Specifications of XPSAC3421P

Contact Current Max
60mA
Contact Voltage Ac Nom
115V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Wiring diagrams
(1) Instantaneous opening safety outputs (stop category 0).
(2) Time delay opening safety outputs (stop category 1).
ESC = External start conditions.
Linked input
S11-S12
Guard (channel 1)
S21-S22
Guard (channel 2)
S31-S32
Guard open
S13-S14
Time delay interrupt
Y39-Y40
N.O. output
03-04/13-14/23-24
N.O. output
37-38/47-48/57-58
Signalling output
Y74
Signalling output
Y84
1
2
3
4
Principle:
page 2/178
XPSAV
Monitoring of a movable guard associated with 2 switches
Automatic start (diagram shown for guard closed)
Functional diagram
LED details
5 6 7 8
Power-up
closed
Guard
Characteristics:
page 2/178
closed
Guard
Logic
channel 1
Logic
channel 2
9
10
11
(continued)
Guard
open
Start
1 S12 input status.
2 S22 input status.
3 S32 input status.
4 S34 input status.
5 S14 input status.
6 Y40 input status (time delay stop).
7 K1/K2 status (N.O. instantaneous opening safety outputs).
8 K3/K4 status (time delay opening safety outputs).
9 Supply voltage A1-A2.
10 Fault.
11 Configuration mode
closed
Guard
Guard
closed
Output 1
Output 1
Output 2
Output 2
Time delay
stop
Tv = 0…300 s
Safety automation system solutions
Preventa™ safety relay modules type XPSAV
For Emergency stop and switch monitoring
References:
page 2/180
Guard
open
Start
Guard
closed
Time delay
interrupted
Guard
open
Wiring Diagrams:
page 2/181
To PLC
Dimensions:
page 2/260
2/183
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9