CS1D-BC042D Omron, CS1D-BC042D Datasheet - Page 553

no-image

CS1D-BC042D

Manufacturer Part Number
CS1D-BC042D
Description
CS1D Dual CPU Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-BC042D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
518
Auxiliary Area Allocations
A325
A328
A330 to
A335
A339
and
A340
Words
Address
A32515
A32808
A32809
A32810
A32811
A32814
A32815
A33000
to
A33515
All
Bits
This CPU
Unit Loca-
tion Flag
Duplex/
Simplex
Mode Flag
(Duplex
CPU Sys-
tems only)
Active
CPU Unit
Location
Flag
Duplex
System
Configura-
tion Flags
Right CPU
Unit
Duplex
Recovery
Failed Flag
(Duplex
CPU Sys-
tems only)
Left CPU
Unit
Duplex
Recovery
Failed Flag
(Duplex
CPU Sys-
tems only)
Special I/O
Unit Initial-
izing Flags
Maximum
Differentia-
tion Flag
Number
Name
Indicates where this CPU Unit is
mounted. (Duplex CPU System
only)
Indicates the current mode.
A32808 is turned OFF in duplex ini-
tialization and thus cannot be used
alone to detect errors causing a
switch to Simplex Mode. Use
A32808 together with A43915 as
shown below.
The Duplex Initialization Flag is also
used for write processing in online
editing, when the initialize switch is
pressed, when processing com-
mands from communications or Pro-
gramming Devices, etc.
Indicates which CPU Unit is the
active CPU Unit.
Indicates the system configuration, CS1H CPU Units or
CS1D CPU Units.
A32810 OFF, A32811 OFF:
A32810 ON, A32811 OFF:
A32810 ON, A32811 ON:
ON: The right CPU Unit failed to
recover duplex operation in Duplex
Mode even after the error was
cleared and an attempt was made to
recover duplex operation automati-
cally.
ON: The left CPU Unit failed to
recover duplex operation in Duplex
Mode even after the error was
cleared and an attempt was made to
recover duplex operation automati-
cally.
These flags are ON while the corre-
sponding Special I/O Unit is initializ-
ing after its Special I/O Unit Restart
Bit (A50200 to A50715) is turned
from OFF to ON or the power is
turned ON.
The bits in these words correspond
to unit numbers 0 to 95 as follows:
A33000 to A33015: Units 0 to 15
A33100 to A33115: Units 16 to 31
----
A33500 to A33515: Units 80 to 95
Use these flags in the program to
prevent the Special I/O Unit’s refresh
data from being used while the Unit
is initializing. Also, IORF(097) can-
not be executed while a Special I/O
Unit is initializing.
These bits are turned OFF automati-
cally when initialization is com-
pleted.
These words contain the maximum
value of the differentiation flag num-
bers being used by differentiation
instructions.
CS1-H CPU Unit
CS1D CPU Unit for Single CPU System
CS1D CPU Unit for Duplex CPU System
Function
ON: Right side
OFF: Left side
ON: Duplex
OFF: Simplex
ON: Right CPU
Unit
OFF: Left CPU
Unit
ON: Automatic
recovery failed
OFF: Automatic
recovery suc-
cessful or switch
not made to sim-
plex operation
ON: Initializing
OFF: Not initial-
izing
(Turned OFF
automatically
after initializa-
tion.)
---
Settings
Held
Held
Held
Held
Held
See Func-
tion col-
umn.
change
Status
mode
after
---
---
---
---
Cleared
Cleared
Cleared
Status at
startup
When
power is
turned ON
When
power is
turned ON
or duplex
operation
started
When
power is
turned ON
When
duplex
operation
is recov-
ered
---
Written at
the start
of opera-
tion
Timing
Appendix B
---
---
---
---
---
---
A50200
to
A50715
A29513
settings
Related
flags,

Related parts for CS1D-BC042D