XPSAC3421P SQUARE D, XPSAC3421P Datasheet - Page 249

SAFETY RELAY 300V 2.5A PREVENTA

XPSAC3421P

Manufacturer Part Number
XPSAC3421P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAC3421P

Contact Current Max
60mA
Contact Voltage Ac Nom
115V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
1
2
3
4
5
6
7
8
9
Operating principle
Principle:
page 2/248
2/248
Characteristics:
page 2/249
Safety automation system solutions
Preventa™ safety relay modules type XPSPVT
For dynamic monitoring of hydraulic valves on
linear presses
Safety module XPSPVT is specifically designed for monitoring hydraulic safety
system valves which control the movements of potentially hazardous machines.
The operating principle of this module is explained in the circuit diagram of a
hydraulic safety system for linear presses (see below).
This hydraulic safety system features a 3 position piston which controls the up and
down stroke of the operating cylinder. The circuit is equipped with a safety valve, to
complete the redundant system. This circuit must be activated to enable the up and
down stroke of the cylinder.
If either of the 2 pistons becomes defective (for example, due to a broken spring or
to oil contamination), and the valve piston shifts from its normal position towards the
open position, the XPSPVT module will detect it and prevent resumption of the
piston stroke.
Proximity sensors integrated in the valve to detect the piston positions and
connected to the XPSPVT module must be damped when the valve coils are in the
de-energized state (zero position).
The sensor circuits of the XPSPVT module are designed to allow connection of NPN
and PNP proximity sensors or sensing components. Either 2-wire or 3-wire types can
be used.
The wiring diagram on page 2/228 shows how to connect proximity sensors.
Hydraulic safety system circuit operating on a linear press.
Monitoring of valves in position 0.
(1) 3 position hydraulic valve.
(2) 2 position hydraulic valve.
References:
page 2/249
Operating principle
Closing
Y1
Pump
(1)
S1
(2)
S3
P
A B
P T
A B
S2
Closing +
opening
Opening
Pressure
release valve
Y3
Y2
Wiring Diagrams:
page 2/250
Pressure
release valve
Dimensions:
page 2/260
0

Related parts for XPSAC3421P