Figure 2. Static TEACH (Light Operate
(no signal)
(no signal)
(no signal)
Following
Darkest
Bargraph
Darkest
Darkest
TEACH
6 to 8
4 to 5
2 to 3
LED
Darkest Taught
Output OFF
1
Banner Engineering Corp. • Minneapolis, MN U.S.A
2nd Taught
Condition
Condition
T
T
T T T
Output OFF
Output OFF
T
T
T T T
shown)
0.8 seconds
> 2 seconds
0.8 seconds
> 2 seconds
• Press and hold Static button >
• Present Output ON condition.
• Click Static button.
• Present Output OFF condition.
• Click Static button.
0.04 seconds ≤ “Click” ≤ 0.8 seconds
2 seconds.
between taught conditions
between taught conditions
Excellent: Very stable operation.
Good: Minor sensing variables will
not affect sensing reliability.
Low: Minor sensing variables may
affect sensing reliability.
Unreliable: Consider an alternate
sensing scheme.
Sensing window size
threshold midway
threshold midway
Sensor positions
Sensor positions
Relative Signal Difference/
Manual Adjust
Manual Adjust
Manual Adjust
adjusted by
adjusted by
adjusted by
Output ON
Push Button
condition
Position
Position
sensing
Single
Recommendation
or
T
Output ON
Output ON
Lightest Taught
T
1st Taught
Condition
Condition
Output OFF
T
T
T
T
T
Most Light
(saturated
Most Light
(saturated
Most Light
(saturated
T
T
T
signal)
signal)
signal)
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
0.04 seconds ≤ T ≤ 0.8 seconds
No action required;
sensor is ready for 1st
TEACH condition.
• Present Output ON
• Single-pulse remote line.
• Present Output OFF
• Single-pulse remote line.
condition.
condition.
T
T
T
T
T
T
T
T
Static TEACH is the traditional setup method, used when two conditions can be
presented by the user. The sensor locates a single sensing threshold (the switchpoint)
midway between the two taught conditions, with the Output ON condition on one side,
and the Output OFF condition on the other (see Figure 2).
The first condition taught is the ON condition. The Output ON and OFF conditions can be
reversed by changing Light/Dark Operate status in SETUP mode (see page 8).
Static TEACH and Manual Adjust
Using Manual Adjust with Static TEACH moves the switching threshold. The lighted LED
on the bargraph will move to exhibit the received signal, relative to the switchpoint.
T
T
T
T
T
T
T
T
Remote Line
T
T
T
T
T
T
T
T
T
T
• Establishes a single switching threshold
• Threshold position is adjustable using “+” and “-” buttons (Manual Adjust)
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
1x
2x
3x
4x
5x
1x
2x
3x
4x
5x
6x
7x
Two-Point Static TEACH (Threshold)
Power LED: OFF
Output LED: ON
Status LEDs: LO & DO alternately
Bargraph: OFF
Power LED: OFF
Output LED: Flash, then OFF
Status LEDs: LO & DO alternately
Bargraph: OFF
TEACH Accepted
Power LED: ON
Bargraph: One LED flashes to show
Sensor returns to Run mode.
TEACH Unacceptable
Power LED: OFF
Bargraph: #1, 3, 5, 7 alternately flash
Sensor returns to “TEACH Output ON
condition.”
relative contrast (good
signal difference shown;
see table above)
to show failure
flashing
flashing
Result
P/N 117830 rev. E