C200H-TV003 Omron, C200H-TV003 Datasheet

no-image

C200H-TV003

Manufacturer Part Number
C200H-TV003
Description
THERMOCOUPLE IN/CURRENT OUT
Manufacturer
Omron
Datasheet

Specifications of C200H-TV003

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
High-resolution Analog I/O Modules
Special I/O Selection
This section describes the CS1 modules that are specially designed to handle analog, multiple-loop temperature control, Heat/Cool
control, PID control, Fuzzy Logic control, single- and multiple-axis position control, multiple-axis motion control, high-speed
counting, ID sensor control and voice notification module right on the PLC. All of these modules have independent co-processors to
handle the specialized functions to reduce the load on the CPU and keep cycle times extremely fast.
Analog I/O Modules
Analog input
units
Analog
output units
Analog I/O
unit
Temperature
sensor input
units
Analog input
units
Classification Model
Classification Model
*Note: Inputs are isolated from PLC signals for all units.
CS1W-PTS11
CS1W-PTS12
CS1W-PDC11
CS1W-AD041-V1
CS1W-AD081-V1
CS1W-PTW01
CS1W-PDC01
CS1W-PPS01
CS1W-PTR01
CS1W-PTR02
CS1W-DA041
CS1W-DA08V
CS1W-DA08C
CS1W-PMV01
CS1W-PMV02
CS1W-MAD44
CS1W-PTS01-V1
CS1W-PTS02
CS1W-PTS03
C200H-TS001
C200H-TS002
C200H-TS101
C200H-TS102
I/O
Capacity
I/O
Capacity
4 inputs
4 inputs
4 inputs
8 inputs
8 inputs
4 inputs
4 inputs
4 inputs
8 inputs
8 inputs
4 outputs
4 outputs
4 outputs
4 outputs
4 outputs
4 inputs
and
4 outputs
4 inputs
4 inputs
4 inputs
4 inputs
4 inputs
4 inputs
4 inputs
I/O
Isolation* Ranges/types
I/O
Isolation* Ranges/types
No
No
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
No
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
1 to 5 V, 0 to 5 V, 0 to 10 V,
±10 V, 4 to 20 mA
1 to 5 V, 0 to 5 V, 0 to 10 V,
±10 V, 4 to 20 mA
1 to 5 V, 4 to 20 mA
1 to 5 V, 0 to 5 V, 0 to 10 V,
±10 V, 4 to 20 mA, 0 to 20 mA
No-voltage semiconductor
input: 0 to 20,000 pulses/s,
Voltage input:
0 to 20,000 pulses/s,
Contact input:
0 to 20 pulses/s
-1 mA to 1 mA, 0 to 1 mA
-100 mA to 100 mA,
0 to 100 mV
1 to 5 V, 0 to 5 V, 0 to 10 V,
±10 V, 4 to 20 mA
1 to 5 V, 0 to 5 V, 0 to 10 V,
±10 V
4 to 20 mA
1 to 5 V, 4 to 20 mA
0 to 10 V, ±10 V, 0 to 5 V,
±5 V, 0 to 1 V, ±1 V
Inputs: 1 to 5 V, 0 to 5 V, to
10 V, ±10 V, 4 to 20 mA
Outputs: 1 to 5 V, 0 to 5 V,
0 to 10 V, ±10 V
B, E, J, K, N, R, S, T,
±80 mVDC auto range
Pt100 (JIS, DIN, ISO) JPt100
Ni508Ω
K, J
K, L
JPt100
Pt100
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII, ±100 mV
Pt100Ω (JIS, IEC),
JPt100Ω, Pt50Ω,
Ni508.4Ω
4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5,
1 to 5 V, 0 to 1.25 V, ±1.25 V
I/O
I/O
C S 1 S P E C I A L I / O M O D U L E S
1 ms/pt
1 ms/pt
100 ms/4 pts
100 ms/4 pts
100 ms/4 pts
200 ms/8 pts
200 ms/8 pts
1 ms/pt
1 ms/pt
1 ms/pt
100 ms/4 pts
100 ms/4 pts
1 ms/pt
150 ms/4 pts
100 ms/4 pts
100 ms/4 pts
4.8 s max.
4.8 s max.
4.8 s max.
4.8 s max.
2 ms/4 pts,
10 ms/2 pts
2 ms/4 pts,
10 ms/2 pts
2 ms/4 pts,
10 ms/2 pts
Conversion
Time
Conversion
Time
Scaling (±32,000), process
value alarms (HH, H, L, LL),
other features
Scaling (±32,000), process
value alarms (HH, H, L, LL),
other features
Scaling (±32,000), process
value alarms (HH, H, L, LL),
other features
Built-in power supply for
2-wire transmission device,
measured value alarms (HH,
H, L, LL), other features
Measured value alarms (HH,
H, L, LL), other features
Built-in power supply,
contact bounce filter, 4
instantaneous value alarms
Motor overdrive prevention,
measured value alarms
(H, L), other features
Measured value alarms
(H, L), other features
Output disconnection alarm,
control output answerback
input, other features
Automatic range setting,
measured value alarms
(HH, H, L, LL), other features
Remarks
Remarks
C-73
C-83
C-83
C-83
C-76
C-76
C-83
C-84
C-84
C-84
C-82
C-78
C-78
C-78
C-84
C-84
C-80
C-83
C-85
C-85
C-85
C-85
See
page
See
page

Related parts for C200H-TV003

C200H-TV003 Summary of contents

Page 1

... CS1W-PTS01-V1 4 inputs sensor input units CS1W-PTS02 4 inputs CS1W-PTS03 4 inputs C200H-TS001 4 inputs C200H-TS002 4 inputs C200H-TS101 4 inputs C200H-TS102 4 inputs High-resolution Analog I/O Modules Classification Model I/O Capacity Analog input CS1W-PTS11 4 inputs units CS1W-PTS12 4 inputs CS1W-PDC11 4 inputs *Note: Inputs are isolated from PLC signals for all units. ...

Page 2

... C200H-TC101 C200H-TC102 C200H-TC103 Heating/cooling C200H-TV001 control C200H-TV002 C200H-TV003 C200H-TV101 C200H-TV102 C200H-TV103 PID Control Modules The PID Control Modules can read analog input variables such as pressure or speed and control them via a 2-channel process controller with a PID (self-tuning) or two-point (ON/OFF) control response. The Modules have multiple-range inputs (Voltage or Current) and are available with three different types of output. ...

Page 3

... Voice Module The voice module provides audible message notification of system condition or alarms. Module Message Capacity C200H-OV001 60 messages Configuration Guidelines Remember to add all the current consumptions of basic I/O, special I/O modules, and CPU bus units to determine which power supply is appropriate. Please refer to the System Configuration section for current consumption of individual modules. ...

Page 4

Special I/O Modules Analog Input Modules CS1W-AD041-V1/AD081-V1 J Features • Wire burnout detection. • Peak--hold function. • Mean function. • Offset gain setting. Note: Analog Input Terminals are also available as DeviceNet Slaves and for Multiple I/O Terminals. Find more ...

Page 5

... Features Wire burnout detection Peak--hold function Mean function Note: 1. The C200H--AD001/AD002/AD003can also be used with the CS1. 2. Process I/O Modules are also available for analog I/O. 3. For more details and information refer to manual no. W345. Special I/O Modules Analog Input Modules ...

Page 6

Special I/O Modules Analog Output Modules CS1W-DA041/DA08V/DA08C J Features • Output limit. • Upper/lower limit alarms. • Offset gain adjustment. Note: 1. The functions provided depend on the model used. 2. Analog Output Terminals are also available as Devi- ceNet ...

Page 7

... Signal range settings Resolution Conversion speed Overall accuracy (at 25_C) Connections Features Output hold function Note: 1. The C200H--DA001/DA002/DA003/DA004can also be used with the CS1. 2. Process I/O Modules are also available for analog I/O. CS1W--DA041 CS1W--DA08V CS1 Special I/O Modules pts ...

Page 8

... One Module performs both analog input and analog out- put operations. The Module can also be used for ratio and bias processing, which can be performed on analog inputs to output the results as analog outputs. J Terminal Arrangement Note: For Terminal arrangement of C200H--MAD01 refer to manual W325. CS1 ...

Page 9

... Resolution Conversion speed Overall Inputs accuracy Outputs Connections Features Mean function Peak hold Wire burnout detection Output hold Ratio conversion C200H--MAD01 C200H Special I/O Modules pts 2 pts Yes ------ Yes Yes Yes Yes ------ Yes Yes Yes 1/4000 (inputs/outputs) 1.0 ms/pt max. (Inputs/ouputs) Voltage: ± ...

Page 10

Special I/O Modules Process I/O Modules CS1W-Pjj0j J Features Process Modules • External converters and transducers not required: greatly reduces costs, space requirements, and labor. • Input temperatures and use measured value alarms and disconnection alarms. • Input analog currents ...

Page 11

J Specifications Module name Model I/O capacity Isolated-type CS1W-PTS11 4 inputs Thermocouple Input Module (high-resolution) Isolated-type CS1W-PTS12 4 inputs Temperature Resistance Thermometer Input Module (high-resolution) Isolated-type CS1W-PDC11 4 inputs Analog Input Module (high-resolution) Isolated-type CS1W-PTS01-V1 4 inputs Thermocouple Input Module ...

Page 12

Special I/O Modules Process I/O Modules Specifications (continued) Module name Model I/O capacity Isolated-type CS1W-PDC01 4 inputs Analog Input Module Isolated-type CS1W-PPS01 4 inputs Pulse Input Module Isolated-type CS1W-PMV01 4 outputs Control Output Module Isolated-type CS1W-PMV02 4 outputs Power Voltage ...

Page 13

... C200H-TS001 C200H-TS002 C200H-TS101 C200H-TS102 J Features • Input directly from up to four temperature sensors of the same kind with one range setting. • Analog-digital conversion speed ideal for slower pro- cesses: 4.8 seconds max. for 4 points. • Line disconnection detection provided. Note: Temperature sensor terminals are also available on DeviceNet slave ...

Page 14

... Special I/O Modules Temperature Sensor Modules J Specifications Model C200H- TS001 Classification C200H Special I/O Modules Module numbers Inputs 4 pts Input Input Thermocouples Thermocouples K Yes signals Yes L --- R --- S --- T --- E --- B --- N --- W --- U --- PLII --- ±80 mV --- Resistance Resistance JPt100 --- th thermometers t PT100 --- Ni508.4Ω --- Input signal range settings ...

Page 15

... C200H-TCjjj C200H-DSC01 Data Setting Console J Features • Supports 2-loop PID control (two degrees of freedom) or ON/OFF control. • Input directly from two temperature sensors (thermo- couples platinum re- sistance thermometers (JPt00, Pt100). • Open-collector, voltage, or current outputs . • Sampling period: 500 ms. • Run/start control. ...

Page 16

... Special I/O Modules Temperature Control Modules J Specifications Classification Temperature sensor inputs C200H Special I/O Module Thermocouples ( Platinum resistance ther- mometers (JPt00, Pt100) ( 100) Data Setting Console Specifications Monitoring, setting, and changing present values, set points, alarm values, PID parameters, bank numbers, etc. ...

Page 17

... C200H-TVjjj C200H-DSC01 Data Setting Console J Features • Supports 2-loop PID control (two degrees of freedom) or ON/OFF control. • Input directly from two temperature sensors (thermo- couples platinum re- sistance thermometers (JPt00, Pt100). • Open-collector, voltage, or current outputs. • Sampling period: 500 ms. • Run/start control. ...

Page 18

... PID parameters, bank numbers, etc. C--90 Programmable Controller Heating control Cooling control output output Open-collector Open-collector (p (pulse) ) (pulse) Voltage (pulse) Current (linear) Open-collector (pulse) Voltage (pulse) Current (linear) CS1 Module numbers Model C200H-TV001 C200H-TV002 C200H-TV003 C200H-TV101 C200H-TV102 C200H-TV103 Model C200H-DSC01 ...

Page 19

... C200H-PID01/PID02/PID03 C200H-DSC01 Data Setting Console J Features • Supports 2-loop PID control (two degrees of freedom) or ON/OFF control. • Directly input analog signal. • Open-collector, voltage, or current outputs. • Sampling period: 100 ms. • Run/start control. • Manual outputs supported. • Set two internal alarms per loop. ...

Page 20

... Special I/O Modules PID Control Modules J Specifications Classifications Temperature sensor input C200H Special I mA Module Data Setting Console Specifications Monitoring, setting, and changing present values, set points, alarm values, PID parameters, bank numbers, etc. C--92 Programmable Controller Control output Module numbers ...

Page 21

... Eight inputs and 4 ouputs . • 8 conditions and 2 conclusions per rule, 128 rules total. J System Configuration IBM PC/AT or compatible C200H-FZ001 Fuzzy Logic Module Analog Output Module Analog Input Module RS-232C cable Analog inputs (to 9-pin connector) Analog outputs Use the Fuzzy Support software to create rules, member- ship functions, and other fuzzy data and transfer them to the Module after checking the knowledge ...

Page 22

... Special I/O Modules Fuzzy Logic Module J Specifications Fuzzy logic Classific Model ation i Rule form C200H C200H-FZ001 8 conditions and 2 Special conclusions I/O Module C--94 Programmable Controller Inputs Outputs Rules Data FS range Data 128 8 words 0 to 4095 4 words max. max. CS1 Module Processin ...

Page 23

... An adjustment operation function enables setting cam outputs while actually operating the controlled ma- chine. J System Configuration C200H-CP114 Cam Positioner Module Cam output C200H-DSC01 Control Data Setting panel Console Index table Motor Resolver Simulate the control functions of 48 mechanical cams to increase machine reliability and simplify setup ...

Page 24

... Special I/O Modules Cam Positioner Module J Specifications Classification Model C200H Special I/O C200H-CP114 Module C--96 Programmable Controller No. of cam Control Resolver response outputs Module speed 48 1° 800 r/min max. (16 external out- puts, 32 internal outputs) CS1 Module Resolver numbers response time 200 µ ...

Page 25

CS1W-NC113 CS1W-NC213 CS1W-NC413 CS1W-NC133 CS1W-NC233 CS1W-NC433 J Features • Simple positioning systems can be created by directly specifying operation from the CPU when required. • Positioning data is saved in interal flash memory, elimi- nating the need to maintain a ...

Page 26

Special I/O Modules Position Control Modules J Specifications Model CS1W-NC113 CS1W-NC133 Module name Position Control Module Classification CS1 Special I/O Modules Module numbers Control method Open-loop, automatic trapezoid acceleration/deceleration Control output CS1W-NCj13: Open-collector outputs signals CS1W-NCj33: Line-driver ...

Page 27

CS1W-MC221 CS1W-MC421 J Features • High--speed control axes with one Module and axes with one PLC (19 Modules x 4 axes. As- sumes that power supply Module capacity is not exceed- ed.). • ...

Page 28

... Number of programs capacity capacity Program capacity CX-Motion: Windows-based Support Software Model WS02-MCTC1-EV2 Supported MC CS1W-MC221/421, C200H-MC221, and CV500-MC221/421 Modules Applicable computer DOS, OS: Windows 95/98 or Windows NT Version 4.0 Functions Functions required for MC Module control: Creating/editing/saving/printingsystem parameters, positioning data, and MC programs; monitoring MC Module operation C--100 ...

Page 29

... CS1W-CT041 CS1W-CT021 C200H-CT021 C200H-CT001-V1 C200H-CT002 J Features • Max. input frequency = 500 kHz (see note 1). Output turns ON less than 0.5 ms after set value is reached (see note 2). • 32 bit counting range. • 2 and 4 axis operation available. • 5, 12, and 24 V line driver inputs available (5 and 12 V line driver input is only available for 1 axis with the CS1W--CT021 and 2 axes with the CS1W--CT041) ...

Page 30

... Special I/O Modules High--speed Counter Modules J Specifications Classification Number of Encoder A and B input, counters pulse input, Z signal C200H Special 1 Open-collector I/O Module Input voltage: 5 VDC, 12 VDC VDC RS-422 line driver 2 Open-collector Input voltage: 12 VDC or 24 VDC RS-422 line driver CS1 Special I/O ...

Page 31

CS1W-HCP22 CS1W-HCA22 CS1W-HIO01 J System Configuration Customizable Counter Module CS1 Counter input Analog output Encoder Motor Inverter J Available Models Model number Program g capacity i Contact input CS1W-HIO01 4 Kwords 12 inputs (24 VDC) (4 in- VDC) (4 in- ...

Page 32

Special I/O Modules Customizable Counter Modules J Specifications Model I/O All Modules: Contact inputs CS1W-HIO01, CS1W-HCP22, and CS1W-HCA22 Contact outputs CS1W-HCP22 Pulse inputs (pulse I/O) (high-speed counters) Pulse outputs CS1W-HCA22 (pulse Pulse inputs inputs and analog (high-speed counters) outputs) Analog ...

Page 33

J Specifications Item Contact Number of inputs 12 inputs inputs • 4 inputs (input bits IR 00000 to IR 00003) can be used either as interrupt inputs or normal inputs. Note Each of these 4 inputs can be set to ...

Page 34

Special I/O Modules Programmable Synchronous Serial Interface (SSI) Counter Module CS1W-CTS21 J System Configuration SSI Module CS1 Data Data SSI SSI Encoder Encoder CLK CLK J Specifications Classification SSI connection SSI data format Number of encoder data bits Clock frequency ...

Page 35

CS1W-V600C11 CS1W-V600C12 J Feature • Models available to connect to either one or two R/W heads. • High-data communications with the CPU (160 bytes/ scan) greatly reduce processing time from commu- nications with Data carriers to results. • Efficient programming ...

Page 36

Special I/O Modules ID Sensor Modules J System Configuration C--108 Programmable Controller CS1 ...

Page 37

J Specifications Item Data transfer speed Applicable RFID system Number of connectable R/W heads Commands (The number of bytes that can be specified is given in brackets) Communications processing time (See note.) Maintenance features Error detection Note: Add the data ...

Page 38

... Special I/O Modules Voice Module C200H-OV001 J Feature • Microphone jack enables live message broadcast. • Flexible message length. • Messages can be interrupted to start another mes- sage. • Messages can be recorded in phrase and word combination formats. • Status confirmation function without CPU program for faster system setup. • ...

Page 39

... Hz to 2.2 kHz when the recording time is set sec- onds.) Special I/O Modules Voice Module C200H Special I/O Module C200H-OV001 Adaptive differential pulse-coded modulation (ADPCM) 32, 48 (switch-selectable) 60 max. ...

Related keywords