S-35399A03-J8T2G Seiko Instruments, S-35399A03-J8T2G Datasheet - Page 21

Real Time Clock 2-wire Real Time Clock

S-35399A03-J8T2G

Manufacturer Part Number
S-35399A03-J8T2G
Description
Real Time Clock 2-wire Real Time Clock
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-35399A03-J8T2G

Supply Voltage (max)
3 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial
Supply Current
0.34 uA
Package / Case
SOP-8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Status register 1
reading
Rev.2.0
Sampling pulse
Low Power Supply Voltage Detection Circuit
Circuits Power-on and Low Power Supply Voltage Detection
The S-35399A03 has a low power supply voltage detection circuit, so that users can monitor drops in the power supply
voltage by reading the BLD flag (B1 in the status register 1). There is a hysteresis width of approx. 0.15 V (Typ.) between
detection voltage and release voltage (refer to “
detection circuit does the sampling operation only once in one sec for 15.6 ms.
If the power supply voltage decreases to the level of detection voltage (V
sampling operation stops. Once “1” is detected in the BLD flag, no sampling operation is performed even if the power
supply voltage increases to the level of release voltage or more, and “1” is held in the BLD flag. After initialization, or once
the BLD flag is read, the BLD flag is automatically set to “0” to restart the sampling operation.
If the BLD flag is “1” even after the power supply voltage is recovered, the internal circuit may be in the indefinite status. In
this case, be sure to initialize the circuit.
Figure 23 shows the changes of the POC flag and BLD flag due to V
Detection voltage
POC flag
BLD flag
BLD flag
BLD flag
reading
_00
V
DD
V
DD
15.6 mm
Figure 22 Timing of Low Power Supply Voltage Detection Circuit
1 s
Hysteresis width
0.15 V approximately
1 s
Figure 23 POC Flag and BLD Flag
Seiko Instruments Inc.
Stop
Characteristics (Typical Data)” ). The low power supply voltage
Low power supply
voltage detection
voltage
DD
fluctuation.
DET
) or less, “1” is set to the BLD flag so that
2-WIRE REAL-TIME CLOCK
Release voltage
Stop
Low power supply
voltage detection
voltage
S-35399A03
Stop
V
21
SS

Related parts for S-35399A03-J8T2G