HDL26020 SQUARE D, HDL26020 Datasheet - Page 30

CIRCUIT BREAKER, THERMAL MAG, 2P, 20A

HDL26020

Manufacturer Part Number
HDL26020
Description
CIRCUIT BREAKER, THERMAL MAG, 2P, 20A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL26020

Actuator Style
Toggle
No. Of Poles
2
Current Rating
20A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
30
PowerPact
Section 2—Mounting and Connections
J-Frame Long Lug Shield
J-Frame Short Lug Shield
H-Frame Short Lug Shield
06/2010
®
H- and J-Frame Circuit Breakers
Compression Lugs
Both copper and aluminum compression lug kits are available for the H-frame and J-frame circuit
breakers. Each kit contains required insulators and all mounting hardware.
Table 36:
Terminal Shields
Table 37:
1
2
Lug
Type
Aluminum
Copper
Mechanical Lugs
Power
Distribution
Connectors and
Compression
Lugs
Phase Barriers
Used With
Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals.
J-frame terminal shield is not compatible with the YA250J35 compression terminal.
Compression Lug Kits
Terminal Shields and Phase Barriers
Short Lug
Shield
H-Frame
Long Lug
Shield
J-Frame
Long Lug
Shield
1
Frame
H-Frame
J-Frame
H-Frame
J-Frame
Frame
H-Frame 60 A
H-Frame 150 A
J-Frame
Compatible with:
PDC
PDC6HD6
PDC3HD2
PDC6JD4
PDC3JD2
Description
Kit Number Wire Range
YA060HD
YA150HD
YA150JD
YA250J35
CYA060HD
CYA150HD
CYA150JD
CYA250J3
Compression Lugs
Aluminum
YA060HD
YA150HD
YA150JD
2
Max. Wire Size
3 AWG
3/0 AWG
350 kcmil
6–2 AWG Cu or Al
(16–35 mm
1/0–4/0 AWG Cu or Al
(50–95 mm
1–3/0 AWG Cu or Al
(50–95 mm
3/0 AWG–350 kcmil Cu or Al
(95–185 mm
6–1/0 AWG Cu
(16–50 mm
4–2/0 AWG Cu
(25–70 mm
4–2/0 AWG Cu
(25–70 mm
2/0 AWG–300 kcmil Cu
(70–185 mm
Copper
CYA060HD
CYA150HD
CYA150JD
CYA250J3
2
2
2
2
2
2
)
)
)
)
)
)
2
2
)
)
S37446
S37447
S37448
S37449
S37450
29329
Cat. No.
2
2
1
1
1
1
1
6
Qty
Per
Kit
Ampere
Rating
d 60 A
d 150 A
d 200 A
d 250 A
d 60 A
d 150 A
d 150 A
d 250 A
0.50
0.50
0.24
2.24
1.68
3.13
© 2004–2010 Schneider Electric
w/Mechanical
Molded Case
Dimension B (in.)
Extremity
Lugs
Per Kit
3
3
3
3
3
3
3
3
Lugs
extension past end
of
Phase barrier or
“B” See Table
terminal shield
of circuit breaker
“B” See Table
All Rights Reserved
Mounting
Screw Torque
80–90 lb-in
(9.0–10.2 N•m)
80–90 lb-in
(9.0–10.2 N•m)
130–140 lb-in
(14.7–15.8 N•m)
130–140 lb-in
(14.7–15.8 N•m)
80–90 lb-in
(9.0–10.2 N•m)
80–90 lb-in
(9.0–10.2 N•m)
130–140 lb-in
(14.7–15.8 N•m)
130–140 lb-in
(14.7–15.8 N•m)

Related parts for HDL26020