGRAMMING MENU
"
key is pressed and held, and a
(RS485 option only)
4
Count Input Modes -
allows Input B to be used as a User Input with the same programmable
functions as the dedicated User Inputs.
* These are the only count input modes available on the Prescaler Output
Programmable Operating Modes -
tables, 01, 02, and 03, refer to Outputs 1,2, and 3 respectively.
This parameter controls the count/control function of Inputs A and B. It also
Model.
These modes determine the operational characteristics of the counter. In the
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
C1-USr
C2-USr
Ad-Sub
qUAd 1
qUAd 2
qUAd 4
C1-Ud
C2-Ud
Ad-Ad
MODE
- Manual Reset to Zero, Latched Output
- Manual Reset to Zero, Timed Output
- Manual Reset to Preset, Latched Output
- Manual Reset to Preset, Timed Output
- Auto Reset to Zero, Timed Output
- Auto Reset to Preset, Timed Output
- Auto Reset to Zero at Timed Output End
- Auto Reset to Preset at Timed Output End
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DUAL PRESET AND BATCH COUNTER 1 OPERATING MODES
Manual Reset to Zero, Latched Outputs
Manual Reset to Zero, 01 Timed, 02 Latched
Manual Reset to Zero, 01 and 02 Timed
Manual Reset to Zero, 01 off at 02, 02 Latched
Manual Reset to Zero, 01 off at 02, 02 Timed
Manual Reset to Preset 2, Latched Outputs
Manual Reset to Preset 2, 01 Timed, 02 Latched
Manual Reset to Preset 2, 01 and 02 Timed
Manual Reset to Preset 2, 01 off at 02, 02 Latched
Manual Reset to Preset 2, 01 off at 02, 02 Timed
Auto Reset to Zero, 01 and 02 Timed
Auto Reset to Zero, 01 off at 02, 02 Timed
Auto Reset to Preset 2, 01 and 02 Timed
Auto Reset to Preset 2, 01 off at 02, 02 Timed
Auto Reset to Zero at 02 End, 01 and 02 Timed
Auto Reset to Zero at 02 End, 01 off at 02, 02 Timed
Auto Reset to Preset 2 at 02 End, 01 and 02 Timed
Auto Reset to Preset 2 at 02 End, 01 off at 02, 02 Timed
Manual Reset to Zero, 03 Latched
Manual Reset to Zero, 03 Timed
Manual Reset to Preset 3, 03 Latched
Manual Reset to Preset 3, 03 Timed
Auto Reset to Zero, 03 Timed
Auto Reset to Zero at 03 Timed Output End
Auto Reset to Preset 3, 03 Timed
Auto Reset to Preset 3 at 03 Timed Output End
COUNTER 2 OPERATING MODES (C48CB Only)
SINGLE PRESET OPERATING MODES
Cnt In
Count (X2)
Count (X2)
Add Count
Add Count
INPUT A
Count
Count
Quad X1 Inputs
Quad X2 Inputs
Quad X4 Inputs
OPEr
Up/Dn Control
Subtract Count
Up/Dn Control
User Input
Add Count
User Input
INPUT B
*
*