66321B AGILENT TECHNOLOGIES, 66321B Datasheet

POWER SUPPLY, DC, 15V, 125W

66321B

Manufacturer Part Number
66321B
Description
POWER SUPPLY, DC, 15V, 125W
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 66321B

Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
15V
Output Current
3A
Power Rating
125W
Input Voltage
-25V DC To 25V DC
Length
435mm
Width
212.8mm
Height
88.1mm
Weight
20lb
Lead Free Status / RoHS Status
na
Application Specific DC Power Supplies tailored solutions for specific needs
Overcome Battery Powered
Device Testing Challenges
Digital communications devices
and digital battery powered devices
present a unique testing challenge:
they draw rapid pulses of current.
By offering superior transient
performance, unmatched in the
marketplace, the Agilent Mobile
Communications DC Sources
dramatically reduce the transient
voltage drop due to pulse loading
characteristics of digital communi-
cations devices. The Agilent Mobile
Communications DC Sources enable
you to maximize test throughput by
minimizing test interruption due to
false trigger of device low voltage
shutdown.
Dynamic Measurement Capabilities
The Agilent Mobile Communications
DC Sources offer a built-in advanced
measurement system to accurately
measure battery current drains
when the device operates in differ-
ent modes (such as talk mode, active
mode, standby mode, and off/sleep
mode). Measurements made during
these modes are critical for ensuring
that your devices are operating
properly and that you are getting
the most out of the battery.
Simulate both Main Battery and Charger
Single output models are recom-
mended when you need to provide
power as a replacement to your
66319B/D, 66321B/D
Mobile Communications DC Sources
40-100 W
Ideal for testing wireless and battery powered devices
Several times improvement in measurement throughput over general purpose DC sources
Superior output transient performance with short or long load leads (up to 6 meters)
Dynamic measurement system for accurate battery current drain measurement
New easy-to-use Graphical User Interface and analysis tools for bench top use
Specifications
(at 0
otherwise specified)
Number of outputs
GPIB
Output ratings
Voltage
Current
Peak current for up to 7 ms
Programming accuracy
at 25°C ±5°C (% of setting plus fixed)
Voltage
+Current
Ripple and Noise (20 Hz to 20 MHz)
Voltage
Current
DC measurement accuracy
Voltage
+20 mA to + rated current 0.2%+
-20 mA to - rated current
-3 A to + 5 A
-1 A to + 1 A
-20 mA to + 20 mA range 0.1%+
Dynamic measurement system
Buffer size
Sampling interval
Transient response time
Transient voltage dip
(typical with up to 15 feet
22 AWG wiring)
Programmable output resistance
Range
Programming accuracy
Resolution
˚
to 55
˚
C unless
peak-to-peak
81
0.05%+
0.05%+
0.03%+
0.2%+
0.2%
0.1%
rms
rms
More detailed specifications at www.agilent.com/find/66300
66309B/D 66311B
2
Yes
0 to 15 V
0 to 3 A
5 A
10 mV
1.33 mA
1 mV
6 mV
2 mA
5 mV
0.5 mA
1.1 mA
2.5 µA
4096 points 4096 points 4096 points 4096 points 4096 points 4096 points
15 µs -
31,200 s
<35 µs
70 mV
—-
3
2
1
Yes
0 to 15 V
0 to 3 A
5 A
10 mV
1.33 mA
1 mV
6 mV
2 mA
5 mV
0.5 mA
1.1 mA
2.5 µA
15 µs -
31,200 s
<35 µs
70 mV
2
3
66319B/D 66321B/D 66332A
2
Yes
0 to 15 V
0 to 3 A
5 A
10 mV
1.33 mA
1 mV
6 mV
2 mA
5 mV
0.5 mA
0.2 mA
2.5 µA
15 µs -
31,200 s
<20 µs
40 mV
-40 mΩ to
+1 Ω
0.5% +
2 mΩ
1 mΩ
3
2
1
Yes
0 to 15 V
0 to 3 A
5 A
10 mV
1.33 mA
1 mV
6 mV
2 mA
5 mV
0.5 mA
0.2 mA
2.5 µA
15 µs -
31,200 s
<20 µs
40 mV
-40 mΩ to —
+1 Ω
0.5% +
2 mΩ
1 mΩ
2
1
Yes
0 to 20 V
0 to 5 A
5 A
10 mV
2 mA
0.3 mV
3 mV
2 mA
3 mV
0.5 mA
1.1 mA
2.5 µA
15 µs -
31,200 s
<100 µs
500 mV
4
66332A-
J01
Special Order
Option
1
Yes
0 to 30 V
0 to 3.3 A
3.3 A
15 mV
2 mA
0.5 mV
5 mV
2 mA
5 mV
0.5 mA
1.1 mA
2.5 µA
15 µs -
31,200 s
<100 µs
650 mV
4

Related parts for 66321B

66321B Summary of contents

Page 1

... Transient voltage dip (typical with feet 22 AWG wiring) Programmable output resistance Range —- — Programming accuracy — — Resolution — — More detailed specifications at www.agilent.com/find/66300 81 66319B/D 66321B/D 66332A 66332A- J01 Special Order Option Yes Yes Yes Yes ...

Page 2

... Performs Like a Battery With their battery emulation features, the Agilent 66319B/D and 66321B/D allow you to test your devices under the same power conditions that exist in actual use. Emulating the battery is key when characterizing battery operating life and detecting early product failures ...

Page 3

... For 66332A: 3.5 A, 250 W. Regulatory Compliance Complies with EMC directive 89/336/EEC (ISM 1B). Warranty Period One year Size For 66309B/D, 66311B, 66319B/D, 66321B/D: 212 88 435 17.13 in). For 66332A: 425 88 364 (16 3 14.3 in). Weight For 66309B/D, 66311B, 66319B/D, 66321B/D: 9.07 kg (20 lb) net, 11.1 kg (24 ...

Page 4

... Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service manual * Support rails required Agilent Models: 66309B/D, 66311B, 66319B/D, 66321B/D More detailed specifications at www.agilent.com/find/66300 84 Accessories p/n 1494-0060 Rack Slide Kit (66332A only) E3663AC Support rails for ...

Page 5

Application Specific DC Power Supplies tailored solutions for specific needs Terminal Strip Detail Mobile Communications DC Sources 40-100 W (Continued) Agilent Models: 666332A Output 2 & Screw Size: M35 x 0.6 100mm 3.93" 425.4mm 16.75" ...

Page 6

Application Specific DC Power Supplies tailored solutions for specific needs 3 Simplify test and analysis in R& the repair bench With the Agilent 14565B Device Characterization Software, testing, analyzing, and troubleshooting wireless and battery powered devices is made ...

Page 7

... Device Characterization Software Upgrade (provides upgrade from 14565A to 14565B Software) Note: Battery Drain Analysis means Data Logging and CCDF measurements. These capabilities require models 66319B, 66319D, 66321B or 66321D with version A.03.00 firmware or higher and 14565B or 14565A software version 3.01 or higher. ...