Summary of the Analog Input Slave Units
Hold Flags (Output)
318
Note
Hold Flags are used with the peak/bottom hold and top/valley hold functions.
The Hold Flags are used to control the hold execution timing from the Master
Unit and are allocated in the Master Unit using the following data format (1
word (2 bytes)).
The meaning for each bit is as described below.
After a Hold Flag is turned ON at the Master Unit, there is a transmission time
delay for notification of this to the unit.
15
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
Bit
+0
+1
0
1
2
3
Bit 7
Abbreviation
0
0
Bit 7
0
0
HD0
HD1
HD2
HD3
Bit 6
0
0
+1
Bit 6
0
0
Bit 5
Analog Data 1 for Input CH0
Analog Data 1 for Input CH1
Analog Data 1 for Input CH2
Analog Data 1 for Input CH3
Hold Flag for
Input CH0
Hold Flag for
Input CH1
Hold Flag for
Input CH2
Hold Flag for
Input CH3
0
0
Bit 5
0
0
Name
Bit 4
0
0
8
Bit 4
0
0
V_ST3 V_ST2 V_ST1 V_ST0 Lower byte
T_ST3 T_ST2 T_ST1 T_ST0 Upper byte
7
Bit 3
The hold function is performed for Analog
Input CH0 while this flag is ON. The hold
function stops and the last value is held
when the flag goes OFF.
The hold function is performed for Analog
Input CH1 while this flag is ON. The hold
function stops and the last value is held
when the flag goes OFF.
The hold function is performed for Analog
Input CH2 while this flag is ON. The hold
function stops and the last value is held
when the flag goes OFF.
The hold function is performed for Analog
Input CH3 while this flag is ON. The hold
function stops and the last value is held
when the flag goes OFF.
Bit 3
HD3
0
Bit 2
Bit 2
HD2
0
+0
Bit 1
Details
Bit 1
HD1
0
Bit 0
Bit 0
HD0
Section 6-2
0
Lower byte
Upper byte
Lower byte
Upper byte
Lower byte
Upper byte
Lower byte
Upper byte
0
Lower
Upper
byte
byte