CS1W-SCU31-V1 Omron, CS1W-SCU31-V1 Datasheet
CS1W-SCU31-V1
Specifications of CS1W-SCU31-V1
Related parts for CS1W-SCU31-V1
CS1W-SCU31-V1 Summary of contents
Page 1
Modular Temperature Controller EJ1 In-panel Temperature Controller with Flexible Modular Design and Wide Integration with Host Devices • The compact modular structure enables construction of temperature systems optimally suited to the application. • Connection can be made to a Programmable ...
Page 2
Accessories (Order Separately) Current Transformer (CT) Diameter Model 5.8 dia. E54-CT1 12.0 dia. E54-CT3 G3ZA Connecting Cable Cable length Model 5 m EJ1C-CBLA050 Rail Mounting Equipment Name Model Mounting Rail PFP-100N PFP-50N Specifications Basic Unit/EJ1N-TC ■ Ratings Item Type ...
Page 3
Characteristics Indication accuracy Thermocouple input/platinum resistance thermometer input: Analog input: ±0.5% FS ±1 digit max. CT input: Hysteresis 0.1 to 999.9 EU (in units of 0.1 EU) (See note 2.) Proportional band (P) 0.1 to 999.9 EU (in units ...
Page 4
Communications Specifications Item Port B (See note 1.) Transmission path RS-485 (multipoint) connection Communications RS-485 (two-wire, half duplex) method Synchronization Start-stop synchronization method Communications CompoWay/F, Modbus (See note 4.) protocol Baud rate 9.6, 19.2, 38.4, 57.6, or 115.2 kbps ...
Page 5
Input Ranges Sensor inputs are fully universal. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected. Inputs can be set for each channel using universal inputs. Input type Platinum resistance thermometer Name Pt100 JPt100 Tem- ...
Page 6
... RS-485/RS-422: Multi-point, RS-232C: Point-to-point (See note 1.) RS-485/RS-422 (two-wire, half duplex), RS-232C Start-stop synchronization • OMRON PLC protocol (Connectable PLCs: SYSMAC CS/CJ/CP Series) • AnA/AnU CPU common commands (Connectable PLCs: MELSEC-An/AnS/FX • MC protocol (form 5) (Connectable PLCs: MELSEC-Q/QnA/QnAS Series) 9.6, 19.2, 38.4, 57.6, or 115.2 kbps ...
Page 7
HFU Unit/EJ1N-HFUB-DRT ■ Ratings Power supply voltage DeviceNet power supply EDU power supply Operating voltage range DeviceNet power supply EDU power supply Power consumption Main functions Ambient temperature range Ambient humidity range ■ Characteristics Insulation resistance Dielectric strength Vibration resistance ...
Page 8
End Unit/EJ1C-EDU ■ Ratings Power supply voltage Operating voltage range Auxiliary output Outputs (See note.) Transistor outputs Ambient temperature range Ambient humidity range Note: Auxiliary output can be allocated using the bus output allocation for each Basic Unit. ■ Characteristics ...
Page 9
Unit Configuration Example ■ Minimal Configuration Small Systems with 2 Channels or 4 Channels Communicating with the Host Device via RS-485 (CompoWay/F Protocol) • Alarms can be allocated to the auxiliary output for the End Unit. • G3ZA/G3PW outputs can ...
Page 10
... G3ZA/G3PW outputs can be used. • Distributed placement is possible by using multiple EJ1C-EDU End Units. • To connect more than one HFU, specific PLC and EJ1 models must be used. Refer to Connecting EJ1 Controllers 1 PLC on page 13. SYSMAC (OMRON PLC) RS-485 MELSEC (Mitsubishi Electric PLC) RS-422 EJ1N-HFU PWR ...
Page 11
Connection Precautions Communications Unit Number Setting • Communications unit numbers can be assigned to Basic Units and HFUs. Restrictions on the Number of Units That Can Be Connected Restrictions for HFUs • One EJ1N-HFU can manage ...
Page 12
... Connecting an EJ1 Controller 1 PLC SYSMAC CS/CJ/CP Series Name Serial Communications Units CJ1W-SCU21-V1 CJ1W-SCU31-V1 CJ1W-SCU41-V1 CS1W-SCU21-V1 (See note.) CS1W-SCU31-V1 Serial Communications Boards CS1W-SCB21-V1 (See note.) CS1W-SCB41-V1 (See note.) CPU Units CJ Series CS Series CP Series Note: Use only products manufactured on or after December 20, 1999. ...
Page 13
... A1SJ71UC24-PRF Model No. FX -232ADP 3U FX -485ADP 3U FX -232- -485-BD 3U V1.1 Model No. CJ1W-SCU31-V1 CJ1W-SCU41-V1 CS1W-SCU31-V1 CS1W-SCB41-V1 (See note.) CP Series EJ1N-HFUA-NFLK EJ1N-HFUB-NFLK Model No. Channel 2 of QJ71C24N QJ71C24N-R4 Channel 2 of A1SJ71QC24N Channel 2 of AJ71QC24N AJ71QC24N-R4 EJ1N-HFUA-NFL2 EJ1N-HFUB-NFL2 Modular Temperature Controller Channel 2 RS-422/485 RS-232C RS-422/485 ...
Page 14
Connection ■ External Connection • Functional insulation is applied between the power supply and the I/O sections. If reinforced insulation is required, connect the input and output terminals to devices without any exposed current-carrying parts or to devices with reinforced ...
Page 15
Nomenclature and Specification Settings ■ Part Names PWR 1 COM1 EJ1N-TC Operation RUN 2 COM2 ERR 3 COM3 Indicators ALM 4 OUT OPN PWR 1 RUN 2 SW1 ERR 3 ALM 4 SW1 ON SW2 6 SW2 Operation Indicators Operation ...
Page 16
Specification Settings Switch Operation • Check that the EJ1 is turned OFF before operating any switch other than pin 6 of SW2. Settings are read only when power is turned ON. • Set the switches with a small flat-blade ...
Page 17
... Temperature Controller Flashing: The copy operation failed. Meaning --- Upload/Download OFF → min max.) → OFF --- Not used. OFF Use the OMRON Configurator. ON Use universal Configurator. (EDS files supported) Upload (from Temperature Controller to DeviceNet Communications Unit) ON Download (from DeviceNet Communications Unit to Temperature Controller) OFF Simple allocation to TC2 Units ...
Page 18
Functional Upgrades Functions depend on the version that you are using. The functional upgrades are given below. Refer to the User's Manual (Cat. No. H142) for details. Version Applicable Unit Basic Units • Modbus communications can be used on port ...
Page 19
Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Temperature Controller Basic Units EJ1N-TC HFUs EJ1N-HFU@-NFL@ HFUs EJ1N-HFUB-DRT End Units EJ1C-EDU 31 31 PWR 1 COM1 PWR 1 COM1 RUN 2 EJ1N COM2 RUN 2 EJ1N- ...
Page 20
Options Current Transformer (Sold Separately) E54-CT1 E54-CT3 40@ 15 E54-CT3 Accessory • Armature Approx. 3 dia. 18 • Plug Approx. 6 dia. (22) Rail Mounting Equipment (Order Separately) DIN Rail PFP-100N 4.5 PFP-50N End Plate PFP-M ...
Page 21
Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Use a power supply that complies with the reinforced insulation specified in IEC 60664 for ...
Page 22
Precautions for Correct Use Installation 1. Do not connect the End Unit directly to an HFU. 2. Connect the End Unit to the right side of a Basic Unit. 3. Connect the HFU to the left side of the ...
Page 23
Removing the Terminal Block 1. Press down the terminal block lever. Lower the lever. 2. Pull out the terminal block. Pull out. Mounting to the DIN Rail Mounting Catch the hook located on the top of the Unit onto the ...
Page 24
I/O Devices ■ Examples of EJ1-series Temperature Controllers/Output Devices Input device/sensor Analog quantities, such as temperature, flow rate, and concentration Converters, Digital Panel Meters, Flow Meters, Infrared Thermosensors, Displacement Sensors ES1B Infrared Thermosensor ES2-HB Humidity Sensor ES2-THB Temperature/Humidity Sensor Thermocouple/Platinum ...
Page 25
CX-Thermo Support Software Ver. 4.1 EST2-2C-MV4 Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H, E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling Faster Parameter Setup, Device Adjustment, and Maintenance • Enables editing and batch-downloading parameters from a personal computer, reducing the work ...
Page 26
USB-Serial Conversion Cable E58-CIFQ1 Cable for Support Software Enables Connection Even with Temperature Controllers Not Equipped with Communications • Easily set Temperature Controller parameters by connecting the computer's USB port and an EJ1 new-model E5CN, E5AN, or E5EN. ...
Page 27
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 28
... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...